Omron E52-P10AE 4M Pt100 Temperature Sensor - Equivalent & Substitute Parts

Part Overview

The Omron E52-P10AE 4M is a Pt100 resistance temperature detector (RTD) designed for temperature measurement applications across a range of -50°C to 250°C. This sensor features a 3-conductor system with exposed lead wires, a 100mm protective tube, and 4 meters of lead wire length. The product is currently classified as obsolete, making identification of suitable substitute components essential for ongoing system maintenance and new design implementations.

Substiute Parts

E52-P10AE 4M
Omron Automation and SafetyIn Stock: 1155E52-P10AE 4M Datasheet
E52-P10AE 4M
Current Part
E52-P10AEY 4M
Omron Automation and SafetyIn Stock: 1152E52-P10AEY 4M Datasheet
E52-P10AEY 4M
Similar

Key Parameters

Parameter Value
Manufacturer Part Number E52-P10AE 4M
Manufacturer Omron Automation and Safety
Category Temperature Sensors
Element Type Pt100
Temperature Range -50°C ~ 250°C
Lead Wire Length 13.123' (4m)
Conductor Type 3 Conductor System
Terminal Type Exposed Lead Wires
Protective Tube Length 100mm
Protective Tube Diameter 3.2mm
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the E52-P10AE 4M is determined by the following critical parameters:

  • Element Type: Must be Pt100 RTD
  • Lead Wire Length: Must be 13.123' (4m)
  • Terminal Type: Must be Exposed Lead Wires
  • Protective Tube Dimensions: Length 100mm, Diameter 3.2mm
  • Moisture Sensitivity Level: Must be MSL 1 (Unlimited)

The E52-P10AEY 4M qualifies as a substitute based on matching these core parameters. However, the temperature range differs: the substitute operates from 0°C to 250°C versus the original -50°C to 250°C. Additionally, the substitute uses a non-grounded conductor configuration compared to the original 3-conductor system. These differences must be evaluated against specific application requirements.

Parameter Comparison

Parameter E52-P10AE 4M (Original) E52-P10AEY 4M (Substitute)
Manufacturer Part Number E52-P10AE 4M E52-P10AEY 4M
Manufacturer Omron Automation and Safety Omron Automation and Safety
Element Type Pt100 Pt100
Temperature Range -50°C ~ 250°C 0°C ~ 250°C
Lead Wire Length 13.123' (4m) 13.123' (4m)
Conductor Type 3 Conductor System Non-Grounded
Terminal Type Exposed Lead Wires Exposed Lead Wires
Protective Tube Length 100mm 100mm
Protective Tube Diameter 3.2mm 3.2mm
Product Status Obsolete Active
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The E52-P10AEY 4M is the designated substitute for the obsolete E52-P10AE 4M. Selection of this substitute is appropriate when the application temperature range does not require operation below 0°C. The substitute maintains active product status with Omron, ensuring ongoing availability and supply chain continuity.

For applications requiring operation at temperatures below 0°C, the lower temperature limit of the substitute (-50°C minimum on the original) represents a functional limitation. In such cases, alternative Pt100 sensors with equivalent mechanical specifications and extended low-temperature capability must be sourced.

The transition from a 3-conductor to non-grounded conductor configuration affects signal conditioning and noise immunity characteristics. System integration must account for this electrical difference in measurement circuit design.

Frequently Asked Questions (FAQ)

Q: Can the E52-P10AEY 4M directly replace the E52-P10AE 4M in all applications?

A: Direct replacement is possible only when the application does not require temperature measurement below 0°C. The substitute's minimum operating temperature is 0°C, compared to -50°C for the original. Additionally, the conductor configuration differs, requiring evaluation of measurement circuit compatibility.

Q: What is the significance of the conductor type difference between these parts?

A: The original E52-P10AE 4M uses a 3-conductor system, while the substitute E52-P10AEY 4M is non-grounded. This affects how the RTD connects to measurement instrumentation and influences noise rejection in the measurement circuit. System design must accommodate this electrical difference.

Q: Are both parts manufactured by the same company?

A: Yes, both the E52-P10AE 4M and E52-P10AEY 4M are manufactured by Omron Automation and Safety. The substitute is an active product, whereas the original is obsolete.

Q: Do these sensors have identical physical dimensions?

A: Yes, both sensors share identical protective tube specifications: 100mm length and 3.2mm diameter. Lead wire length is also identical at 4 meters (13.123 feet).

Q: What does MSL 1 (Unlimited) mean for these components?

A: Moisture Sensitivity Level 1 (Unlimited) indicates that these sensors have no moisture sensitivity restrictions and do not require special handling or storage conditions related to humidity exposure.