Request Quote
(Ships tomorrow)
DP4-52Z Equivalent & Substitute Parts Reference
Part Overview
The DP4-52Z is a vented gauge pressure sensor manufactured by Panasonic Industrial Automation Sales, designed for industrial automation applications. This sensor operates at 1000 kPa (145.04 PSI) with NPN open collector output and is compatible with 12V to 24V supply voltage. The DP4-52Z is classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance and component procurement.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | DP4-52Z |
| Manufacturer | Panasonic Industrial Automation Sales |
| Series | DP4 |
| Product Status | Obsolete |
| Pressure Type | Vented Gauge |
| Operating Pressure | 1000 kPa (145.04 PSI) |
| Maximum Pressure | 1470 kPa (213.21 PSI) |
| Output Type | NPN - Open Collector |
| Voltage Supply | 12V ~ 24V |
| Port Size | Female - M5 |
| Port Style | Threaded |
| Operating Temperature | 0°C ~ 50°C |
| Termination Style | Connector |
| Package / Case | Module Box with Display |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the DP4-52Z is determined by strict alignment of the following critical parameters:
- Pressure Type: Vented Gauge (must match)
- Operating Pressure: 1000 kPa nominal (must match)
- Output Type: NPN - Open Collector (must match)
- Voltage Supply Range: 12V ~ 24V (must match)
- Port Size and Style: Female - M5 Threaded (must match)
- Operating Temperature Range: 0°C ~ 50°C (must match)
- Package Type: Module Box with Display (must match)
The DP-002 is identified as a functionally equivalent substitute based on matching all critical electrical and mechanical parameters. Both sensors operate at identical pressure ratings, supply voltage ranges, and output configurations. The primary distinction is product status and termination style, which does not affect functional compatibility in applications designed for the DP4-52Z.
Parameter Comparison
| Parameter | DP4-52Z (Main Part) | DP-002 (Substitute) |
|---|---|---|
| Manufacturer | Panasonic Industrial Automation Sales | Panasonic Industrial Automation Sales |
| Pressure Type | Vented Gauge | Vented Gauge |
| Operating Pressure | 1000 kPa (145.04 PSI) | 1000 kPa (145.04 PSI) |
| Maximum Pressure | 1470 kPa (213.21 PSI) | 1500 kPa (217.56 PSI) |
| Output Type | NPN - Open Collector | NPN - Open Collector |
| Voltage Supply | 12V ~ 24V | 12V ~ 24V |
| Port Size | Female - M5 | Female - M5 |
| Port Style | Threaded | Threaded |
| Operating Temperature | 0°C ~ 50°C | 0°C ~ 50°C |
| Termination Style | Connector | Cable/Wire Leads |
| Package / Case | Module Box with Display | Module Box with Display |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The DP-002 is the designated equivalent substitute for the obsolete DP4-52Z. Both components meet identical functional requirements for vented gauge pressure sensing in the 1000 kPa operating range with NPN open collector output.
The DP-002 offers the advantage of active product status, ensuring continued availability and supply chain reliability. Both parts maintain equivalent RoHS compliance certifications (RoHS Compliant and ROHS3 Compliant respectively), satisfying regulatory requirements for industrial automation applications.
The primary consideration during substitution is the termination style difference: the DP4-52Z uses a connector interface, while the DP-002 employs cable/wire leads. System integration must account for this interface change during component replacement.
Frequently Asked Questions (FAQ)
Q: Can the DP-002 directly replace the DP4-52Z in existing installations?
A: The DP-002 provides functional equivalence for all electrical and mechanical parameters. However, the termination style differs (connector versus cable/wire leads), requiring appropriate interface adaptation during installation.
Q: Are there compliance differences between the DP4-52Z and DP-002?
A: Both components are RoHS compliant. The DP4-52Z carries RoHS Compliant certification, while the DP-002 carries ROHS3 Compliant certification. Both meet industrial automation regulatory requirements.
Q: What is the significance of the product status difference?
A: The DP4-52Z is classified as obsolete, indicating discontinued manufacturing. The DP-002 maintains active product status, ensuring ongoing availability, technical support, and supply chain continuity.
Q: Do the pressure ratings differ between these sensors?
A: Both sensors operate at 1000 kPa nominal pressure. The maximum pressure rating for the DP4-52Z is 1470 kPa, while the DP-002 is rated to 1500 kPa. This difference does not affect compatibility in applications designed for the DP4-52Z.
Q: Are the operating temperature ranges identical?
A: Yes, both sensors operate across the 0°C to 50°C temperature range, ensuring thermal compatibility in equivalent applications.
Q: What packaging considerations apply to substitution?
A: Both components are supplied in Module Box with Display packaging. The termination interface change (connector to cable/wire leads) is the primary packaging-related consideration for system integration.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts