DP4-52Z Equivalent & Substitute Parts Reference

Part Overview

The DP4-52Z is a vented gauge pressure sensor manufactured by Panasonic Industrial Automation Sales, designed for industrial automation applications. This sensor operates at 1000 kPa (145.04 PSI) with NPN open collector output and is compatible with 12V to 24V supply voltage. The DP4-52Z is classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance and component procurement.

Substiute Parts

DP4-52Z
Panasonic Industrial Automation SalesIn Stock: 1114DP4-52Z Datasheet
DP4-52Z
Current Part
DP-002
Panasonic Industrial Automation SalesIn Stock: 924DP-002 Datasheet
DP-002
Similar

Key Parameters

Parameter Value
Manufacturer Part Number DP4-52Z
Manufacturer Panasonic Industrial Automation Sales
Series DP4
Product Status Obsolete
Pressure Type Vented Gauge
Operating Pressure 1000 kPa (145.04 PSI)
Maximum Pressure 1470 kPa (213.21 PSI)
Output Type NPN - Open Collector
Voltage Supply 12V ~ 24V
Port Size Female - M5
Port Style Threaded
Operating Temperature 0°C ~ 50°C
Termination Style Connector
Package / Case Module Box with Display
RoHS Status RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the DP4-52Z is determined by strict alignment of the following critical parameters:

  • Pressure Type: Vented Gauge (must match)
  • Operating Pressure: 1000 kPa nominal (must match)
  • Output Type: NPN - Open Collector (must match)
  • Voltage Supply Range: 12V ~ 24V (must match)
  • Port Size and Style: Female - M5 Threaded (must match)
  • Operating Temperature Range: 0°C ~ 50°C (must match)
  • Package Type: Module Box with Display (must match)

The DP-002 is identified as a functionally equivalent substitute based on matching all critical electrical and mechanical parameters. Both sensors operate at identical pressure ratings, supply voltage ranges, and output configurations. The primary distinction is product status and termination style, which does not affect functional compatibility in applications designed for the DP4-52Z.

Parameter Comparison

Parameter DP4-52Z (Main Part) DP-002 (Substitute)
Manufacturer Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales
Pressure Type Vented Gauge Vented Gauge
Operating Pressure 1000 kPa (145.04 PSI) 1000 kPa (145.04 PSI)
Maximum Pressure 1470 kPa (213.21 PSI) 1500 kPa (217.56 PSI)
Output Type NPN - Open Collector NPN - Open Collector
Voltage Supply 12V ~ 24V 12V ~ 24V
Port Size Female - M5 Female - M5
Port Style Threaded Threaded
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C
Termination Style Connector Cable/Wire Leads
Package / Case Module Box with Display Module Box with Display
Product Status Obsolete Active
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The DP-002 is the designated equivalent substitute for the obsolete DP4-52Z. Both components meet identical functional requirements for vented gauge pressure sensing in the 1000 kPa operating range with NPN open collector output.

The DP-002 offers the advantage of active product status, ensuring continued availability and supply chain reliability. Both parts maintain equivalent RoHS compliance certifications (RoHS Compliant and ROHS3 Compliant respectively), satisfying regulatory requirements for industrial automation applications.

The primary consideration during substitution is the termination style difference: the DP4-52Z uses a connector interface, while the DP-002 employs cable/wire leads. System integration must account for this interface change during component replacement.

Frequently Asked Questions (FAQ)

Q: Can the DP-002 directly replace the DP4-52Z in existing installations?

A: The DP-002 provides functional equivalence for all electrical and mechanical parameters. However, the termination style differs (connector versus cable/wire leads), requiring appropriate interface adaptation during installation.

Q: Are there compliance differences between the DP4-52Z and DP-002?

A: Both components are RoHS compliant. The DP4-52Z carries RoHS Compliant certification, while the DP-002 carries ROHS3 Compliant certification. Both meet industrial automation regulatory requirements.

Q: What is the significance of the product status difference?

A: The DP4-52Z is classified as obsolete, indicating discontinued manufacturing. The DP-002 maintains active product status, ensuring ongoing availability, technical support, and supply chain continuity.

Q: Do the pressure ratings differ between these sensors?

A: Both sensors operate at 1000 kPa nominal pressure. The maximum pressure rating for the DP4-52Z is 1470 kPa, while the DP-002 is rated to 1500 kPa. This difference does not affect compatibility in applications designed for the DP4-52Z.

Q: Are the operating temperature ranges identical?

A: Yes, both sensors operate across the 0°C to 50°C temperature range, ensuring thermal compatibility in equivalent applications.

Q: What packaging considerations apply to substitution?

A: Both components are supplied in Module Box with Display packaging. The termination interface change (connector to cable/wire leads) is the primary packaging-related consideration for system integration.