Omron E2E-C1C1-R Inductive Proximity Sensor - Equivalent & Substitute Parts

Part Overview

The Omron E2E-C1C1-R is a cylindrical inductive proximity sensor designed for non-contact object detection in industrial automation applications. This sensor operates with a 1mm sensing distance and provides NPN normally-open output through a 3-wire configuration. The product is classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance, repair, and component sourcing in ongoing production environments.

Substiute Parts

E2E-C1C1-R
Omron Automation and SafetyIn Stock: 1047E2E-C1C1-R Datasheet
E2E-C1C1-R
Current Part
E2E-C04S12-MC-C1
Omron Automation and SafetyIn Stock: 862E2E-C04S12-MC-C1 Datasheet
E2E-C04S12-MC-C1
Similar

Key Parameters

Parameter Value
Manufacturer Part Number E2E-C1C1-R
Manufacturer Omron Automation and Safety
Series E2E
Product Status Obsolete
Sensor Type Inductive
Sensing Distance 0.039" (1mm)
Output Type NPN-NO, 3-Wire
Response Frequency 3kHz
Shielding Shielded
Material - Body Nickel-Plated Brass
Voltage - Supply 10V ~ 30V
Termination Style Cable Leads
Operating Temperature -25°C ~ 70°C
Ingress Protection IP67
Indicator LED
Package / Case Cylinder
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8543.70.9860

Substitute Part Grouping Explanation

The E2E-C04S12-MC-C1 is identified as a functionally equivalent substitute for the obsolete E2E-C1C1-R based on the following critical parameters:

Matching Parameters:

  • Sensor Type: Inductive
  • Output Type: NPN-NO, 3-Wire
  • Shielding: Shielded
  • Voltage Supply Range: 10V ~ 30V
  • Operating Temperature Range: -25°C ~ 70°C
  • Ingress Protection: IP67
  • Indicator: LED
  • Package / Case: Cylinder
  • Series: E2E
  • ECCN: EAR99
  • HTSUS: 8543.70.9860

Differing Parameters:

  • Sensing Distance: 1.2mm (vs. 1mm in original)
  • Response Frequency: 4kHz (vs. 3kHz in original)
  • Material - Body: Stainless Steel (vs. Nickel-Plated Brass in original)
  • Termination Style: Connector (vs. Cable Leads in original)
  • Product Status: Active (vs. Obsolete in original)

The substitute maintains electrical compatibility and environmental specifications while offering improved material durability and an active product status for ongoing availability.

Parameter Comparison

Parameter E2E-C1C1-R (Main) E2E-C04S12-MC-C1 (Substitute)
Manufacturer Part Number E2E-C1C1-R E2E-C04S12-MC-C1
Product Status Obsolete Active
Sensor Type Inductive Inductive
Sensing Distance 0.039" (1mm) 0.047" (1.2mm)
Output Type NPN-NO, 3-Wire NPN-NO, 3-Wire
Response Frequency 3kHz 4kHz
Shielding Shielded Shielded
Material - Body Nickel-Plated Brass Stainless Steel
Voltage - Supply 10V ~ 30V 10V ~ 30V
Termination Style Cable Leads Connector
Operating Temperature -25°C ~ 70°C -25°C ~ 70°C
Ingress Protection IP67 IP67
Indicator LED LED
Package / Case Cylinder Cylinder
ECCN EAR99 EAR99
HTSUS 8543.70.9860 8543.70.9860

Engineering Selection Recommendations

The E2E-C04S12-MC-C1 is the designated substitute for the obsolete E2E-C1C1-R. Selection of this substitute is based on:

  • Product Status: The substitute maintains active product status, ensuring continued availability and supply chain reliability.
  • Electrical Compatibility: Both sensors operate within the same voltage supply range (10V ~ 30V) and provide identical NPN-NO, 3-wire output configuration, enabling direct functional replacement in existing circuits.
  • Environmental Specifications: Identical operating temperature range (-25°C ~ 70°C) and IP67 ingress protection rating ensure equivalent performance in industrial environments.
  • Export Classification: Both parts share the same ECCN (EAR99) and HTSUS codes, maintaining regulatory compliance for international distribution.

The 0.2mm increase in sensing distance (1.2mm vs. 1mm) and the change from cable leads to connector termination require mechanical and installation verification in the target application. The stainless steel body material of the substitute provides enhanced corrosion resistance compared to the nickel-plated brass of the original part.

Frequently Asked Questions (FAQ)

Q: Can the E2E-C04S12-MC-C1 directly replace the E2E-C1C1-R in all applications?

A: The substitute provides electrical and environmental compatibility. However, the 0.2mm difference in sensing distance and the change from cable leads to connector termination require verification against specific application requirements. Mechanical mounting and wiring interface must be confirmed before implementation.

Q: What is the significance of the sensing distance difference between the two sensors?

A: The E2E-C1C1-R operates at 1mm sensing distance, while the E2E-C04S12-MC-C1 operates at 1.2mm. This 0.2mm difference affects the maximum distance at which the sensor detects ferrous metal objects. Applications with tight spatial constraints or precise detection requirements must account for this parameter variation.

Q: Why does the substitute use a connector termination instead of cable leads?

A: The E2E-C04S12-MC-C1 employs connector-based termination, whereas the original E2E-C1C1-R uses cable leads. This design change requires compatible connector hardware and may necessitate modifications to existing wiring harnesses or connection infrastructure.

Q: Are there compliance or certification differences between these sensors?

A: Both sensors share identical ECCN (EAR99) and HTSUS classifications. The substitute is RoHS non-compliant, which should be evaluated against your system's regulatory requirements.

Q: What is the response frequency difference, and does it affect substitution suitability?

A: The E2E-C04S12-MC-C1 operates at 4kHz response frequency compared to the 3kHz of the E2E-C1C1-R. This 1kHz increase provides faster detection response and is generally compatible with applications designed for the original 3kHz specification.

Request Quote (Ships tomorrow)