Omron E52-P75C D=10 Equivalent & Substitute Parts

Part Overview

The Omron E52-P75C D=10 is a Pt100 platinum resistance temperature sensor designed for industrial temperature measurement applications across a wide range from -200°C to 450°C. This sensor features a 3-conductor system with enclosed terminals and a 750mm protective tube with 10mm diameter. The product is currently listed as obsolete, making identification of compatible substitute parts essential for system maintenance and component replacement in existing installations.

Substiute Parts

E52-P75C D=10
Omron Automation and SafetyIn Stock: 1135E52-P75C D=10 Datasheet
E52-P75C D=10
Current Part
E52-P75C-N D=10
Omron Automation and SafetyIn Stock: 1112E52-P75C-N D=10 Datasheet
E52-P75C-N D=10
Similar

Key Parameters

Parameter Value
Manufacturer Part Number E52-P75C D=10
Manufacturer Omron Automation and Safety
Category Temperature Sensors
Element Type Pt100
Temperature Range -200°C ~ 450°C
Conductor Type 3 Conductor System
Terminal Type Enclosed Terminals
Length - Protective Tube 750mm
Diameter - Protective Tube 10mm
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 9032.89.6040

Substitute Part Grouping Explanation

Substitution compatibility for the E52-P75C D=10 is determined by the following critical parameters:

  • Element Type: Pt100 platinum resistance thermometer
  • Temperature Range: -200°C ~ 450°C operational capability
  • Conductor Configuration: 3-conductor system for RTD signal transmission
  • Terminal Interface: Enclosed terminals for connection compatibility
  • Protective Tube Dimensions: 750mm length and 10mm diameter for mechanical fit
  • Manufacturer Consistency: Omron Automation and Safety product line

The substitute part E52-P75C-N D=10 maintains identical specifications across all these critical parameters, ensuring functional and mechanical compatibility with the original component.

Parameter Comparison

Parameter E52-P75C D=10 (Main Part) E52-P75C-N D=10 (Substitute)
Manufacturer Omron Automation and Safety Omron Automation and Safety
Series E52 E52
Element Type Pt100 Pt100
Temperature Range -200°C ~ 450°C -200°C ~ 450°C
Conductor Type 3 Conductor System 3 Conductor System
Terminal Type Enclosed Terminals Enclosed Terminals
Length - Protective Tube 750mm 750mm
Diameter - Protective Tube 10mm 10mm
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 9032.89.6040 9032.89.6040
Product Status Obsolete Active
Packaging - Bulk

Engineering Selection Recommendations

The E52-P75C-N D=10 is the direct substitute for the obsolete E52-P75C D=10. Both components share identical electrical and mechanical specifications, including Pt100 element type, temperature measurement range, 3-conductor configuration, and protective tube dimensions. The substitute part maintains active product status with Omron, ensuring continued availability and supply chain reliability. Both components carry identical export classification (ECCN: EAR99) and tariff codes (HTSUS: 9032.89.6040), confirming regulatory equivalence. The transition from the obsolete to the active part number involves only a packaging designation change (from unspecified to Bulk), with no impact on component functionality or performance characteristics.

Frequently Asked Questions (FAQ)

Q: Can the E52-P75C-N D=10 directly replace the E52-P75C D=10 in existing installations?

A: Yes. Both components are Pt100 temperature sensors with identical temperature ranges (-200°C ~ 450°C), 3-conductor systems, enclosed terminals, and 750mm × 10mm protective tube dimensions. The substitute maintains full functional and mechanical compatibility.

Q: What is the difference between the main part and the substitute?

A: The primary difference is product status. The E52-P75C D=10 is obsolete, while the E52-P75C-N D=10 is active. The substitute also specifies Bulk packaging. All electrical and mechanical parameters remain identical.

Q: Are there any compliance or certification differences?

A: No. Both components carry identical ECCN (EAR99) and HTSUS (9032.89.6040) classifications, confirming regulatory equivalence.

Q: Does the packaging change from unspecified to Bulk affect component performance?

A: No. Packaging designation does not affect the sensor's electrical performance, temperature measurement accuracy, or mechanical fit. It reflects only the distribution format.

Q: Why is the original part listed as obsolete?

A: Product obsolescence typically reflects manufacturer discontinuation decisions. The active substitute E52-P75C-N D=10 provides continued access to equivalent Pt100 temperature sensing capability within the E52 series.

Request Quote (Ships tomorrow)