CPC05GFH Pressure Sensor: Equivalent & Substitute Parts

Part Overview

The CPC05GFH is a 5 PSI vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions. This component features a Wheatstone Bridge output configuration with 0 mV to 60 mV signal range at 12V supply, designed for board-mount applications with through-hole termination. The CPC05GFH is classified as obsolete, necessitating identification of active equivalent and substitute components that maintain functional compatibility within the 5 PSI pressure measurement range and similar electrical output characteristics.

Substiute Parts

CPC05GFH
Honeywell Sensing and Productivity SolutionsIn Stock: 911CPC05GFH Datasheet
CPC05GFH
Current Part
TSCSANN005PGUCV
Honeywell Sensing and Productivity SolutionsIn Stock: 905TSCSANN005PGUCV Datasheet
TSCSANN005PGUCV
Similar
5 PSI-GF-HGRADE-MINI
Amphenol All Sensors CorporationIn Stock: 8785 PSI-GF-HGRADE-MINI Datasheet
5 PSI-GF-HGRADE-MINI
Direct
5 PSI-GF-CGRADE-MINI
Amphenol All Sensors CorporationIn Stock: 9505 PSI-GF-CGRADE-MINI Datasheet
5 PSI-GF-CGRADE-MINI
Similar
5 PSI-GF-PRIME-MINI
Amphenol All Sensors CorporationIn Stock: 9935 PSI-GF-PRIME-MINI Datasheet
5 PSI-GF-PRIME-MINI
Similar

Key Parameters

Parameter CPC05GFH Value
Operating Pressure 5 PSI (34.47 kPa)
Pressure Type Vented Gauge
Output Type Wheatstone Bridge
Output Range 0 mV ~ 60 mV (12V)
Supply Voltage 3V ~ 16V
Accuracy ±2%
Port Size Male - 0.15" (3.8 mm) Tube
Port Style Barbed
Package Type 4-SIP Module
Mounting Type Through Hole
Operating Temperature -25°C ~ 85°C
Maximum Pressure 15 PSI (103.42 kPa)
Features Temperature Compensated
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution of the CPC05GFH is determined by strict alignment of the following critical parameters:

Primary Compatibility Criteria:

  • Operating pressure rating of 5 PSI (34.47 kPa)
  • Vented gauge pressure type
  • Wheatstone Bridge output configuration
  • 4-SIP module package with through-hole PC pin termination
  • Temperature compensation feature
  • RoHS compliance

Secondary Compatibility Criteria:

  • Output voltage range compatibility with 12V supply operation
  • Supply voltage range overlap with 3V to 16V specification
  • Operating temperature range coverage of -25°C to 85°C minimum
  • Port connection style (barbed or barbless tubing interfaces)

The substitute parts identified maintain the core 5 PSI pressure measurement function and Wheatstone Bridge signal conditioning. Variations in port tube diameter (0.15" to 0.19"), output voltage scaling (60 mV versus 25 mV), and accuracy specifications represent acceptable engineering trade-offs within the same functional category. All substitute parts retain active product status and full RoHS compliance.

Parameter Comparison

Parameter CPC05GFH 5 PSI-GF-PRIME-MINI 5 PSI-GF-HGRADE-MINI 5 PSI-GF-CGRADE-MINI TSCSANN005PGUCV
Manufacturer Honeywell Amphenol All Sensors Amphenol All Sensors Amphenol All Sensors Honeywell
Product Status Obsolete Active Active Active Active
Operating Pressure 5 PSI 5 PSI 5 PSI 5 PSI 5 PSI
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge
Output Type Wheatstone Bridge Wheatstone Bridge Wheatstone Bridge Wheatstone Bridge Wheatstone Bridge
Output Range 0-60 mV (12V) 0-60 mV (12V) 0-60 mV (12V) 0-60 mV (12V) 0-25 mV (5V)
Supply Voltage 3V ~ 16V 16V 16V 16V 1.5V ~ 12V
Accuracy ±2% ±0.25% ±0.5% ±1% ±0.15%
Port Size 0.15" (3.8 mm) 0.18" (4.57 mm) 0.18" (4.57 mm) 0.18" (4.57 mm) 0.19" (4.93 mm)
Port Style Barbed Barbless Barbless Barbless Barbed
Package Type 4-SIP Module 4-SIP Module 4-SIP Module 4-SIP Module 4-SIP, Side Port
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole
Operating Temperature -25°C ~ 85°C -25°C ~ 85°C -25°C ~ 85°C -25°C ~ 85°C -40°C ~ 85°C
Maximum Pressure 15 PSI 20 PSI 20 PSI 20 PSI 30 PSI
Temperature Compensated Yes Yes Yes Yes Yes
RoHS Compliant Yes Yes Yes Yes Yes

Engineering Selection Recommendations

Direct Substitutes (Amphenol All Sensors ACPC Series):

The 5 PSI-GF-PRIME-MINI, 5 PSI-GF-HGRADE-MINI, and 5 PSI-GF-CGRADE-MINI represent direct functional equivalents to the CPC05GFH. All three components are active products with identical 5 PSI operating pressure, Wheatstone Bridge output at 0-60 mV (12V), 4-SIP through-hole package configuration, and temperature compensation. These parts differ only in accuracy specification (±0.25%, ±0.5%, and ±1% respectively) and port tube diameter (0.18" versus 0.15"). The barbless port style requires tubing adapter consideration during mechanical integration. Selection among these three should be based on accuracy requirements and available inventory.

Alternative Substitute (Honeywell TruStability TSC Series):

The TSCSANN005PGUCV maintains the same manufacturer lineage as the CPC05GFH and offers superior accuracy (±0.15%) with extended maximum pressure rating (30 PSI). This component operates at reduced output voltage (0-25 mV at 5V) and features a wider supply voltage range (1.5V-12V). The 0.19" port diameter and side-port 4-SIP configuration require mechanical interface verification. This option is suitable for applications requiring higher accuracy and lower supply voltage operation.

Compliance and Availability:

All substitute parts maintain RoHS compliance and active product status. Inventory availability ranges from 797 to 942 units across the Amphenol options, with 895 units available for the Honeywell TSCSANN005PGUCV. Selection should account for supply chain continuity and long-term component availability.

Frequently Asked Questions (FAQ)

Q: Can the 5 PSI-GF-PRIME-MINI directly replace the CPC05GFH without circuit modification?

A: The 5 PSI-GF-PRIME-MINI maintains identical output voltage range (0-60 mV at 12V) and supply voltage compatibility (16V within the 3V-16V specification). Direct electrical substitution is supported. Mechanical integration requires verification of the 0.18" barbless port interface against the original 0.15" barbed connection.

Q: What is the significance of the port tube diameter difference between 0.15" and 0.18"?

A: Port tube diameter affects tubing compatibility and pressure coupling interface. The CPC05GFH uses 0.15" barbed connections; substitute parts use 0.18" barbless connections. Tubing adapters or reconfigured pressure line connections are required for mechanical integration.

Q: Why does the TSCSANN005PGUCV have a different output voltage range (0-25 mV versus 0-60 mV)?

A: The TSCSANN005PGUCV operates at 5V supply voltage, resulting in proportionally reduced output voltage scaling. Signal conditioning circuits must accommodate this lower voltage range. The 5 PSI pressure measurement function remains identical.

Q: Are all substitute parts temperature compensated?

A: Yes. All identified substitute parts include temperature compensation features across their operating temperature ranges. The TSCSANN005PGUCV extends the lower temperature limit to -40°C compared to the CPC05GFH specification of -25°C.

Q: What accuracy improvement is achieved by selecting the 5 PSI-GF-PRIME-MINI over the CPC05GFH?

A: The 5 PSI-GF-PRIME-MINI provides ±0.25% accuracy compared to the CPC05GFH ±2% specification, representing an 8-fold improvement in measurement precision within the same 5 PSI pressure range.

Q: Is the side-port configuration of the TSCSANN005PGUCV compatible with standard through-hole PCB layouts?

A: The TSCSANN005PGUCV maintains through-hole PC pin termination compatible with standard PCB mounting. The side-port designation refers to the pressure port location on the sensor body, not the electrical termination. PCB layout compatibility is maintained.

Q: Can multiple substitute parts be used interchangeably within the same application?

A: The Amphenol 5 PSI-GF series (PRIME-MINI, HGRADE-MINI, CGRADE-MINI) are interchangeable from electrical and mechanical perspectives, differing only in accuracy specification. The TSCSANN005PGUCV requires circuit-level verification due to reduced output voltage scaling and different supply voltage characteristics.

Request Quote (Ships tomorrow)