DS1110S-250 Equivalent & Substitute Parts

Part Overview

The DS1110S-250 is a nonprogrammable delay line IC manufactured by Analog Devices Inc./Maxim Integrated, designed for clock and timing applications. This 10-tap delay line device provides a fixed 250ns total delay with 25ns tap increments in a 16-SOIC surface mount package. The main part number DS1110S-250 is classified as obsolete, making identification of compatible substitute parts essential for ongoing system support and new design implementations.

Substiute Parts

DS1110S-250
Analog Devices Inc./Maxim IntegratedIn Stock: 872DS1110S-250 Datasheet
DS1110S-250
Current Part
DS1110S-250+
Analog Devices Inc./Maxim IntegratedIn Stock: 971DS1110S-250+ Datasheet
DS1110S-250+
Direct

Key Parameters

Parameter Value
Manufacturer Part Number DS1110S-250
Manufacturer Analog Devices Inc./Maxim Integrated
Category Clock/Timing
Number of Taps/Steps 10
Function Nonprogrammable
Delay to 1st Tap 25ns
Tap Increment 25ns
Available Total Delays 250ns
Number of Independent Delays 1
Voltage - Supply 4.75V ~ 5.25V
Operating Temperature -40°C ~ 85°C
Package / Case 16-SOIC (0.295", 7.50mm Width)
Mounting Type Surface Mount
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the DS1110S-250 is determined by strict equivalence across the following critical parameters:

  • Number of Taps/Steps: 10
  • Function: Nonprogrammable
  • Delay to 1st Tap: 25ns
  • Tap Increment: 25ns
  • Available Total Delays: 250ns
  • Number of Independent Delays: 1
  • Voltage - Supply: 4.75V ~ 5.25V
  • Operating Temperature: -40°C ~ 85°C
  • Package / Case: 16-SOIC (0.295", 7.50mm Width)
  • Mounting Type: Surface Mount

The DS1110S-250+ qualifies as a direct substitute based on identical electrical specifications and package configuration. The primary distinction between these parts is product status and compliance certification.

Parameter Comparison

Parameter DS1110S-250 (Main) DS1110S-250+ (Substitute)
Manufacturer Part Number DS1110S-250 DS1110S-250+
Manufacturer Analog Devices Inc./Maxim Integrated Analog Devices Inc./Maxim Integrated
Category Clock/Timing Clock/Timing
Number of Taps/Steps 10 10
Function Nonprogrammable Nonprogrammable
Delay to 1st Tap 25ns 25ns
Tap Increment 25ns 25ns
Available Total Delays 250ns 250ns
Number of Independent Delays 1 1
Voltage - Supply 4.75V ~ 5.25V 4.75V ~ 5.25V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Package / Case 16-SOIC (0.295", 7.50mm Width) 16-SOIC (0.295", 7.50mm Width)
Mounting Type Surface Mount Surface Mount
Product Status Obsolete Active
RoHS Status RoHS non-compliant ROHS3 Compliant
Packaging Not specified Tube

Engineering Selection Recommendations

The DS1110S-250+ is the direct functional equivalent to the DS1110S-250. Both parts share identical electrical and mechanical specifications, ensuring pin-for-pin and functional compatibility in circuit applications.

The DS1110S-250+ offers two significant advantages over the obsolete DS1110S-250:

  • Active product status ensures continued availability and manufacturer support
  • ROHS3 compliance meets current environmental and regulatory requirements, whereas the DS1110S-250 is RoHS non-compliant

For new designs and ongoing system support, the DS1110S-250+ is the appropriate selection. For legacy systems currently using the DS1110S-250, direct substitution with the DS1110S-250+ is electrically and mechanically valid without circuit modification.

Frequently Asked Questions (FAQ)

Q: Are DS1110S-250 and DS1110S-250+ pin-for-pin compatible?

A: Yes. Both parts use the 16-SOIC package with identical pinout and electrical characteristics. Direct substitution on the PCB is possible without layout changes.

Q: What is the functional difference between these parts?

A: There is no functional difference. Both are nonprogrammable 10-tap delay line ICs with 250ns total delay and 25ns tap increments. Electrical performance is identical.

Q: Why is the DS1110S-250 listed as obsolete?

A: The DS1110S-250 has been discontinued by the manufacturer. The DS1110S-250+ is the active replacement part.

Q: Does RoHS compliance affect circuit performance?

A: No. RoHS compliance relates to material composition and environmental standards, not electrical or timing performance. Both parts operate identically in circuit.

Q: Can I use DS1110S-250+ in a design originally specified for DS1110S-250?

A: Yes. The DS1110S-250+ is a direct substitute with identical electrical specifications, package, and pinout. No design changes are required.

Q: What packaging is available for the DS1110S-250+?

A: The DS1110S-250+ is supplied in tube packaging. The original DS1110S-250 packaging specification was not provided.

Request Quote (Ships tomorrow)