Equivalent & Substitute Parts Reference: DPBW03F-12

Part Overview

DPBW03F-12 from MEAN WELL USA Inc. is an active, isolated module DC-DC converter, delivering dual outputs of +12V and -12V at a maximum 125mA each, with a total power rating of 3W and wide input range (9V to 36V). The device targets commercial ITE applications, featuring remote on/off, over-current protection (OCP), short-circuit protection (SCP), and under-voltage lockout (UVLO). The need for substitute or equivalent models arises from system design flexibility, multi-sourcing strategies, and supply chain assurance. Equivalents must strictly match both the electrical and mechanical parameters specified.

Substiute Parts

DPBW03F-12
MEAN WELL USA Inc.In Stock: 2159DPBW03F-12 Datasheet
DPBW03F-12
Current Part
IP2412S
XP PowerIn Stock: 912IP2412S Datasheet
IP2412S
Similar

Key Parameters

ParameterDPBW03F-12
Manufacturer Part NumberDPBW03F-12
DescriptionDC DC CONVERTER +/-12V 3W
Output Voltage(s)12V, -12V
Max Output Current125mA, 125mA
Power (Watts)3 W
Input Voltage Range9V - 36V
Voltage - Isolation1.5 kV
Number of Outputs2
Operating Temperature Range-40°C ~ 85°C (With Derating)
Efficiency83%
Mounting TypeThrough Hole
Package / Case8-SIP Module, 7 Leads
Size / Dimensions0.86" x 0.36" x 0.44" (21.8mm x 9.2mm x 11.1mm)
RoHS StatusROHS3 Compliant
MSL1 (Unlimited)
Product StatusActive
ApplicationsITE (Commercial)

Substitute Part Grouping Explanation

Substitute relationships for DC-DC converters are defined strictly by key electrical and mechanical parameters: output voltages, output current ratings, input voltage range, isolation voltage specification, power rating, number of outputs, operating temperature limits, mounting type, and package dimensions. Compliance statuses (RoHS, MSL) and product activity are strictly maintained. All listed substitute models must match these values to qualify as functional alternatives for DPBW03F-12.

Parameter Comparison

Parameter DPBW03F-12 (MEAN WELL USA Inc.) IP2412S (XP Power)
DescriptionDC DC CONVERTER +/-12V 3WDC DC CONVERTER +/-12V 3W
Number of Outputs22
Input Voltage Range9V - 36V9V - 36V
Output Voltage 112V12V
Output Voltage 2-12V-12V
Max Output Current125mA, 125mA125mA, 125mA
Power (Watts)3 W3 W
Voltage - Isolation1.5 kV1.6 kV
Operating Temperature Range-40°C ~ 85°C (With Derating)-40°C ~ 85°C
Efficiency83%79%
Mounting TypeThrough HoleThrough Hole
Package / Case8-SIP Module, 7 Leads8-SIP Module, 7 Leads
Size / Dimensions0.86" x 0.36" x 0.44" (21.8mm x 9.2mm x 11.1mm)0.86" x 0.36" x 0.44" (21.9mm x 9.2mm x 11.1mm)
RoHS StatusROHS3 CompliantROHS3 Compliant
MSL1 (Unlimited)1 (Unlimited)
Product StatusActiveActive
ApplicationsITE (Commercial)ITE (Commercial)

Engineering Selection Recommendations

Both DPBW03F-12 and IP2412S are active, ROHS3 compliant, and rated MSL1 (Unlimited), permitting interchangeable use in commercial ITE applications where these compliance requirements are essential. They share matching electrical and mechanical specifications, with minor variation in isolation voltage and efficiency. Component selection should be determined strictly by required certification and active inventory consideration.

Frequently Asked Questions (FAQ)

Q1: What are the mandatory parameters for substituting DPBW03F-12 in a design?
A1: Substitute parts must exactly match the input voltage range, output voltages, maximum output currents, power rating, isolation voltage, mounting type, package type, operating temperature range, RoHS status, MSL rating, and product status.

Q2: Does the package format of IP2412S match DPBW03F-12 for drop-in compatibility?
A2: Yes. Both use an 8-SIP Module with 7 leads, with nearly identical dimensions.

Q3: Are there differences in certifications between DPBW03F-12 and IP2412S?
A3: Both are ROHS3 compliant and MSL 1 (Unlimited). No differences in compliance are listed in the provided parameters.

Q4: How does isolation voltage affect substitution?
A4: Substitution is allowed as the isolation voltages are within the same magnitude (1.5 kV vs. 1.6 kV), matching category requirements.

Q5: Is efficiency a strict substitution criterion?
A5: Efficiency values are stated; selection must maintain the specified minimum value where critical for system needs.

Q6: What application categories are supported for substitution?
A6: Both main and substitute parts are specified for ITE (Commercial) use, thus are applicable as equivalents within this category.

Request Quote (Ships tomorrow)