Request Quote
(Ships tomorrow)
DC010NGR5 Pressure Sensor Equivalent & Substitute Parts
Part Overview
The DC010NGR5 is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications requiring low-pressure measurement up to 0.36 PSI (2.49 kPa). This sensor features analog voltage output, temperature compensation, and operates across a wide temperature range of -25°C to 85°C.
The DC010NGR5 carries an obsolete product status. Identifying equivalent and substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing production requirements for applications utilizing this sensor specification.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Honeywell Sensing and Productivity Solutions |
| Pressure Range (Operating) | 0.36 PSI (2.49 kPa) |
| Pressure Type | Vented Gauge |
| Output Type | Analog Voltage |
| Accuracy | ±0.25% |
| Port Size | Male - 0.19" (4.83 mm) Tube, Dual |
| Port Style | Barbed |
| Mounting Type | Through Hole |
| Package Type | 4-SIP Module |
| Operating Temperature | -25°C to 85°C |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution of the DC010NGR5 is based on the following critical parameters that must align between the main part and substitute candidates:
Pressure Measurement Compatibility:
- Operating pressure range of 0.36 PSI (2.49 kPa) must be maintained
- Vented gauge pressure type must be preserved
- Accuracy specification of ±0.25% must be met or exceeded
Electrical and Output Compatibility:
- Analog voltage output type is required
- Supply voltage must be compatible with system design (5V nominal)
- Output voltage range must be compatible with downstream signal conditioning
Mechanical and Interface Compatibility:
- Port size of 0.19" (4.8 mm) tube, dual configuration
- Through hole mounting type for PCB integration
- 4-SIP package footprint for board layout compatibility
Environmental and Compliance:
- Operating temperature range must cover or exceed -25°C to 85°C
- RoHS compliance status must be maintained
- Temperature compensation feature must be present
The SSCSNBN010NGAA5 meets these substitution criteria while offering enhanced specifications and active product status.
Parameter Comparison
| Parameter | DC010NGR5 (Main Part) | SSCSNBN010NGAA5 (Substitute) |
|---|---|---|
| Manufacturer | Honeywell Sensing and Productivity Solutions | Honeywell Sensing and Productivity Solutions |
| Product Status | Obsolete | Active |
| Operating Pressure | 0.36 PSI (2.49 kPa) | 0.36 PSI (2.49 kPa) |
| Pressure Type | Vented Gauge | Vented Gauge |
| Output Type | Analog Voltage | Analog Voltage |
| Output Voltage Range | 1 V ~ 6 V | 0.5 V ~ 4.5 V |
| Supply Voltage | 5 V | 4.95 V ~ 5.05 V |
| Accuracy | ±0.25% | ±0.25% |
| Port Size | Male - 0.19" (4.83 mm) Tube, Dual | Male - 0.19" (4.8 mm) Tube, Dual |
| Port Style | Barbed | Barbless |
| Maximum Pressure | 5.42 PSI (37.38 kPa) | 10.84 PSI (74.75 kPa) |
| Operating Temperature | -25°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole |
| Package Type | 4-SIP Module | 4-SIP, Dual Ports, Same Side |
| Temperature Compensation | Yes | Yes |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
SSCSNBN010NGAA5 as Primary Substitute:
The SSCSNBN010NGAA5 is the direct substitute for the obsolete DC010NGR5. Both sensors are manufactured by Honeywell Sensing and Productivity Solutions and share identical pressure measurement specifications (0.36 PSI operating pressure, ±0.25% accuracy, vented gauge type).
The SSCSNBN010NGAA5 carries active product status, ensuring long-term availability and supply chain continuity. This part maintains RoHS compliance and MSL Level 1 rating, meeting the same environmental and regulatory requirements as the original part.
Key Compatibility Considerations:
The substitute part operates with a tighter supply voltage tolerance (4.95 V ~ 5.05 V versus 5 V nominal) and produces a different output voltage range (0.5 V ~ 4.5 V versus 1 V ~ 6 V). System designs must accommodate this output voltage shift through signal conditioning adjustments or firmware recalibration of analog-to-digital conversion parameters.
The SSCSNBN010NGAA5 features barbless port design compared to the barbed ports of the DC010NGR5. Tubing connection methods must be verified for compatibility with the new port configuration.
The substitute part provides enhanced maximum pressure rating (10.84 PSI versus 5.42 PSI) and extended low-temperature operation (-40°C versus -25°C), offering improved performance margins for demanding applications.
Frequently Asked Questions (FAQ)
Q: Can the SSCSNBN010NGAA5 directly replace the DC010NGR5 without circuit modifications?
A: The SSCSNBN010NGAA5 maintains identical pressure measurement range and accuracy specifications. However, the output voltage range differs (0.5 V ~ 4.5 V versus 1 V ~ 6 V), requiring signal conditioning or analog-to-digital conversion parameter adjustments in the receiving circuit.
Q: What is the impact of the different port styles (barbed versus barbless)?
A: The DC010NGR5 features barbed ports designed for push-fit tubing connections with mechanical retention. The SSCSNBN010NGAA5 uses barbless ports requiring alternative connection methods such as compression fittings or hose clamps. Tubing interface compatibility must be verified during design transition.
Q: Are both sensors suitable for the same operating temperature range?
A: The DC010NGR5 operates from -25°C to 85°C. The SSCSNBN010NGAA5 extends the lower temperature limit to -40°C, providing broader environmental coverage. Both sensors maintain operation across the upper temperature limit of 85°C.
Q: What is the significance of the active product status for the SSCSNBN010NGAA5?
A: Active product status indicates that the SSCSNBN010NGAA5 is currently manufactured and supported by Honeywell Sensing and Productivity Solutions. This ensures ongoing availability, technical support, and supply chain reliability, addressing the obsolescence risk associated with the DC010NGR5.
Q: Do both sensors meet the same compliance and environmental standards?
A: Both the DC010NGR5 and SSCSNBN010NGAA5 are RoHS compliant and carry MSL Level 1 (Unlimited) moisture sensitivity rating. Both are classified under ECCN EAR99 and HTSUS 9026.20.4000, maintaining equivalent regulatory and compliance status.
Q: What is the difference in maximum pressure rating between these sensors?
A: The DC010NGR5 has a maximum pressure rating of 5.42 PSI (37.38 kPa), while the SSCSNBN010NGAA5 is rated to 10.84 PSI (74.75 kPa). The substitute part provides double the overpressure protection margin, beneficial for applications subject to transient pressure spikes.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts