Request Quote
(Ships tomorrow)
E52-P20C D=3.2 Equivalent & Substitute Parts
Part Overview
The Omron E52-P20C D=3.2 is a Pt100 resistance temperature detector (RTD) designed for industrial temperature measurement applications across a 0–400°C range. This component features a 3-conductor system with enclosed terminals, a 200mm protective tube, and a 3.2mm diameter housing. The part is currently listed as obsolete, making identification of functionally equivalent alternatives essential for system maintenance, repair, and new design implementations where this sensor specification remains required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | E52-P20C D=3.2 |
| Manufacturer | Omron Automation and Safety |
| Category | Temperature Sensors |
| Element Type | Pt100 |
| Temperature Range | 0–400°C |
| Conductor Type | 3 Conductor System |
| Terminal Type | Enclosed Terminals |
| Length - Protective Tube | 200mm |
| Diameter - Protective Tube | 3.2mm |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the E52-P20C D=3.2 is determined by strict equivalence across the following critical parameters:
- Element Type: Must be Pt100 RTD
- Temperature Range: Must support 0–400°C operation
- Conductor Configuration: Must be 3-conductor system
- Terminal Interface: Must feature enclosed terminals
- Physical Dimensions: Protective tube length of 200mm and diameter of 3.2mm must be maintained
- Regulatory Compliance: REACH and ECCN classifications must be compatible
The substitute part E52-P20C-N D=3.2 meets all these criteria and represents the active-status equivalent within the Omron E52 series.
Parameter Comparison
| Parameter | E52-P20C D=3.2 (Main) | E52-P20C-N D=3.2 (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Element Type | Pt100 | Pt100 |
| Temperature Range | 0–400°C | 0–400°C |
| Conductor Type | 3 Conductor System | 3 Conductor System |
| Terminal Type | Enclosed Terminals | Enclosed Terminals |
| Length - Protective Tube | 200mm | 200mm |
| Diameter - Protective Tube | 3.2mm | 3.2mm |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| Product Status | Obsolete | Active |
| ECCN | EAR99 | EAR99 |
Engineering Selection Recommendations
The E52-P20C-N D=3.2 is the direct functional equivalent for applications currently using the obsolete E52-P20C D=3.2. Both components share identical electrical and mechanical specifications, including Pt100 element type, 3-conductor configuration, enclosed terminal design, and 0–400°C temperature range. The substitute part maintains the same protective tube dimensions (200mm length, 3.2mm diameter) and regulatory compliance profile (REACH unaffected, EAR99 classification).
The primary distinction is product status: the E52-P20C-N D=3.2 is actively manufactured and supported, whereas the original part is obsolete. For new designs, system upgrades, or component replacement in existing installations, the E52-P20C-N D=3.2 provides continuity of function with assured supply chain availability.
Frequently Asked Questions (FAQ)
Q: Can the E52-P20C-N D=3.2 be used as a direct replacement for the E52-P20C D=3.2?
A: Yes. Both components are functionally identical across all critical parameters: Pt100 element, 3-conductor system, enclosed terminals, 0–400°C temperature range, and 200mm × 3.2mm protective tube dimensions. The substitute is the active-production equivalent.
Q: What is the difference between these two part numbers?
A: The E52-P20C-N D=3.2 is the current production variant of the E52-P20C D=3.2 series. The "-N" designation and active product status indicate manufacturing continuity. Electrical and mechanical performance are equivalent.
Q: Are there packaging differences between these parts?
A: The original part is listed with unspecified packaging, while the substitute is supplied in bulk packaging. This does not affect component functionality or electrical characteristics.
Q: What does the "D=3.2" designation indicate?
A: The "D=3.2" specifies the outer diameter of the protective tube in millimeters. This dimension is critical for mechanical fit in thermowell installations and sensor mounting assemblies.
Q: Is the E52-P20C-N D=3.2 compliant with the same regulatory standards?
A: Yes. Both parts carry identical REACH and ECCN (EAR99) classifications, ensuring equivalent regulatory compliance for export and industrial applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts