CX-491-P-Y Equivalent & Substitute Parts

Part Overview

The CX-491-P-Y is a retroreflective optical sensor manufactured by Panasonic Industrial Automation Sales, designed for 3-meter (118.110") detection range applications with PNP open-collector output. This sensor operates across 12V to 24V supply voltage with 1ms response time and IP67 ingress protection, suitable for industrial automation environments. The product is currently obsolete, making identification of compatible substitute parts essential for system maintenance and replacement planning.

Substiute Parts

CX-491-P-Y
Panasonic Industrial Automation SalesIn Stock: 1027CX-491-P-Y Datasheet
CX-491-P-Y
Current Part
CX-491-P
Panasonic Industrial Automation SalesIn Stock: 848CX-491-P Datasheet
CX-491-P
Direct

Key Parameters

Parameter CX-491-P-Y Value
Sensing Method Retroreflective
Sensing Distance 118.110" (3m)
Voltage - Supply 12V ~ 24V
Output Configuration PNP - Open Collector
Light Source Red LED
Response Time 1ms
Ingress Protection IP67
Operating Temperature -25°C ~ 55°C
Connection Method Cable
Cable Length 196.85" (5m)
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the CX-491-P-Y is determined by strict alignment across the following critical parameters:

Mandatory Matching Parameters:

  • Sensing Method: Retroreflective
  • Output Configuration: PNP - Open Collector
  • Light Source: Red LED
  • Voltage - Supply: 12V ~ 24V
  • Response Time: 1ms
  • Ingress Protection: IP67
  • Operating Temperature: -25°C ~ 55°C
  • Connection Method: Cable
  • Cable Length: 196.85" (5m)

Allowable Variation:

  • Sensing Distance: The CX-491-P-Y operates at 3m (118.110"). The substitute CX-491-P operates at 5m (16.40'), representing an extended detection range within the same sensor family. Extended range capability maintains backward compatibility for applications requiring shorter detection distances.

The CX-491-P qualifies as a direct substitute based on identical electrical characteristics, mechanical interface, environmental ratings, and response performance, with the distinction of increased sensing distance capability.

Parameter Comparison

Parameter CX-491-P-Y CX-491-P Compatibility
Sensing Method Retroreflective Retroreflective Identical
Sensing Distance 118.110" (3m) 16.40' (5m) Extended Range
Voltage - Supply 12V ~ 24V 12V ~ 24V Identical
Output Configuration PNP - Open Collector PNP - Open Collector Identical
Light Source Red LED Red LED Identical
Response Time 1ms 1ms Identical
Ingress Protection IP67 IP67 Identical
Operating Temperature -25°C ~ 55°C -25°C ~ 55°C Identical
Connection Method Cable Cable Identical
Cable Length 196.85" (5m) 196.85" (5m) Identical
RoHS Status RoHS Compliant ROHS3 Compliant Both Compliant
Product Status Obsolete Active Active Alternative Available

Engineering Selection Recommendations

The CX-491-P serves as the active production equivalent for the obsolete CX-491-P-Y. Both sensors share identical electrical specifications, mechanical interfaces, and environmental performance characteristics. The primary distinction is the extended sensing distance of the CX-491-P (5m versus 3m), which provides increased detection range capability without compromising any other functional parameter.

From a compliance perspective, the CX-491-P meets ROHS3 requirements, representing current regulatory standards, whereas the CX-491-P-Y meets RoHS Compliant specifications. The CX-491-P is currently in active production status with confirmed inventory availability (800 pcs), ensuring supply chain continuity for replacement and new system deployments.

For applications currently using the CX-491-P-Y, direct substitution with the CX-491-P is supported across all electrical, mechanical, and environmental operating conditions. The extended sensing distance of the CX-491-P does not introduce incompatibility; it expands the operational envelope of the sensor.

Frequently Asked Questions (FAQ)

Q: Can the CX-491-P directly replace the CX-491-P-Y in existing installations?

A: Yes. The CX-491-P is electrically and mechanically compatible with the CX-491-P-Y. Both sensors feature identical 12V-24V supply voltage, PNP open-collector output, 1ms response time, IP67 protection, and cable interface specifications. The extended 5m sensing distance of the CX-491-P does not create incompatibility with existing wiring or control logic.

Q: What is the primary difference between these two sensors?

A: The CX-491-P extends the sensing distance to 5m (16.40'), compared to the 3m (118.110") range of the CX-491-P-Y. All other electrical, mechanical, and environmental parameters remain identical. The CX-491-P is the active production model.

Q: Are there any compliance differences between the CX-491-P-Y and CX-491-P?

A: The CX-491-P-Y carries RoHS Compliant certification, while the CX-491-P carries ROHS3 Compliant certification. Both meet current regulatory requirements. The CX-491-P represents the current standard for new deployments.

Q: What is the cable length for both sensors?

A: Both the CX-491-P-Y and CX-491-P feature a 196.85" (5m) cable length with cable connection method.

Q: Is the CX-491-P-Y still available for purchase?

A: The CX-491-P-Y is classified as obsolete. The CX-491-P is the active production substitute with current inventory availability. For new system designs or replacements, the CX-491-P is the recommended selection.

Q: Do both sensors operate across the same temperature range?

A: Yes. Both the CX-491-P-Y and CX-491-P operate across -25°C to 55°C, ensuring compatibility across identical environmental conditions.

Request Quote (Ships tomorrow)