CR6002AC Equivalent & Substitute Parts

Part Overview

The CR6002AC is a Transient Voltage Suppressor (TVS) diode manufactured by Littelfuse, designed for general-purpose overvoltage protection in through-hole applications. This component features a 275V reverse standoff voltage rating and operates across an extended temperature range of -55°C to 175°C. The CR6002AC is classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing system support and new design implementations.

Substiute Parts

CR6002AC
LittelfuseIn Stock: 1138CR6002AC Datasheet
CR6002AC
Current Part
P6002ACL
Littelfuse Inc.In Stock: 779826P6002ACL Datasheet
P6002ACL
MFR Recommended

Key Parameters

Parameter CR6002AC
Manufacturer Littelfuse
Category Transient Voltage Suppressors (TVS)
Type Zener
Bidirectional Channels 2
Voltage - Reverse Standoff (Typ) 275V
Voltage - Breakdown (Min) 350V
Operating Temperature -55°C ~ 175°C (TJ)
Mounting Type Through Hole
Package / Case 3-SIP
Supplier Device Package TO-220 Modified
Product Status Obsolete
RoHS Status RoHS non-compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

The P6002ACL is identified as the manufacturer-recommended substitute for the CR6002AC. Substitution eligibility is determined by the following critical parameters:

  • Voltage Rating Compatibility: Both parts maintain a 275V off-state voltage specification, ensuring equivalent protection thresholds in the protected circuit.
  • Bidirectional Protection: Both components provide dual-channel protection in a single package.
  • Package Compatibility: Both parts utilize the 3-SIP TO-220 Modified package, enabling direct mechanical and electrical interchange without PCB redesign.
  • Mounting Type: Both are through-hole components, maintaining compatibility with existing assembly processes.
  • Temperature Range: The P6002ACL supports the same extended operating temperature range (-55°C to 175°C), ensuring thermal performance equivalence.

Parameter Comparison

Parameter CR6002AC P6002ACL
Manufacturer Littelfuse Littelfuse Inc.
Category Transient Voltage Suppressors (TVS) Transient Voltage Suppressors (TVS)
Type Zener TVS Thyristor (SIDACtor®)
Voltage - Reverse Standoff / Off State 275V 275V, 550V
Voltage - Breakdown / Breakover (Min) 350V 350V, 700V
Bidirectional Channels 2 2
Operating Temperature -55°C ~ 175°C (TJ) -55°C ~ 175°C (TJ)
Mounting Type Through Hole Through Hole
Package / Case 3-SIP 3-SIP
Supplier Device Package TO-220 Modified TO-220 Modified
Product Status Obsolete Active
RoHS Status RoHS non-compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The P6002ACL is the appropriate substitute for the CR6002AC based on the following factors:

  • Product Status: The CR6002AC is obsolete, while the P6002ACL maintains active production status, ensuring long-term availability and supply chain continuity.
  • Regulatory Compliance: The P6002ACL achieves ROHS3 compliance, whereas the CR6002AC is RoHS non-compliant. Selection of the P6002ACL aligns with current environmental and regulatory requirements.
  • Electrical Equivalence: Both components share identical voltage ratings (275V standoff/off-state) and bidirectional channel configuration, confirming functional interchangeability within the protected circuit.
  • Package Compatibility: The 3-SIP TO-220 Modified package is identical across both parts, permitting direct substitution without PCB modification.
  • REACH Status: The P6002ACL is REACH Unaffected, providing additional regulatory assurance for international applications.

Frequently Asked Questions (FAQ)

Q: Can the P6002ACL be used as a direct replacement for the CR6002AC without PCB modifications?

A: Yes. Both components utilize the identical 3-SIP TO-220 Modified package configuration, enabling direct pin-for-pin substitution without PCB redesign or layout changes.

Q: What is the primary difference between the CR6002AC and P6002ACL?

A: The CR6002AC is a Zener-type TVS diode, while the P6002ACL is a TVS Thyristor (SIDACtor®) technology. Both maintain equivalent 275V voltage ratings and bidirectional protection, but the P6002ACL offers active product status and ROHS3 compliance.

Q: Are the voltage ratings identical between these two parts?

A: The critical voltage specification—reverse standoff / off-state voltage—is identical at 275V for both components. The P6002ACL offers additional voltage options (550V off-state), but the 275V rating ensures direct functional equivalence.

Q: Does the P6002ACL support the same operating temperature range?

A: Yes. Both the CR6002AC and P6002ACL operate across -55°C to 175°C (TJ), maintaining thermal performance equivalence across all environmental conditions.

Q: What is the significance of the P6002ACL's ROHS3 compliance?

A: ROHS3 compliance indicates the P6002ACL meets current environmental regulations restricting hazardous substances. This is particularly important for new designs and applications subject to regulatory requirements, whereas the CR6002AC's RoHS non-compliant status limits its use in regulated environments.

Q: Are moisture sensitivity levels equivalent?

A: Yes. Both components are rated MSL 1 (Unlimited), indicating no moisture sensitivity restrictions for storage, handling, or assembly processes.

Request Quote (Ships tomorrow)