DS1816-5 Equivalent & Substitute Parts

Part Overview

The DS1816-5 is a single-channel power supply supervisor IC from Analog Devices Inc./Maxim Integrated's EconoReset series, designed for power-on reset and simple reset applications. This device monitors a single voltage threshold at 3.06V and provides an active-low reset output via open drain or open collector configuration. The DS1816-5 is classified as obsolete, making identification of compatible substitute parts essential for ongoing system support and new design implementations.

Substiute Parts

DS1816-5
Analog Devices Inc./Maxim IntegratedIn Stock: 1136DS1816-5 Datasheet
DS1816-5
Current Part
DS1818-5+
Analog Devices Inc./Maxim IntegratedIn Stock: 2266DS1818-5+ Datasheet
DS1818-5+
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number DS1816-5
Manufacturer Analog Devices Inc./Maxim Integrated
Category Power Management (PMIC)
Package / Case TO-226-3, TO-92-3 (TO-226AA)
Mounting Type Through Hole
Number of Voltages Monitored 1
Voltage - Threshold 3.06V
Output Type Open Drain or Open Collector
Reset Logic Active Low
Reset Timeout 100ms Minimum
Operating Temperature Range -40°C ~ 85°C (TA)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the DS1816-5 is determined by strict equivalence across the following critical parameters:

  • Single voltage monitoring channel with 3.06V threshold
  • Open drain or open collector output configuration
  • Active-low reset logic with 100ms minimum timeout
  • Through-hole mounting in TO-92-3 package
  • Operating temperature range of -40°C to 85°C
  • EconoReset series compatibility

The DS1818-5+ meets all these criteria and serves as a parametric equivalent. The primary distinction is product status: the DS1816-5 is obsolete while the DS1818-5+ is active, along with improved RoHS compliance status.

Parameter Comparison

Parameter DS1816-5 DS1818-5+
Manufacturer Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated
Series EconoReset EconoReset
Number of Voltages Monitored 1 1
Voltage - Threshold 3.06V 3.06V
Output Type Open Drain or Open Collector Open Drain or Open Collector
Reset Logic Active Low Active Low
Reset Timeout 100ms Minimum 100ms Minimum
Operating Temperature Range -40°C ~ 85°C (TA) -40°C ~ 85°C (TA)
Package / Case TO-226-3, TO-92-3 (TO-226AA) TO-226-3, TO-92-3 (TO-226AA)
Mounting Type Through Hole Through Hole
Product Status Obsolete Active
RoHS Status RoHS non-compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8542.39.0001 8542.39.0001

Engineering Selection Recommendations

The DS1818-5+ is the direct substitute for the obsolete DS1816-5. Both devices are electrically and mechanically identical across all functional parameters. Selection of the DS1818-5+ is supported by its active product status and ROHS3 compliance, which provides regulatory advantage for new designs and ongoing production. The DS1818-5+ maintains full compatibility with existing circuit designs using the DS1816-5, requiring no modifications to PCB layouts or signal routing due to identical TO-92-3 packaging and pin configuration.

Frequently Asked Questions (FAQ)

Q: Can the DS1818-5+ be used as a direct replacement for the DS1816-5 in existing designs?

A: Yes. The DS1818-5+ is a parametric equivalent with identical electrical specifications, threshold voltage, output configuration, and package type. No circuit modifications are required.

Q: What is the primary reason to transition from DS1816-5 to DS1818-5+?

A: The DS1816-5 is obsolete. The DS1818-5+ is an active product from the same manufacturer and series, ensuring continued availability and supply chain reliability. Additionally, the DS1818-5+ meets ROHS3 compliance requirements.

Q: Are the pin configurations identical between these parts?

A: Yes. Both devices use the TO-92-3 package with identical pin assignments for through-hole mounting.

Q: Does the DS1818-5+ have the same voltage threshold?

A: Yes. Both parts monitor a 3.06V threshold with active-low reset output and 100ms minimum reset timeout.

Q: What is the difference in RoHS compliance?

A: The DS1816-5 is RoHS non-compliant, while the DS1818-5+ is ROHS3 compliant. This distinction is relevant for applications subject to RoHS regulations.