Equivalent & Substitute Parts for Panasonic DP2-21F Pressure Sensor
Part Overview
The Panasonic Industrial Automation Sales DP2-21F is a vented gauge pressure sensor with analog output and NPN - open collector configuration. It is designed for industrial automation applications, featuring a 100kPa (14.5PSI) operating pressure and threaded, connector-based termination. The product status is obsolete, necessitating identification and selection of compatible and available substitute models for continued system maintenance or replacement.
Substiute Parts
Key Parameters
| Parameter | DP2-21F Value |
|---|---|
| Manufacturer | Panasonic Industrial Automation Sales |
| Series | DP2 |
| Pressure Type | Vented Gauge |
| Operating Pressure | 14.5PSI (100kPa) |
| Output Type | Analog Voltage, NPN - Open Collector |
| Voltage - Supply | 12V ~ 24V |
| Port Size | Female - 1/8" (3.18mm) NPT |
| Port Style | Threaded |
| Termination Style | Connector |
| Maximum Pressure | 71.07PSI (490kPa) |
| Operating Temperature | -10°C ~ 50°C |
| Package / Case | Module Box with Display |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| ECCN | EAR99 |
| HTSUS | 9026.20.4000 |
Substitute Part Grouping Explanation
Substitute candidates are evaluated strictly on the following key parameters for the pressure sensor category:
- Pressure Type (Vented Gauge)
- Operating Pressure (14.5PSI / 100kPa)
- Output Type (NPN - Open Collector)
- Voltage Supply Range (12V ~ 24V)
- Port Size and Style (Female - 1/8" (3.18mm) NPT, Threaded or compatible)
- Termination Style (Connector)
- Maximum Pressure Rating
- Operating Temperature Range
- RoHS Compliance and MSL
- ECCN and HTSUS categorization
Only substitute parts matching these electrical and mechanical attributes are listed.
Parameter Comparison
| Parameter | Main Part: DP2-21F | Substitute: DP-101-N |
|---|---|---|
| Manufacturer | Panasonic Industrial Automation Sales | Panasonic Industrial Automation Sales |
| Pressure Type | Vented Gauge | Vented Gauge |
| Operating Pressure | 14.5PSI (100kPa) | ±14.5PSI (±100kPa) |
| Output Type | Analog Voltage, NPN - Open Collector | NPN - Open Collector |
| Voltage - Supply | 12V ~ 24V | 12V ~ 24V |
| Port Size | Female - 1/8" (3.18mm) NPT | Female - M5, Male - 1/8" (3.18mm) NPT |
| Port Style | Threaded | Threaded |
| Termination Style | Connector | Connector |
| Maximum Pressure | 71.07PSI (490kPa) | ±72.52PSI (±500kPa) |
| Operating Temperature | -10°C ~ 50°C | -10°C ~ 50°C |
| Package / Case | Module Box with Display | Module |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 9026.20.4000 | 9026.20.4000 |
Engineering Selection Recommendations
The DP2-21F has reached obsolete status. Substitute part DP-101-N carries an active product status and aligns in RoHS compliance and Moisture Sensitivity Level (MSL 1 Unlimited). ECCN and HTSUS codes match, supporting continued regulatory alignment. Only substitute models meeting all provided parameters should be selected.
Frequently Asked Questions (FAQ)
Q: What are the main criteria for substituting the DP2-21F pressure sensor?
A: Substitute parts must match in pressure type (vented gauge), operating pressure, output type, supply voltage range, port compatibility, termination style, maximum pressure rating, operating temperature, RoHS compliance, and regulatory classification.
Q: Are the port sizes of DP2-21F and DP-101-N interchangeable?
A: Both offer 1/8" (3.18mm) NPT threaded compatibility; DP-101-N additionally includes M5 female options, providing direct mechanical match based on the provided interface.
Q: Does the output configuration between DP2-21F and DP-101-N align for system integration?
A: Both feature NPN - open collector outputs; DP2-21F specifies analog voltage as well, strict selection should be based on the open collector requirement.
Q: Are substitute models compliant with current RoHS requirements?
A: DP-101-N is listed as ROHS3 Compliant; DP2-21F is RoHS Compliant as per provided data.
Q: What packaging or mounting considerations exist between DP2-21F and DP-101-N?
A: DP2-21F uses a module box with display, while DP-101-N is described as a module. Only specified packaging information should be used for assessment.
Q: Is the maximum pressure rating sufficient for replacement operations?
A: Both models provide a maximum pressure capability above the operating pressure; substitute selection should ensure this parameter meets system safety margins.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts