Request Quote
(Ships tomorrow)
Omron E2C-EV05 Inductive Proximity Sensor Equivalent & Substitute Parts
Part Overview
The Omron E2C-EV05 is an inductive proximity sensor designed for non-contact detection applications requiring a 5mm (0.197") sensing distance with IP67 ingress protection. This sensor operates as a modular unit with cable lead termination and is constructed with a zinc die-cast body for durability in industrial environments.
The E2C-EV05 is classified as obsolete. Locating equivalent or substitute components is necessary to maintain system functionality and ensure continued availability for replacement or new installations where this sensor specification is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Omron Automation and Safety |
| Series | E2C |
| Sensor Type | Inductive |
| Sensing Distance | 0.197" (5mm) |
| Output Type | Requires Amplifier |
| Shielding | Shielded |
| Material - Body | Zinc Die-Cast |
| Termination Style | Cable Leads |
| Operating Temperature | -10°C ~ 60°C |
| Ingress Protection | IP67 |
| Package / Case | Module |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the E2C-EV05 is determined by the following critical parameters that must remain consistent:
- Sensor Type: Inductive technology for ferrous metal detection
- Sensing Distance: 0.197" (5mm) detection range
- Ingress Protection: IP67 rating for sealed operation
- Package / Case: Module form factor
- Material - Body: Zinc die-cast construction
- Operating Temperature Range: -10°C ~ 60°C
- Shielding: Shielded configuration
The E2NC-EV05 is identified as the manufacturer-recommended substitute. This part maintains all critical electrical and mechanical parameters while transitioning from cable lead termination to connector-based termination. The E2NC series represents the active product line continuation within Omron's inductive proximity sensor portfolio.
Parameter Comparison
| Parameter | E2C-EV05 (Main Part) | E2NC-EV05 (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Sensor Type | Inductive | Inductive |
| Sensing Distance | 0.197" (5mm) | 0.197" (5mm) |
| Shielding | Shielded | Shielded |
| Material - Body | Zinc Die-Cast | Zinc Die-Cast |
| Operating Temperature | -10°C ~ 60°C | -10°C ~ 60°C |
| Ingress Protection | IP67 | IP67 |
| Indicator | No Indicator | No Indicator |
| Package / Case | Module | Module |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The E2NC-EV05 is the appropriate substitute for the obsolete E2C-EV05 based on the following factors:
- Product Status: The E2NC-EV05 is an active product with current manufacturing and inventory support (719 units in stock), whereas the E2C-EV05 is obsolete.
- Functional Equivalence: All critical sensing parameters—inductive detection, 5mm sensing distance, IP67 protection, and operating temperature range—are identical between the two parts.
- Compliance: Both parts maintain RoHS compliance status, ensuring regulatory alignment for industrial applications.
- Termination Transition: The primary design difference is the shift from cable lead termination to connector-based termination in the E2NC series. This change requires evaluation of the existing installation interface to confirm compatibility with connector-based connection methods.
Frequently Asked Questions (FAQ)
Q: What is the primary difference between the E2C-EV05 and E2NC-EV05?
A: The E2NC-EV05 uses connector termination instead of cable leads. Both sensors maintain identical sensing distance (5mm), IP67 protection, operating temperature range, and shielded inductive detection capability.
Q: Can the E2NC-EV05 directly replace the E2C-EV05 in existing installations?
A: Direct mechanical and electrical replacement depends on the existing termination interface. If the original installation uses cable lead connections, the connector termination of the E2NC-EV05 requires interface adaptation or rewiring.
Q: Are both sensors RoHS compliant?
A: Yes, both the E2C-EV05 and E2NC-EV05 are RoHS compliant.
Q: What is the operating temperature range for both sensors?
A: Both sensors operate within the range of -10°C to 60°C.
Q: Is the sensing distance identical between both parts?
A: Yes, both sensors provide a 0.197" (5mm) sensing distance for inductive proximity detection.
Q: What is the ingress protection rating for both sensors?
A: Both sensors are rated IP67, providing complete dust protection and temporary immersion capability.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts