The ECL15US24-E by XP Power is an active enclosed AC/DC converter providing a single 24V output at 630mA, capable of delivering 15W total power from a universal 85 ~ 264 VAC input. It is RoHS3 compliant and certified to CSA, EN, IEC, and UL standards under 62368-1. Given supply constraints, approval requirements, or application integration needs, identifying alternative models with identical key electrical and mechanical parameters ensures uninterrupted sourcing for ITE (Commercial) applications.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Number of Outputs | Type | Package / Case | Mounting Type | Efficiency | Operating Temperature | Size / Dimension | Product Status | RoHS Status | Approval Agency | Line Regulation | Load Regulation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECL15US24-E | 85 ~ 264 VAC | 24V | 630mA | 15 W | 1 | Enclosed | 4-DIP Module | Through Hole | 82% | -20°C ~ 70°C (With Derating) | 2.56" L x 1.31" W x 0.96" H | Active | ROHS3 Compliant | CSA, EN, IEC, UL | ±0.5% | ±1% |
| IRM-15-24 | 85 ~ 305 VAC, 120 ~ 430 VDC | 24V | 630mA | 15 W | 1 | Enclosed | 4-DIP Module | Through Hole | 83% | -30°C ~ 70°C (With Derating) | 2.06" L x 1.07" W x 0.94" H | Active | ROHS3 Compliant | CB, CE, cURus, TUV | ±0.3% | ±0.5% |
Substitute Part Grouping Explanation
Substitute selection is determined strictly by matching the allowed electrical and mechanical specifications: voltage input range, output voltage, output current, total output power, number of outputs, converter type, mounting style, package/case format, efficiency, operating temperature range, product status, RoHS compliance, approval/certification, and regulation parameters. Enclosed AC/DC converters with equivalent or better values on all listed parameters can be considered direct substitutes.
Parameter Comparison
| Part Number | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Type | Number of Outputs | Mounting Type | Package / Case | Efficiency | Operating Temperature | RoHS Status | Product Status | Approval Agency | Line Regulation | Load Regulation | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECL15US24-E | 85 ~ 264 VAC | 24V | 630mA | 15 W | Enclosed | 1 | Through Hole | 4-DIP Module | 82% | -20°C ~ 70°C (With Derating) | ROHS3 Compliant | Active | CSA, EN, IEC, UL | ±0.5% | ±1% | 2.56" L x 1.31" W x 0.96" H |
| IRM-15-24 | 85 ~ 305 VAC, 120 ~ 430 VDC | 24V | 630mA | 15 W | Enclosed | 1 | Through Hole | 4-DIP Module | 83% | -30°C ~ 70°C (With Derating) | ROHS3 Compliant | Active | CB, CE, cURus, TUV | ±0.3% | ±0.5% | 2.06" L x 1.07" W x 0.94" H |
Engineering Selection Recommendations
The ECL15US24-E and IRM-15-24 are both active, RoHS3 compliant enclosed AC/DC converters with through-hole mounting, a single 24V/630mA output at 15W, and comparable regulation specifications. Both are approved by recognized safety agencies and maintain universal input capability. Selection may be based on compliance alignment and desired certifications, as both meet strict regulatory requirements for ITE (Commercial) applications. Product status for both listed models is active.
Frequently Asked Questions (FAQ)
Q: What defines a direct substitute for the ECL15US24-E in enclosed AC/DC converter selection?
A: Matches are defined by identical output voltage, output current, output power, converter type, number of outputs, package/case style, mounting type, efficiency, temperature range, product status, RoHS compliance, and appropriate certifications.
Q: Are mechanical dimensions and package formats strictly compatible between the ECL15US24-E and IRM-15-24?
A: Both use a 4-DIP Module with through-hole mounting; their dimensions differ slightly. Evaluate footprint and installation parameters in the application context.
Q: Which electrical parameters must be matched for substitution?
A: Input voltage range, output voltage, maximum output current, output power, line and load regulation, and efficiency values must align with the application requirements.
Q: How do certification or approval agencies influence substitution decisions?
A: Substitution requires certifications consistent with application and regulatory standards; refer to the listed approval agencies for each part.
Q: Is RoHS3 compliance required for substitution?
A: RoHS3 compliance is a key matching parameter. Both listed models are RoHS3 compliant.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts