Part Overview
The Omron D4GL-2AFA-A is an interlock solenoid release switch designed for panel disconnect applications with dual-pole, single-throw (DPST) configuration. This component operates at 240VAC with 24VDC supply voltage and provides a holding force of 102kgf. The D4GL-2AFA-A is classified as obsolete, making identification of active equivalent parts essential for system maintenance, repair, and new design implementations where functional compatibility is required.
Substiute Parts
Key Parameters
| Parameter | D4GL-2AFA-A |
|---|---|
| Manufacturer | Omron Automation and Safety |
| Series | D4GL |
| Product Status | Obsolete |
| Type | Solenoid Release |
| Circuit Configuration | DPST-NO/NC (DB/DM) x 2 |
| Current Rating (AC) | 750mA |
| Voltage Rating | 240VAC |
| Supply Voltage | 24VDC |
| Holding Force | 102kgf |
| Actuator Type | Panel Disconnect |
| Termination Style | Screw Terminal |
| Conduit Thread Size | G1/2 |
| Operating Temperature Range | -10°C to 55°C |
| Ingress Protection | IP67 - Dust Tight, Waterproof |
| Approvals | CE, cULus, TUV |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the D4GL-2AFA-A is based on functional equivalence within the Omron solenoid release product family. The substitute parts identified are from the D4SL-N series, which maintains the same circuit configuration (DPST-NO/NC), actuator type (Panel Disconnect), conduit thread size (G1/2), operating temperature range (-10°C to 55°C), ingress protection rating (IP67), and moisture sensitivity level (MSL 1).
The D4SL-N series represents the active product line replacement for the obsolete D4GL series. Both substitute parts—D4SL-N2AFA and D4SL-N2AFA-N—share identical electrical and mechanical specifications with the following exceptions:
Current Rating: D4SL-N series rated at 1.5A (AC) and 220mA (DC), compared to D4GL-2AFA-A at 750mA (AC)
Voltage Rating: D4SL-N series operates at 120VAC and 125VDC, whereas D4GL-2AFA-A operates at 240VAC and 24VDC
Holding Force: D4SL-N series provides 6kgf holding force versus 102kgf for D4GL-2AFA-A
Termination Style: D4SL-N2AFA uses Screw Terminal (matching D4GL-2AFA-A), while D4SL-N2AFA-N uses Connector termination
The key differentiator between the two D4SL-N substitutes is termination style. Selection between D4SL-N2AFA and D4SL-N2AFA-N depends on whether screw terminal or connector-based integration is required in the target application.
Parameter Comparison
| Parameter | D4GL-2AFA-A (Main) | D4SL-N2AFA | D4SL-N2AFA-N |
|---|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety | Omron Automation and Safety |
| Product Status | Obsolete | Active | Active |
| Type | Solenoid Release | Solenoid Release | Solenoid Release |
| Circuit Configuration | DPST-NO/NC (DB/DM) x 2 | DPST-NO/NC (DB/DM) x 2 | DPST-NO/NC (DB/DM) x 2 |
| Current Rating (AC) | 750mA | 1.5A | 1.5A |
| Current Rating (DC) | Not specified | 220mA | 220mA |
| Voltage Rating | 240VAC | 120VAC, 125VDC | 120VAC, 125VDC |
| Holding Force | 102kgf | 6kgf | 6kgf |
| Actuator Type | Panel Disconnect | Panel Disconnect | Panel Disconnect |
| Termination Style | Screw Terminal | Screw Terminal | Connector |
| Conduit Thread Size | G1/2 | G1/2 | G1/2 |
| Operating Temperature Range | -10°C to 55°C | -10°C to 55°C | -10°C to 55°C |
| Ingress Protection | IP67 | IP67 | IP67 |
| Approvals | CE, cULus, TUV | CCC, CE, cURus, TUV | CCC, CE, cURus, TUV |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
Selection between D4SL-N2AFA and D4SL-N2AFA-N should be based on termination requirements and system integration approach. D4SL-N2AFA is appropriate for applications requiring screw terminal connections, maintaining direct compatibility with existing wiring harnesses designed for the D4GL-2AFA-A. D4SL-N2AFA-N is suitable for connector-based integration, offering simplified assembly and potential for standardized connector interfaces in modern panel designs.
Both D4SL-N variants carry active product status with expanded regulatory approvals (CCC, CE, cURus, TUV) compared to the obsolete D4GL-2AFA-A (CE, cULus, TUV). This expanded certification profile supports deployment in broader geographic and regulatory markets.
Critical consideration: The D4SL-N series exhibits reduced holding force (6kgf versus 102kgf) and operates at lower voltage ratings (120VAC/125VDC versus 240VAC/24VDC). Applications dependent on the higher holding force specification of the D4GL-2AFA-A require engineering evaluation to confirm that the D4SL-N series mechanical performance is adequate for the intended load conditions.
Frequently Asked Questions (FAQ)
Q: Can D4SL-N2AFA and D4SL-N2AFA-N be used interchangeably?
A: Both parts share identical electrical and mechanical specifications. The only difference is termination style: D4SL-N2AFA uses screw terminals while D4SL-N2AFA-N uses connector termination. Selection depends on the connection method required by your application. They cannot be physically interchanged without rewiring or adapter modifications.
Q: What is the primary difference between the D4GL-2AFA-A and D4SL-N series?
A: The D4GL-2AFA-A is obsolete, while D4SL-N variants are active products. The D4SL-N series operates at lower voltage ratings (120VAC/125VDC versus 240VAC/24VDC), carries higher AC current capacity (1.5A versus 750mA), and provides lower holding force (6kgf versus 102kgf). Both maintain identical circuit configuration, actuator type, and environmental protection ratings.
Q: Are there holding force implications when substituting the D4GL-2AFA-A?
A: Yes. The D4GL-2AFA-A provides 102kgf holding force, while D4SL-N substitutes provide 6kgf. Applications where the higher holding force is critical to system operation require engineering assessment to confirm the D4SL-N series is mechanically adequate for the intended load.
Q: Do the substitute parts have the same regulatory approvals?
A: The D4SL-N series carries expanded approvals (CCC, CE, cURus, TUV) compared to the D4GL-2AFA-A (CE, cULus, TUV). This broader certification profile supports compliance in additional regulatory jurisdictions.
Q: Which substitute part should I select for a direct replacement?
A: D4SL-N2AFA is the direct replacement if your application uses screw terminal connections. D4SL-N2AFA-N is appropriate if connector-based termination is preferred or required by your system design.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts