DLP9000XFLS Digital Micromirror Device Equivalent & Substitute Parts

Part Overview

The DLP9000XFLS is a Digital Micromirror Device (DMD) manufactured by Texas Instruments, housed in a 355-CLGA package measuring 42.2x42.2mm. This component is designed for applications requiring high-resolution spatial light modulation, including 3D projection and medical imaging systems. The DLP9000XFLS is classified as obsolete product status. Due to its obsolete classification, identifying equivalent substitute parts with active product status and maintained inventory availability is essential for ongoing system support and new design implementations.

Substiute Parts

DLP9000XFLS
Texas InstrumentsIn Stock: 722DLP9000XFLS Datasheet
DLP9000XFLS
Current Part
DLP9000XBFLS
Texas InstrumentsIn Stock: 3447DLP9000XBFLS Datasheet
DLP9000XBFLS
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number DLP9000XFLS
Manufacturer Texas Instruments
Type Digital Micromirror Device (DMD)
Package / Case 355-BCLGA
Supplier Device Package 355-CLGA (42.2x42.2)
Mounting Type Surface Mount
Base Product Number DLP9000
Applications 3D, Medical Imaging
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS Code 8542.39.0001

Substitute Part Grouping Explanation

Substitution eligibility for the DLP9000XFLS is determined by strict alignment of the following critical parameters:

Mandatory Matching Parameters:

  • Manufacturer: Texas Instruments
  • Base Product Number: DLP9000
  • Type: Digital Micromirror Device (DMD)
  • Package / Case: 355-BCLGA
  • Supplier Device Package: 355-CLGA (42.2x42.2)
  • Mounting Type: Surface Mount
  • Applications: 3D, Medical Imaging
  • RoHS Status: ROHS3 Compliant
  • REACH Status: REACH Unaffected
  • ECCN: EAR99
  • HTSUS Code: 8542.39.0001

The DLP9000XBFLS qualifies as a direct substitute based on complete alignment with all mandatory parameters. The primary distinction between the main part and its substitute is product status classification and inventory availability.

Parameter Comparison

Parameter DLP9000XFLS DLP9000XBFLS
Manufacturer Part Number DLP9000XFLS DLP9000XBFLS
Manufacturer Texas Instruments Texas Instruments
Type Digital Micromirror Device (DMD) Digital Micromirror Device (DMD)
Description IC DIG MICROMIRROR DEV 355CLGA IC DIG MICROMIRROR DEV 355CLGA
Package / Case 355-BCLGA 355-BCLGA
Supplier Device Package 355-CLGA (42.2x42.2) 355-CLGA (42.2x42.2)
Mounting Type Surface Mount Surface Mount
Base Product Number DLP9000 DLP9000
Applications 3D, Medical Imaging 3D, Medical Imaging
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS Code 8542.39.0001 8542.39.0001
Product Status Obsolete Active
Inventory Status 691 Pcs New Original In Stock 3400 Pcs New Original In Stock

Engineering Selection Recommendations

The DLP9000XBFLS is the designated manufacturer-recommended substitute for the obsolete DLP9000XFLS. Both components maintain identical electrical and mechanical specifications, including package geometry, mounting configuration, and application suitability for 3D and medical imaging systems.

Selection Criteria:

For new designs and ongoing system support, the DLP9000XBFLS is the appropriate selection due to its active product status and higher inventory availability (3400 units versus 691 units). Both parts satisfy ROHS3 compliance and REACH regulatory requirements, ensuring compatibility with current manufacturing and environmental standards.

The DLP9000XFLS remains available for legacy system maintenance where existing component qualification and documentation reference the obsolete part number. However, transition to the DLP9000XBFLS is supported by Texas Instruments and eliminates long-term supply chain risk associated with obsolete product classifications.

Frequently Asked Questions (FAQ)

Q: Can the DLP9000XBFLS directly replace the DLP9000XFLS in existing designs?

A: Yes. The DLP9000XBFLS is electrically and mechanically identical to the DLP9000XFLS. Both components share the same 355-CLGA package geometry, surface mount configuration, and functional specifications for 3D and medical imaging applications.

Q: What is the primary difference between these two part numbers?

A: The DLP9000XBFLS carries active product status with higher inventory availability, while the DLP9000XFLS is classified as obsolete. Both parts meet identical electrical, mechanical, and regulatory requirements.

Q: Are there any package or pinout differences between DLP9000XFLS and DLP9000XBFLS?

A: No. Both components use the 355-BCLGA package with 355-CLGA (42.2x42.2) supplier device package specifications. Pinout and mechanical dimensions are identical.

Q: Do both parts comply with current environmental and regulatory standards?

A: Yes. Both the DLP9000XFLS and DLP9000XBFLS are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements.

Q: Which part should be specified for new product designs?

A: The DLP9000XBFLS should be specified for new designs due to its active product status and maintained supply chain support from Texas Instruments.

Request Quote (Ships tomorrow)