Request Quote
(Ships tomorrow)
DP2-41 Equivalent & Substitute Parts Reference
Part Overview
The DP2-41 is a vented gauge pressure sensor manufactured by Panasonic Industrial Automation Sales, designed for industrial automation applications. It provides analog voltage output with NPN open collector capability, operating across a 12V to 24V supply range. The part is currently classified as obsolete, which necessitates identification of functionally equivalent active alternatives from the DP-100 series that maintain compatibility with existing system requirements.
Substiute Parts
Key Parameters
| Parameter | DP2-41 |
|---|---|
| Manufacturer | Panasonic Industrial Automation Sales |
| Series | DP2 |
| Product Status | Obsolete |
| Pressure Type | Vented Gauge |
| Operating Pressure | 14.5 PSI (100 kPa) |
| Output Type | Analog Voltage, NPN - Open Collector |
| Voltage Supply | 12V ~ 24V |
| Port Size | Female - 1/8" (3.18 mm) BSPT |
| Port Style | Threaded |
| Maximum Pressure | 71.07 PSI (490 kPa) |
| Operating Temperature | -10°C ~ 50°C |
| Termination Style | Connector |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the DP2-41 is determined by alignment across the following critical parameters:
Primary Compatibility Criteria:
- Pressure type classification (vented gauge)
- Operating pressure range (100 kPa nominal)
- Supply voltage compatibility (12V ~ 24V)
- Output signal type (NPN open collector capability)
- Operating temperature range (-10°C ~ 50°C)
- Port style (threaded connection)
- Termination method (connector-based)
The DP-100 series (DP-101-M, DP-101A-M, DP-102-M) shares these core functional parameters with the DP2-41. However, port size differs: DP-100 series uses Female M5 threading versus the DP2-41's Female 1/8" BSPT. This mechanical difference requires adapter consideration during integration.
The DP-102-M operates across an extended pressure range (-100 kPa ~ 1000 kPa) and is suitable only when the application environment permits operation beyond the DP2-41's nominal 100 kPa specification.
Parameter Comparison
| Parameter | DP2-41 | DP-101-M | DP-101A-M | DP-102-M |
|---|---|---|---|---|
| Manufacturer | Panasonic Industrial Automation Sales | Panasonic Industrial Automation Sales | Panasonic Industrial Automation Sales | Panasonic Industrial Automation Sales |
| Product Status | Obsolete | Active | Active | Active |
| Series | DP2 | DP-100 | DP-100 | DP-100 |
| Pressure Type | Vented Gauge | Vented Gauge | Vented Gauge | Vented Gauge |
| Operating Pressure | 14.5 PSI (100 kPa) | ±14.5 PSI (±100 kPa) | ±14.5 PSI (±100 kPa) | -14.5 PSI ~ 145.04 PSI (-100 kPa ~ 1000 kPa) |
| Output Type | Analog Voltage, NPN - Open Collector | NPN - Open Collector | Analog Current/Voltage, NPN - Open Collector | NPN - Open Collector |
| Voltage Supply | 12V ~ 24V | 12V ~ 24V | 12V ~ 24V | 12V ~ 24V |
| Port Size | Female - 1/8" (3.18 mm) BSPT | Female - M5 | Female - M5 | Female - M5 |
| Port Style | Threaded | Threaded | Threaded | Threaded |
| Maximum Pressure | 71.07 PSI (490 kPa) | ±72.52 PSI (±500 kPa) | ±72.52 PSI (±500 kPa) | -21.76 PSI ~ 217.56 PSI (-150 kPa ~ 1500 kPa) |
| Operating Temperature | -10°C ~ 50°C | -10°C ~ 50°C | -10°C ~ 50°C | -10°C ~ 50°C |
| Termination Style | Connector | Connector | Connector | Connector |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
DP-101-M: This part is the primary substitute for DP2-41 applications. Both parts share identical operating pressure (100 kPa nominal), supply voltage range (12V ~ 24V), temperature operating window (-10°C ~ 50°C), and NPN open collector output capability. The DP-101-M is currently in active production status with ROHS3 compliance certification. Port size adaptation from 1/8" BSPT to M5 is required during mechanical integration.
DP-101A-M: This variant provides expanded output flexibility through dual analog current/voltage capability while maintaining all other electrical and thermal specifications identical to DP-101-M. Selection of this part is appropriate when the control system requires current-loop signal processing in addition to voltage output. Active production status and ROHS3 compliance are confirmed.
DP-102-M: This part operates across an extended pressure measurement range (-100 kPa ~ 1000 kPa) compared to the DP2-41's 100 kPa nominal specification. Selection is limited to applications where the system environment or future expansion requirements justify operation beyond the original DP2-41 pressure envelope. Active production status and ROHS3 compliance are confirmed.
Frequently Asked Questions (FAQ)
Q: Can DP-101-M directly replace DP2-41 without mechanical modification?
A: Electrical and functional compatibility is confirmed. However, port size differs: DP2-41 uses Female 1/8" BSPT threading while DP-101-M uses Female M5 threading. A threaded adapter or port modification is required for mechanical integration.
Q: What is the difference between DP-101-M and DP-101A-M?
A: Both parts operate at identical pressure ranges (±100 kPa) and supply voltages (12V ~ 24V). The DP-101A-M provides dual analog current/voltage output capability, whereas DP-101-M provides NPN open collector output only. Selection depends on whether the control system requires current-loop signal processing.
Q: Is DP-102-M suitable as a substitute for DP2-41?
A: DP-102-M shares all core electrical parameters (supply voltage, temperature range, output type, termination style) with DP2-41. However, DP-102-M operates across a significantly wider pressure range (-100 kPa ~ 1000 kPa). This part is appropriate only when the application environment permits or requires operation beyond the DP2-41's 100 kPa nominal specification.
Q: Are all substitute parts RoHS compliant?
A: Yes. DP2-41 carries RoHS Compliant certification. All substitute parts (DP-101-M, DP-101A-M, DP-102-M) carry ROHS3 Compliant certification, which represents an updated compliance standard.
Q: What is the moisture sensitivity level for these parts?
A: All parts, including DP2-41 and all substitutes, carry Moisture Sensitivity Level 1 (Unlimited), indicating no moisture-related handling restrictions during storage or assembly.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts