Request Quote
(Ships tomorrow)
DS1816-5 Equivalent & Substitute Parts
Part Overview
The DS1816-5 is a single-channel power supply supervisor IC from Analog Devices Inc./Maxim Integrated's EconoReset series, designed for power-on reset and simple reset applications. This device monitors a single voltage threshold at 3.06V and provides an active-low reset output via open drain or open collector configuration. The DS1816-5 is classified as obsolete, making identification of compatible substitute parts essential for ongoing system support and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | DS1816-5 |
| Manufacturer | Analog Devices Inc./Maxim Integrated |
| Category | Power Management (PMIC) |
| Package / Case | TO-226-3, TO-92-3 (TO-226AA) |
| Mounting Type | Through Hole |
| Number of Voltages Monitored | 1 |
| Voltage - Threshold | 3.06V |
| Output Type | Open Drain or Open Collector |
| Reset Logic | Active Low |
| Reset Timeout | 100ms Minimum |
| Operating Temperature Range | -40°C ~ 85°C (TA) |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution of the DS1816-5 is determined by strict equivalence across the following critical parameters:
- Single voltage monitoring channel with 3.06V threshold
- Open drain or open collector output configuration
- Active-low reset logic with 100ms minimum timeout
- Through-hole mounting in TO-92-3 package
- Operating temperature range of -40°C to 85°C
- EconoReset series compatibility
The DS1818-5+ meets all these criteria and serves as a parametric equivalent. The primary distinction is product status: the DS1816-5 is obsolete while the DS1818-5+ is active, along with improved RoHS compliance status.
Parameter Comparison
| Parameter | DS1816-5 | DS1818-5+ |
|---|---|---|
| Manufacturer | Analog Devices Inc./Maxim Integrated | Analog Devices Inc./Maxim Integrated |
| Series | EconoReset | EconoReset |
| Number of Voltages Monitored | 1 | 1 |
| Voltage - Threshold | 3.06V | 3.06V |
| Output Type | Open Drain or Open Collector | Open Drain or Open Collector |
| Reset Logic | Active Low | Active Low |
| Reset Timeout | 100ms Minimum | 100ms Minimum |
| Operating Temperature Range | -40°C ~ 85°C (TA) | -40°C ~ 85°C (TA) |
| Package / Case | TO-226-3, TO-92-3 (TO-226AA) | TO-226-3, TO-92-3 (TO-226AA) |
| Mounting Type | Through Hole | Through Hole |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8542.39.0001 | 8542.39.0001 |
Engineering Selection Recommendations
The DS1818-5+ is the direct substitute for the obsolete DS1816-5. Both devices are electrically and mechanically identical across all functional parameters. Selection of the DS1818-5+ is supported by its active product status and ROHS3 compliance, which provides regulatory advantage for new designs and ongoing production. The DS1818-5+ maintains full compatibility with existing circuit designs using the DS1816-5, requiring no modifications to PCB layouts or signal routing due to identical TO-92-3 packaging and pin configuration.
Frequently Asked Questions (FAQ)
Q: Can the DS1818-5+ be used as a direct replacement for the DS1816-5 in existing designs?
A: Yes. The DS1818-5+ is a parametric equivalent with identical electrical specifications, threshold voltage, output configuration, and package type. No circuit modifications are required.
Q: What is the primary reason to transition from DS1816-5 to DS1818-5+?
A: The DS1816-5 is obsolete. The DS1818-5+ is an active product from the same manufacturer and series, ensuring continued availability and supply chain reliability. Additionally, the DS1818-5+ meets ROHS3 compliance requirements.
Q: Are the pin configurations identical between these parts?
A: Yes. Both devices use the TO-92-3 package with identical pin assignments for through-hole mounting.
Q: Does the DS1818-5+ have the same voltage threshold?
A: Yes. Both parts monitor a 3.06V threshold with active-low reset output and 100ms minimum reset timeout.
Q: What is the difference in RoHS compliance?
A: The DS1816-5 is RoHS non-compliant, while the DS1818-5+ is ROHS3 compliant. This distinction is relevant for applications subject to RoHS regulations.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts