Part Overview
The Cincon Electronics EC3B11 is an isolated module DC-DC converter, offering 1 output of 5V at 1.5A, with an input voltage range of 18V to 36V and a maximum output power of 7.5W. The product has an obsolete status, making it necessary to identify alternative models with matching electrical and mechanical characteristics for design continuity and supply assurance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EC3B11 | Cincon Electronics Co. LTD | EC3B (7.5W) | Obsolete | Isolated Module | 1 | 18V | 36V | 5V | 1.5A | 7.5W | 1.5 kV | ITE (Commercial) | SCP | -25°C ~ 71°C | 78% | Through Hole | 5-DIP Module | 2.00" L x 1.00" W x 0.40" H | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution logic is strictly based on matching the following key parameters between EC3B11 and substitute models: voltage input range, output voltage, output current, output power, isolation voltage, application type, features, mounting type, package/case, compliance status, and moisture sensitivity level. Substitute parts must precisely align with these specifications to ensure compatibility.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EC3B11 | Cincon Electronics Co. LTD | EC3B (7.5W) | Obsolete | Isolated Module | 1 | 18V | 36V | 5V | 1.5A | 7.5W | 1.5 kV | ITE (Commercial) | SCP | -25°C ~ 71°C | 78% | Through Hole | 5-DIP Module | 2.00" L x 1.00" W x 0.40" H | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
| EC6A11 | Cincon Electronics Co. LTD | EC6A (7.5W) | Active | Isolated Module | 1 | 18V | 36V | 5V | 1.5A | 7.5W | 1.5 kV | ITE (Commercial) | SCP | -40°C ~ 100°C (With Derating) | 83% | Through Hole | 24-DIP Module, 14 Leads | 1.25" L x 0.80" W x 0.40" H | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
When selecting substitute parts for EC3B11, the product status must be considered. EC3B11 is obsolete, whereas EC6A11 is active and available. Both parts maintain ROHS3 compliance and REACH unaffected status, and share the ECCN and HTSUS codes. Compliance and recognized certifications, as provided, support valid selection within commercial ITE applications requiring these standards.
Frequently Asked Questions (FAQ)
Q1: Which key parameters must match to substitute EC3B11?
A1: Allowed electrical and mechanical parameters include voltage input range, output voltage, output current, output power, isolation voltage, application type, features, mounting type, package/case, size/dimension, compliance status, and moisture sensitivity level.
Q2: Are EC3B11 and EC6A11 compatible in terms of form factor and mounting?
A2: Both are through-hole, isolated modules, but package/case and physical dimensions differ. EC3B11 uses a 5-DIP Module (2.00" x 1.00" x 0.40"), while EC6A11 uses a 24-DIP Module, 14 Leads (1.25" x 0.80" x 0.40"). Mechanical compatibility depends strictly on provided package dimensions and lead configuration.
Q3: Is there any difference in compliance status or certifications?
A3: Both parts are ROHS3 compliant and REACH unaffected. EC6A11 includes CE and cURus approvals and Standard Number 60950-1. Certifications provided should be reviewed for compatibility with end application requirements.
Q4: Does the operating temperature range impact substitution?
A4: EC6A11 offers a wider operating temperature range (-40°C ~ 100°C with derating) compared to EC3B11 (-25°C ~ 71°C). Ensure that the substitute meets system operational requirements as per specified ranges.
Q5: Can EC6A11 directly replace EC3B11 in existing designs?
A5: Electrical specifications align based on input voltage, output voltage, output current, output power, and isolation. Substitute consideration must adhere strictly to mechanical and compliance parameters present in the input.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts