DHR 200 C10 Current Sensor - Equivalent & Substitute Parts

Part Overview

The DHR 200 C10 is an active Hall Effect current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications requiring 200A sensing capability. This open-loop, bidirectional module delivers ratiometric output (0 V ~ 10 V) and operates across industrial temperature ranges. The product maintains Active status with full RoHS compliance and REACH unaffected certification.

Substitute parts are identified when equivalent electrical and mechanical parameters allow direct functional replacement within the same application category, maintaining identical output characteristics, supply voltage ranges, and physical mounting specifications.

Substiute Parts

DHR 200 C10
LEM USA Inc.In Stock: 1042DHR 200 C10 Datasheet
DHR 200 C10
Current Part
DHR 100 C10
LEM USA Inc.In Stock: 1151DHR 100 C10 Datasheet
DHR 100 C10
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number DHR 200 C10
Manufacturer LEM USA Inc.
Series DHR
Sensor Type Hall Effect, Open Loop
Current - Sensing 200A
Number of Channels 1
Output Ratiometric, 0 V ~ 10 V
Frequency Range DC ~ 6kHz
Linearity ±1%
Accuracy ±1%
Voltage - Supply 20V ~ 50V
Response Time 150ms
Current - Supply (Max) 30mA
Operating Temperature -40°C ~ 70°C
Polarization Bidirectional
Mounting Type Panel Mount
Package / Case Module
RoHS Status RoHS Compliant
REACH Status REACH Unaffected
Product Status Active

Substitute Part Grouping Explanation

Substitution eligibility for the DHR 200 C10 is determined by strict adherence to the following critical parameters:

Mandatory Matching Parameters:

  • Sensor Type: Hall Effect, Open Loop
  • Output Specification: Ratiometric, 0 V ~ 10 V
  • Frequency Range: DC ~ 6kHz
  • Linearity: ±1%
  • Accuracy: ±1%
  • Voltage - Supply: 20V ~ 50V
  • Response Time: 150ms
  • Current - Supply (Max): 30mA
  • Operating Temperature: -40°C ~ 70°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module
  • Manufacturer: LEM USA Inc.
  • Series: DHR

Variable Parameter (Application-Dependent):

  • Current - Sensing: 200A (primary specification; lower ratings available for reduced current measurement applications)

The DHR 100 C10 qualifies as a parametric equivalent substitute when the application requires measurement of currents up to 100A instead of 200A, with all other electrical and mechanical characteristics remaining identical.

Parameter Comparison

Parameter DHR 200 C10 DHR 100 C10 Compatibility
Manufacturer Part Number DHR 200 C10 DHR 100 C10 Same Series
Manufacturer LEM USA Inc. LEM USA Inc. Identical
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop Identical
Current - Sensing 200A 100A Different Rating
Number of Channels 1 1 Identical
Output Ratiometric, 0 V ~ 10 V Ratiometric, 0 V ~ 10 V Identical
Frequency Range DC ~ 6kHz DC ~ 6kHz Identical
Linearity ±1% ±1% Identical
Accuracy ±1% ±1% Identical
Voltage - Supply 20V ~ 50V 20V ~ 50V Identical
Response Time 150ms 150ms Identical
Current - Supply (Max) 30mA 30mA Identical
Operating Temperature -40°C ~ 70°C -40°C ~ 70°C Identical
Polarization Bidirectional Bidirectional Identical
Mounting Type Panel Mount Panel Mount Identical
Package / Case Module Module Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
REACH Status REACH Unaffected REACH Unaffected Identical
Product Status Active Active Identical

Engineering Selection Recommendations

DHR 200 C10 Primary Selection: Select the DHR 200 C10 for applications requiring measurement of AC/DC currents up to 200A. This part maintains Active product status with full RoHS compliance and REACH unaffected certification, ensuring regulatory compliance for industrial and commercial deployments.

DHR 100 C10 Substitute Selection: The DHR 100 C10 functions as a direct parametric equivalent when the application current measurement requirement does not exceed 100A. Both parts share identical electrical characteristics (output voltage, frequency response, accuracy, linearity), supply voltage specifications (20V ~ 50V), thermal operating range (-40°C ~ 70°C), and physical mounting configuration (Panel Mount Module). Both maintain Active status with equivalent compliance certifications.

Compliance Basis: Selection between these parts is determined solely by the maximum current measurement requirement of the application. All other functional parameters, environmental specifications, and regulatory certifications remain constant across both models within the DHR series.

Frequently Asked Questions (FAQ)

Q: Can the DHR 100 C10 replace the DHR 200 C10 in all applications?

A: The DHR 100 C10 functions as a direct substitute only when the application's maximum current measurement requirement does not exceed 100A. If the application requires measurement of currents between 100A and 200A, the DHR 200 C10 is the required selection. All other electrical and mechanical parameters are identical.

Q: Are the output voltage ranges identical between DHR 200 C10 and DHR 100 C10?

A: Yes. Both parts deliver ratiometric output of 0 V ~ 10 V across their respective current sensing ranges. The output voltage scaling differs proportionally to the current rating difference.

Q: Do both parts require identical supply voltage specifications?

A: Yes. Both the DHR 200 C10 and DHR 100 C10 operate with supply voltage range of 20V ~ 50V and maximum supply current of 30mA.

Q: Are the frequency response characteristics the same?

A: Yes. Both parts operate across the DC ~ 6kHz frequency range with identical 150ms response time.

Q: What is the operating temperature range for both parts?

A: Both the DHR 200 C10 and DHR 100 C10 operate across -40°C ~ 70°C.

Q: Are both parts RoHS compliant?

A: Yes. Both the DHR 200 C10 and DHR 100 C10 are RoHS Compliant with REACH Unaffected status.

Q: Is the mounting configuration identical?

A: Yes. Both parts are Panel Mount modules with identical physical package specifications.

Q: What accuracy and linearity specifications apply to both parts?

A: Both parts maintain ±1% linearity and ±1% accuracy specifications.