Request Quote
(Ships tomorrow)
DKLL-0346-0804 Equivalent & Substitute Parts
Part Overview
The DKLL-0346-0804 is a 3-line common mode choke (CMC) designed for through-hole mounting with an 8A current rating and 22mOhm maximum DC resistance. Manufactured by SCHURTER Inc., this component is classified as obsolete. Due to its obsolete status, identifying equivalent substitute parts with matching electrical and mechanical specifications is essential for design continuity and procurement planning.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | DKLL-0346-0804 |
| Manufacturer | SCHURTER Inc. |
| Series | DKLL-3 |
| Product Status | Obsolete |
| Number of Lines | 3 |
| Current Rating (Max) | 8A |
| DC Resistance (DCR) (Max) | 22mOhm |
| Voltage Rating - DC | 760V |
| Voltage Rating - AC | 540V |
| Operating Temperature Range | -25°C to 100°C |
| Mounting Type | Through Hole |
| Size / Dimension | 1.969" L x 1.969" W (50.00mm x 50.00mm) |
| RoHS Status | ROHS3 Compliant |
| Approval Agency | UR |
Substitute Part Grouping Explanation
Substitution of the DKLL-0346-0804 is determined by the following critical parameters:
- Number of Lines: 3 (functional requirement for common mode filtering)
- Current Rating (Max): 8A (load capacity specification)
- DC Resistance (DCR) (Max): 22mOhm (electrical performance specification)
- Voltage Rating - DC: 760V (insulation and safety requirement)
- Voltage Rating - AC: 540V (insulation and safety requirement)
- Operating Temperature Range: -25°C to 100°C (environmental compatibility)
- Mounting Type: Through Hole (PCB assembly compatibility)
- RoHS Status: ROHS3 Compliant (regulatory compliance)
- Approval Agency: UR (safety certification)
The DKLL-0346-0804 has one identified parametric equivalent that meets all critical electrical and mechanical specifications.
Parameter Comparison
| Parameter | DKLL-0346-0804 (Main) | DKLP-0329-0804 (Substitute) | Match Status |
|---|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. | Match |
| Number of Lines | 3 | 3 | Match |
| Current Rating (Max) | 8A | 8A | Match |
| DC Resistance (DCR) (Max) | 22mOhm | 22mOhm | Match |
| Voltage Rating - DC | 760V | 760V | Match |
| Voltage Rating - AC | 540V | 540V | Match |
| Operating Temperature Range | -25°C to 100°C | -25°C to 100°C | Match |
| Mounting Type | Through Hole | Through Hole | Match |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Match |
| Approval Agency | UR | UR | Match |
| Product Status | Obsolete | Active | Substitute is Active |
| Size / Dimension | 1.969" L x 1.969" W (50.00mm x 50.00mm) | 1.890" L x 1.890" W (48.00mm x 48.00mm) | Dimensional Variation |
Engineering Selection Recommendations
The DKLP-0329-0804 is the identified parametric equivalent for the obsolete DKLL-0346-0804. Both components are manufactured by SCHURTER Inc. and share identical electrical specifications across all critical parameters: 3-line configuration, 8A current rating, 22mOhm DCR, 760V DC / 540V AC voltage ratings, and -25°C to 100°C operating temperature range.
The DKLP-0329-0804 holds active product status, ensuring ongoing availability and supply chain continuity. Both parts maintain ROHS3 compliance and UR approval certification, satisfying regulatory and safety requirements.
The dimensional difference (50.00mm vs. 48.00mm) represents a minor footprint reduction in the substitute part. PCB layout verification is necessary to confirm that the smaller footprint accommodates existing through-hole mounting patterns and clearance requirements in the target application.
Frequently Asked Questions (FAQ)
Q: Can the DKLP-0329-0804 directly replace the DKLL-0346-0804 in existing designs?
A: The DKLP-0329-0804 matches all electrical specifications of the DKLL-0346-0804. However, the substitute part has a smaller physical footprint (48.00mm vs. 50.00mm). PCB layout compatibility must be verified before implementation to ensure the reduced dimensions do not conflict with existing mounting hole patterns or component spacing.
Q: What makes the DKLP-0329-0804 a suitable substitute?
A: The substitute part meets all critical electrical parameters: identical 3-line configuration, 8A current rating, 22mOhm DCR, voltage ratings (760V DC / 540V AC), and operating temperature range (-25°C to 100°C). Both components share the same manufacturer, mounting type (through-hole), and regulatory certifications (ROHS3, UR approval).
Q: Why is the DKLL-0346-0804 obsolete?
A: The DKLL-0346-0804 is classified as obsolete. The DKLP-0329-0804 is the active equivalent from SCHURTER Inc., ensuring continued product support and supply availability.
Q: Are there any compliance differences between the two parts?
A: No. Both the DKLL-0346-0804 and DKLP-0329-0804 are ROHS3 compliant, REACH unaffected, and hold UR approval certification. Compliance status is identical.
Q: What is the primary consideration when switching from DKLL-0346-0804 to DKLP-0329-0804?
A: The primary consideration is the dimensional footprint reduction from 50.00mm to 48.00mm. Verify that PCB through-hole spacing and component clearances accommodate the smaller package dimensions.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts