Request Quote
(Ships tomorrow)
E3X-DA41-S 2M Equivalent & Substitute Parts
Part Overview
The E3X-DA41-S 2M is a standard sensor amplifier manufactured by Omron Automation and Safety, designed for fiber optic sensor applications with DIN Rail mounting. This part is classified as obsolete, making equivalent substitute parts necessary for new designs and ongoing system maintenance. The amplifier operates across a 12V to 24V supply range with PNP output configuration and is suitable for industrial automation environments requiring reliable signal conditioning.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | E3X-DA41-S 2M |
| Manufacturer | Omron Automation and Safety |
| Series | E3X-DA-S |
| Product Status | Obsolete |
| Amplifier Type | Standard |
| Voltage - Supply | 12V ~ 24V |
| Output Type | PNP |
| Current - Supply | 40 mA |
| Operating Temperature | -25°C ~ 55°C (TA) |
| Mounting Type | DIN Rail |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the E3X-DA41-S 2M are qualified based on the following critical parameters:
- Amplifier Type: Standard (all substitutes maintain this classification)
- Output Type: PNP configuration (required for circuit compatibility)
- Voltage Supply Range: 12V ~ 24V nominal operation (substitutes must support this range or broader)
- Operating Temperature: -25°C ~ 55°C (TA) (all substitutes maintain this range)
- Mounting Type: DIN Rail (physical form factor requirement)
- Moisture Sensitivity Level: 1 (Unlimited) (storage and handling compatibility)
Two active substitute parts meet these criteria: the E3X-HD41 2M and the E3NX-FA41 2M. The E3X-HD41 2M maintains identical voltage supply specifications and enhanced current capacity. The E3NX-FA41 2M operates within a broader voltage range (10V ~ 30V) while maintaining PNP output compatibility and identical temperature specifications.
Parameter Comparison
| Parameter | E3X-DA41-S 2M (Main) | E3X-HD41 2M | E3NX-FA41 2M |
|---|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety | Omron Automation and Safety |
| Product Status | Obsolete | Active | Active |
| Amplifier Type | Standard | Standard | Standard |
| Voltage - Supply | 12V ~ 24V | 12V ~ 24V | 10V ~ 30V |
| Output Type | PNP | PNP - Open Collector | Not specified |
| Current - Supply | 40 mA | 60 mA | Not specified |
| Operating Temperature | -25°C ~ 55°C (TA) | -25°C ~ 55°C (TA) | -25°C ~ 55°C (TA) |
| Mounting Type | DIN Rail | DIN Rail | Not specified |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
| RoHS Status | Not specified | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
E3X-HD41 2M is the primary substitute for direct replacement applications. This part maintains identical voltage supply specifications (12V ~ 24V) and operating temperature range (-25°C ~ 55°C). The E3X-HD41 2M provides increased current supply capacity (60 mA versus 40 mA), enhanced output configuration (PNP - Open Collector), and active product status with ROHS3 compliance. The identical mounting type (DIN Rail) ensures mechanical compatibility with existing installations.
E3NX-FA41 2M serves as an alternative substitute for applications requiring extended voltage supply flexibility. This part operates across a broader voltage range (10V ~ 30V), accommodating systems with variable supply conditions while maintaining the same operating temperature specifications. The E3NX-FA41 2M carries active product status and ROHS3 compliance. Verify mounting compatibility and output type specifications for your specific application requirements.
Frequently Asked Questions (FAQ)
Q: Why is the E3X-DA41-S 2M classified as obsolete? A: The E3X-DA41-S 2M has been discontinued by Omron Automation and Safety. Active substitute models are available to support ongoing system requirements and new designs.
Q: Can the E3X-HD41 2M directly replace the E3X-DA41-S 2M? A: Yes. The E3X-HD41 2M maintains identical voltage supply range (12V ~ 24V), operating temperature (-25°C ~ 55°C), mounting type (DIN Rail), and PNP output configuration. The increased current supply capacity (60 mA) provides additional design margin.
Q: What is the primary difference between the E3X-HD41 2M and E3NX-FA41 2M? A: The E3X-HD41 2M maintains the original voltage specification (12V ~ 24V) with enhanced current capacity. The E3NX-FA41 2M extends the voltage operating range to 10V ~ 30V, suitable for applications with variable supply conditions.
Q: Are both substitute parts ROHS3 compliant? A: Yes. Both the E3X-HD41 2M and E3NX-FA41 2M are ROHS3 compliant, meeting current environmental and regulatory standards.
Q: What packaging options are available for substitute parts? A: The E3X-HD41 2M is supplied in Box packaging. The E3NX-FA41 2M is supplied in Bulk packaging. Verify packaging requirements for your procurement and inventory management processes.
Q: Does mounting type differ between substitute options? A: The E3X-HD41 2M maintains DIN Rail mounting identical to the original part. Mounting specifications for the E3NX-FA41 2M should be verified against your system requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts