DP4-50P Vacuum Pressure Sensor - Equivalent & Substitute Parts

Part Overview

The DP4-50P is a vacuum pressure sensor manufactured by Panasonic Industrial Automation Sales, designed for industrial automation applications requiring vacuum pressure measurement in the 0 to -101.3 kPa range. This sensor features PNP open collector output and operates across 12V to 24V supply voltage with a threaded female M5 port connection.

The DP4-50P is classified as obsolete. Identifying equivalent substitute parts is necessary to maintain system functionality and ensure continued availability for replacement, repair, and new installations where this sensor specification is required.

Substiute Parts

DP4-50P
Panasonic Industrial Automation SalesIn Stock: 1227DP4-50P Datasheet
DP4-50P
Current Part
E8F2-AN0B
Omron Automation and SafetyIn Stock: 1153E8F2-AN0B Datasheet
E8F2-AN0B
Similar

Key Parameters

Parameter DP4-50P Value
Manufacturer Panasonic Industrial Automation Sales
Series DP4
Product Status Obsolete
Pressure Type Vacuum
Operating Pressure Range -14.65 PSI (-101 kPa)
Output Type PNP - Open Collector
Voltage Supply 12V ~ 24V
Port Size Female - M5
Port Style Threaded
Operating Temperature 0°C ~ 50°C
Maximum Pressure -71.07 PSI (-490 kPa)
RoHS Status RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

The E8F2-AN0B from Omron Automation and Safety qualifies as a substitute for the DP4-50P based on the following critical parameters:

Matching Parameters (Substitution Basis):

  • Pressure Type: Both measure vacuum pressure
  • Operating Pressure Range: Both operate at -14.65 PSI (-101 kPa)
  • Output Type: Both feature PNP - Open Collector output
  • Voltage Supply: Both operate on 12V ~ 24V
  • Port Style: Both use threaded connections
  • RoHS Compliance: Both are RoHS Compliant
  • Moisture Sensitivity Level: Both rated at MSL 1 (Unlimited)

Differences to Consider:

  • Port Size: DP4-50P uses Female M5; E8F2-AN0B offers Female M5 and Male 1/8" BSPT options
  • Output Signal: DP4-50P provides no specified output voltage; E8F2-AN0B provides 1V ~ 5V output
  • Accuracy: DP4-50P accuracy not specified; E8F2-AN0B provides ±3% accuracy
  • Maximum Pressure: DP4-50P rated to -71.07 PSI; E8F2-AN0B rated to -58.02 PSI
  • Operating Temperature: DP4-50P operates 0°C ~ 50°C; E8F2-AN0B operates 0°C ~ 55°C
  • Termination Style: DP4-50P uses Connector; E8F2-AN0B uses Cable

Parameter Comparison

Parameter DP4-50P E8F2-AN0B
Manufacturer Panasonic Industrial Automation Sales Omron Automation and Safety
Product Status Obsolete Active
Pressure Type Vacuum Vacuum
Operating Pressure -14.65 PSI (-101 kPa) -14.65 PSI (-101 kPa)
Output Type PNP - Open Collector PNP - Open Collector
Output Signal Not specified 1V ~ 5V
Accuracy Not specified ±3%
Voltage Supply 12V ~ 24V 12V ~ 24V
Port Size Female - M5 Female - M5, Male - 1/8" BSPT
Port Style Threaded Threaded
Maximum Pressure -71.07 PSI (-490 kPa) -58.02 PSI (-400 kPa)
Operating Temperature 0°C ~ 50°C 0°C ~ 55°C
Termination Style Connector Cable
RoHS Status RoHS Compliant RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The E8F2-AN0B is an active product from Omron Automation and Safety and serves as a functional substitute for the obsolete DP4-50P. Both sensors meet identical vacuum pressure measurement requirements, operate within the same supply voltage range, and share PNP open collector output architecture.

Selection of the E8F2-AN0B over the DP4-50P is supported by:

  • Active product status ensuring ongoing availability and supply chain reliability
  • RoHS compliance matching the original specification
  • Identical operating pressure range and output type
  • Expanded operating temperature range (0°C ~ 55°C vs. 0°C ~ 50°C)
  • Specified output signal (1V ~ 5V) and accuracy (±3%) providing measurable performance characteristics

Integration considerations include port connection compatibility (M5 female available on E8F2-AN0B) and termination style transition from connector to cable, which may require interface adaptation depending on system design.

Frequently Asked Questions (FAQ)

Q: Can the E8F2-AN0B directly replace the DP4-50P without modifications?

A: The E8F2-AN0B matches the DP4-50P on core functional parameters: vacuum pressure measurement, operating pressure range, PNP output type, and supply voltage. However, the termination style differs (connector vs. cable), requiring interface adaptation. Port size compatibility exists with the M5 female option on the E8F2-AN0B.

Q: What are the critical parameters for substitution between these sensors?

A: Substitution is valid when the following parameters align: pressure type (vacuum), operating pressure range (-101 kPa), output type (PNP - Open Collector), supply voltage (12V ~ 24V), and port style (threaded). These parameters define functional equivalence for industrial automation applications.

Q: Does the E8F2-AN0B have a lower maximum pressure rating than the DP4-50P?

A: Yes. The DP4-50P is rated to -71.07 PSI (-490 kPa) maximum pressure, while the E8F2-AN0B is rated to -58.02 PSI (-400 kPa). Applications requiring operation beyond -400 kPa must account for this difference.

Q: Are both sensors RoHS compliant?

A: Yes. Both the DP4-50P and E8F2-AN0B are RoHS Compliant with MSL 1 (Unlimited) moisture sensitivity level.

Q: What is the difference in operating temperature range?

A: The DP4-50P operates from 0°C to 50°C, while the E8F2-AN0B operates from 0°C to 55°C. The E8F2-AN0B provides a 5°C extended upper temperature range.

Q: Does the E8F2-AN0B provide output signal specifications?

A: Yes. The E8F2-AN0B provides a 1V ~ 5V output signal with ±3% accuracy. The DP4-50P does not specify output voltage or accuracy characteristics.

Request Quote (Ships tomorrow)