Omron E52-P35C D=10 Temperature Sensor - Equivalent & Substitute Parts

Part Overview

The Omron E52-P35C D=10 is a Pt100 resistance temperature detector (RTD) designed for industrial temperature measurement applications across a range of -200°C to 450°C. This sensor features a 3-conductor system with enclosed terminals, a 350mm protective tube, and a 10mm tube diameter. The part is currently listed as obsolete, making identification of functionally equivalent alternatives essential for system maintenance and component procurement.

Substiute Parts

E52-P35C D=10
Omron Automation and SafetyIn Stock: 864E52-P35C D=10 Datasheet
E52-P35C D=10
Current Part
E52-P35C-N D=10
Omron Automation and SafetyIn Stock: 853E52-P35C-N D=10 Datasheet
E52-P35C-N D=10
Similar

Key Parameters

Parameter Value
Manufacturer Part Number E52-P35C D=10
Manufacturer Omron Automation and Safety
Category Temperature Sensors
Element Type Pt100
Temperature Range -200°C ~ 450°C
Conductor Type 3 Conductor System
Terminal Type Enclosed Terminals
Length - Protective Tube 350mm
Diameter - Protective Tube 10mm
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

The E52-P35C-N D=10 qualifies as a direct substitute based on matching electrical and mechanical specifications. Substitution eligibility is determined by the following critical parameters:

  • Element Type: Both parts use Pt100 RTD elements
  • Temperature Range: Identical range of -200°C to 450°C
  • Conductor Type: Both employ 3-conductor system configuration
  • Terminal Type: Both feature enclosed terminals
  • Protective Tube Dimensions: Matching 350mm length and 10mm diameter
  • Moisture Sensitivity Level: Both rated MSL 1 (Unlimited)

The primary distinction between the main part and substitute is product status: the E52-P35C D=10 is obsolete, while the E52-P35C-N D=10 maintains active status with current manufacturing support.

Parameter Comparison

Parameter E52-P35C D=10 E52-P35C-N D=10
Manufacturer Omron Automation and Safety Omron Automation and Safety
Category Temperature Sensors Temperature Sensors
Element Type Pt100 Pt100
Temperature Range -200°C ~ 450°C -200°C ~ 450°C
Conductor Type 3 Conductor System 3 Conductor System
Terminal Type Enclosed Terminals Enclosed Terminals
Length - Protective Tube 350mm 350mm
Diameter - Protective Tube 10mm 10mm
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Product Status Obsolete Active
ECCN EAR99 EAR99

Engineering Selection Recommendations

The E52-P35C-N D=10 is the appropriate substitute for the obsolete E52-P35C D=10. Both parts share identical electrical and mechanical specifications, ensuring functional compatibility in existing applications. The substitute part maintains active product status with current manufacturing availability, eliminating supply chain constraints associated with obsolete components. Both parts carry equivalent export compliance classifications (ECCN EAR99) and moisture sensitivity ratings, supporting direct replacement in regulated environments.

Frequently Asked Questions (FAQ)

Q: Can the E52-P35C-N D=10 directly replace the E52-P35C D=10 in existing installations?

A: Yes. Both parts are electrically and mechanically identical, featuring the same Pt100 element, temperature range (-200°C to 450°C), 3-conductor configuration, enclosed terminals, and protective tube dimensions (350mm length, 10mm diameter). Direct substitution is supported without circuit or mechanical modifications.

Q: What is the primary reason for substitution?

A: The E52-P35C D=10 is obsolete and no longer manufactured. The E52-P35C-N D=10 is the active equivalent part with current production and supply availability.

Q: Are there packaging differences between these parts?

A: The main part number does not specify packaging details. The substitute part is supplied in bulk packaging. Confirm packaging requirements with your procurement specifications.

Q: Do both parts meet the same compliance standards?

A: Yes. Both parts carry identical ECCN classification (EAR99) and MSL rating (1 - Unlimited), supporting use in equivalent regulatory and environmental contexts.

Q: What parameters must remain constant for substitution eligibility?

A: Pt100 element type, -200°C to 450°C temperature range, 3-conductor system, enclosed terminals, 350mm protective tube length, and 10mm tube diameter are the critical parameters determining substitution compatibility.

Request Quote (Ships tomorrow)