DP4-52P Pressure Sensor Equivalent & Substitute Parts

Part Overview

The DP4-52P is a vented gauge pressure sensor manufactured by Panasonic Industrial Automation Sales, designed for industrial automation applications. This sensor operates at 1 MPA (1000 kPa / 145.04 PSI) with PNP open collector output and dual voltage supply compatibility (12V ~ 24V). The DP4-52P is classified as obsolete, making identification of functionally equivalent substitute parts essential for system maintenance, repair, and component sourcing.

Substiute Parts

DP4-52P
Panasonic Industrial Automation SalesIn Stock: 1103DP4-52P Datasheet
DP4-52P
Current Part
DP-002-P
Panasonic Industrial Automation SalesIn Stock: 880DP-002-P Datasheet
DP-002-P
Similar
DP-102-N-P
Panasonic Industrial Automation SalesIn Stock: 688DP-102-N-P Datasheet
DP-102-N-P
Similar

Key Parameters

Parameter DP4-52P
Manufacturer Panasonic Industrial Automation Sales
Series DP4
Product Status Obsolete
Pressure Type Vented Gauge
Operating Pressure 145.04 PSI (1000 kPa)
Maximum Pressure 213.21 PSI (1470 kPa)
Output Type PNP - Open Collector
Voltage Supply 12V ~ 24V
Port Size Female - M5
Port Style Threaded
Termination Style Connector
Operating Temperature 0°C ~ 50°C
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitute parts for the DP4-52P are qualified based on the following critical parameters that determine functional compatibility:

Core Compatibility Criteria:

  • Pressure Type: Vented Gauge (all substitutes maintain this classification)
  • Output Type: PNP - Open Collector (electrical interface requirement)
  • Voltage Supply: 12V ~ 24V (power supply compatibility)
  • Port Style: Threaded (mechanical interface requirement)
  • Operating Pressure Range: Must accommodate or exceed 1000 kPa nominal operating point
  • Maximum Pressure Rating: Must support the system's maximum pressure envelope

Qualified Substitutes:

DP-002-P qualifies as a substitute based on identical operating pressure (1000 kPa), matching output type (PNP - Open Collector), compatible voltage supply (12V ~ 24V), identical port size and style (Female - M5 Threaded), and higher maximum pressure rating (1500 kPa). The primary difference is termination style (Cable/Wire Leads vs. Connector) and active product status.

DP-102-N-P qualifies as a substitute based on compatible output type (PNP - Open Collector), matching voltage supply (12V ~ 24V), compatible port styles (Female - M5 and Male 1/8" NPT Threaded), operating pressure range that encompasses the DP4-52P nominal point (−100 kPa ~ 1000 kPa), and higher maximum pressure capability (−150 kPa ~ 1500 kPa). This part offers extended temperature range (−10°C ~ 50°C) and active product status.

Parameter Comparison

Parameter DP4-52P DP-002-P DP-102-N-P
Manufacturer Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales
Pressure Type Vented Gauge Vented Gauge Vented Gauge
Operating Pressure 145.04 PSI (1000 kPa) 145.04 PSI (1000 kPa) −14.5 PSI ~ 145.04 PSI (−100 kPa ~ 1000 kPa)
Maximum Pressure 213.21 PSI (1470 kPa) 217.56 PSI (1500 kPa) −21.76 PSI ~ 217.56 PSI (−150 kPa ~ 1500 kPa)
Output Type PNP - Open Collector PNP - Open Collector PNP - Open Collector
Voltage Supply 12V ~ 24V 12V ~ 24V 12V ~ 24V
Port Size Female - M5 Female - M5 Female - M5, Male - 1/8" (3.18mm) NPT
Port Style Threaded Threaded Threaded
Termination Style Connector Cable/Wire Leads Connector
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C −10°C ~ 50°C
Product Status Obsolete Active Active
RoHS Status RoHS Compliant ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

DP-002-P is recommended for direct replacement applications where connector-based termination is not required. This part maintains identical operating pressure specifications (1000 kPa) and temperature range (0°C ~ 50°C) as the DP4-52P, with the advantage of active product status and ROHS3 compliance. The cable/wire lead termination requires integration with existing connector infrastructure or field modification.

DP-102-N-P is recommended for applications requiring extended operational flexibility. This part supports both positive and negative gauge pressure operation (−100 kPa ~ 1000 kPa), provides connector-based termination matching the DP4-52P interface, and offers extended low-temperature capability (−10°C operation vs. 0°C minimum). Active product status and ROHS3 compliance ensure long-term availability and regulatory alignment.

Both substitutes maintain PNP open collector output compatibility, dual voltage supply operation (12V ~ 24V), and threaded port interfaces. Selection between DP-002-P and DP-102-N-P depends on termination style requirements and operating temperature envelope specifications for the target application.

Frequently Asked Questions (FAQ)

Q: Can DP-002-P and DP-102-N-P be used interchangeably with DP4-52P?

A: Both parts are functionally compatible based on core electrical and mechanical parameters (PNP output, 12V ~ 24V supply, threaded M5 port, vented gauge pressure type). However, termination style differs: DP4-52P and DP-102-N-P use connectors, while DP-002-P uses cable/wire leads. Port configuration also differs; DP-102-N-P offers dual port options (M5 and 1/8" NPT).

Q: What is the significance of the operating pressure range difference between DP4-52P and DP-102-N-P?

A: DP4-52P operates at positive gauge pressure only (1000 kPa nominal). DP-102-N-P supports both positive and negative gauge pressure (−100 kPa ~ 1000 kPa), enabling vacuum or below-atmospheric applications. For systems requiring positive pressure only, both parts are equivalent at the 1000 kPa operating point.

Q: Why is DP4-52P classified as obsolete?

A: Obsolete status indicates the part is no longer manufactured or supported by Panasonic Industrial Automation Sales. DP-002-P and DP-102-N-P are active products with ongoing availability and support.

Q: Are there termination compatibility considerations when substituting DP4-52P?

A: Yes. DP4-52P uses connector termination. DP-002-P uses cable/wire leads, requiring integration with existing connector systems or field termination. DP-102-N-P maintains connector termination, simplifying direct replacement in connector-based installations.

Q: Do all three parts meet current regulatory compliance standards?

A: DP4-52P is RoHS Compliant. DP-002-P and DP-102-N-P are ROHS3 Compliant, representing current regulatory alignment. All three parts carry EAR99 ECCN classification and 9026.20.4000 HTSUS code.

Request Quote (Ships tomorrow)