Equivalent & Substitute Parts for D4GL-4CFA-A4

Part Overview

The D4GL-4CFA-A4 is an interlock solenoid release switch manufactured by Omron Automation and Safety. This DPST (Double Pole Single Throw) device operates at 240VAC with 24VDC supply voltage and provides a holding force of 102kgf. The unit features a panel disconnect actuator type with screw terminal connections, M20 conduit thread size, and IP67 ingress protection rating suitable for dust-tight and waterproof applications.

The D4GL-4CFA-A4 is classified as obsolete. Identifying equivalent substitute parts is necessary to maintain system functionality and ensure continued availability for replacement and maintenance applications.

Substiute Parts

D4GL-4CFA-A4
Omron Automation and SafetyIn Stock: 1143D4GL-4CFA-A4 Datasheet
D4GL-4CFA-A4
Current Part
D4SL-N4CFA
Omron Automation and SafetyIn Stock: 786D4SL-N4CFA Datasheet
D4SL-N4CFA
Similar
D4SL-N4CFA-N
Omron Automation and SafetyIn Stock: 811D4SL-N4CFA-N Datasheet
D4SL-N4CFA-N
Similar

Key Parameters

Parameter D4GL-4CFA-A4
Manufacturer Omron Automation and Safety
Series D4GL
Product Status Obsolete
Type Solenoid Release
Circuit Configuration DPST-NO/NC + DPST-NC
Current Rating 750mA (AC)
Voltage Rating 240VAC
Supply Voltage 24VDC
Holding Force 102kgf
Actuator Type Panel Disconnect
Termination Style Screw Terminal
Conduit Thread Size M20
Operating Temperature -10°C ~ 55°C
Ingress Protection IP67 - Dust Tight, Waterproof
Approval Agencies CE, cULus, TUV
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute parts for the D4GL-4CFA-A4 are identified from the D4SL-N series, which maintains functional equivalence based on the following criteria:

Common Parameters (Substitution Basis):

  • Manufacturer: Omron Automation and Safety
  • Type: Solenoid Release
  • Circuit Configuration: DPST-NO/NC + DPST-NC
  • Actuator Type: Panel Disconnect
  • Conduit Thread Size: M20
  • Operating Temperature Range: -10°C ~ 55°C
  • Ingress Protection: IP67 - Dust Tight, Waterproof
  • Moisture Sensitivity Level: 1 (Unlimited)

Substitute Parts Identified:

  1. D4SL-N4CFA (Active status, screw terminal)
  2. D4SL-N4CFA-N (Active status, connector termination)

Both substitute parts are from the active D4SL-N series and share the core functional characteristics and environmental specifications of the obsolete D4GL-4CFA-A4.

Parameter Comparison

Parameter D4GL-4CFA-A4 D4SL-N4CFA D4SL-N4CFA-N
Manufacturer Omron Automation and Safety Omron Automation and Safety Omron Automation and Safety
Series D4GL D4SL-N D4SL-N
Product Status Obsolete Active Active
Type Solenoid Release Solenoid Release Solenoid Release
Circuit Configuration DPST-NO/NC + DPST-NC DPST-NO/NC + DPST-NC DPST-NO/NC + DPST-NC
Current Rating (AC) 750mA 1.5A 1.5A
Current Rating (DC) 220mA 220mA
Voltage Rating 240VAC 120VAC, 125VDC 120VAC, 125VDC
Holding Force 102kgf 6kgf 6kgf
Actuator Type Panel Disconnect Panel Disconnect Panel Disconnect
Termination Style Screw Terminal Screw Terminal Connector
Conduit Thread Size M20 M20 M20
Operating Temperature -10°C ~ 55°C -10°C ~ 55°C -10°C ~ 55°C
Ingress Protection IP67 IP67 IP67
Approval Agencies CE, cULus, TUV CCC, CE, cURus, TUV CCC, CE, cURus, TUV
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The D4GL-4CFA-A4 is obsolete and no longer in active production. The D4SL-N series provides functional equivalents with active product status and current manufacturing support.

D4SL-N4CFA is the primary substitute when screw terminal connections are required. This part maintains the same termination style as the original D4GL-4CFA-A4 and is suitable for direct replacement in applications where screw-based wiring is specified.

D4SL-N4CFA-N is the alternative substitute when connector-based termination is acceptable or preferred. This variant offers the same functional performance with connector-style connections, which may simplify installation and maintenance procedures.

Both substitute parts carry expanded regulatory approvals (CCC, CE, cURus, TUV) compared to the original part, ensuring compliance with current international standards. The D4SL-N series is actively manufactured and supported by Omron Automation and Safety.

Note that the D4SL-N series operates at lower voltage ratings (120VAC, 125VDC) and reduced holding force (6kgf) compared to the D4GL-4CFA-A4 (240VAC, 102kgf). Application-specific electrical and mechanical requirements must be evaluated before final part selection.

Frequently Asked Questions (FAQ)

Q: Can D4SL-N4CFA and D4SL-N4CFA-N be used interchangeably?

A: Both parts share identical electrical and mechanical specifications. The only difference is termination style: D4SL-N4CFA uses screw terminals, while D4SL-N4CFA-N uses connector termination. Selection depends on the wiring method required by your application.

Q: What are the key differences between the D4GL-4CFA-A4 and D4SL-N substitutes?

A: The primary differences are voltage rating (240VAC vs. 120VAC) and holding force (102kgf vs. 6kgf). Both maintain identical circuit configuration, actuator type, conduit thread size, operating temperature range, and IP67 ingress protection. Verify that your application can operate within the D4SL-N electrical and mechanical specifications.

Q: Why is the D4GL-4CFA-A4 classified as obsolete?

A: The D4GL-4CFA-A4 has been discontinued by Omron Automation and Safety. The D4SL-N series represents the current active product line for equivalent solenoid release functionality.

Q: Are the substitute parts certified to the same standards?

A: The D4SL-N series carries certifications from CCC, CE, cURus, and TUV, which includes all certifications held by the original D4GL-4CFA-A4 (CE, cULus, TUV). The expanded certification list reflects current regulatory requirements.

Q: What is the impact of reduced holding force in the D4SL-N series?

A: The D4SL-N series provides 6kgf holding force compared to 102kgf in the D4GL-4CFA-A4. This reduction is significant and must be evaluated against your application's mechanical requirements. If high holding force is critical, alternative solutions outside the D4SL-N series may be necessary.

Q: Can I use D4SL-N parts in a 240VAC system designed for the D4GL-4CFA-A4?

A: No. The D4SL-N series is rated for 120VAC maximum. Direct substitution in a 240VAC system is not permitted. System redesign or alternative parts must be considered.

Request Quote (Ships tomorrow)