Part Overview

The CMB-153-11C3B-B-A is a thermal circuit breaker manufactured by Carling Technologies, rated for 15A at 250V AC and 32V DC. This single-pole, panel-mount device features push-to-reset actuation and is designed for overcurrent protection in industrial and commercial applications. The part maintains Active product status with full compliance to CE, cUL, TUV, UL1077, and UL1500 standards. Substitute parts are identified to provide alternative sourcing options when the primary part is unavailable or when design flexibility permits component selection from qualified manufacturers.

Substiute Parts

CMB-153-11C3B-B-A
Carling TechnologiesIn Stock: 1056CMB-153-11C3B-B-A Datasheet
CMB-153-11C3B-B-A
Current Part
CBW57-EJ-15A
OptiFuseIn Stock: 1480CBW57-EJ-15A Datasheet
CBW57-EJ-15A
Parametric Equivalent
CBW57-EL4-15A
OptiFuseIn Stock: 1237CBW57-EL4-15A Datasheet
CBW57-EL4-15A
Parametric Equivalent
CBW57-ES-15A
OptiFuseIn Stock: 3587CBW57-ES-15A Datasheet
CBW57-ES-15A
Parametric Equivalent
CBW57-ES-15A-5X
OptiFuseIn Stock: 1179CBW57-ES-15A-5X Datasheet
CBW57-ES-15A-5X
Parametric Equivalent
CBW57-GS-15A-WB
OptiFuseIn Stock: 1025CBW57-GS-15A-WB Datasheet
CBW57-GS-15A-WB
Parametric Equivalent
CBW57-HB-15A-P
OptiFuseIn Stock: 8858CBW57-HB-15A-P Datasheet
CBW57-HB-15A-P
Parametric Equivalent
CBW57-HS-15A-5X
OptiFuseIn Stock: 1878CBW57-HS-15A-5X Datasheet
CBW57-HS-15A-5X
Parametric Equivalent
CBW57-PB-15A
OptiFuseIn Stock: 930CBW57-PB-15A Datasheet
CBW57-PB-15A
Parametric Equivalent
CBW57-PB-15A-5X
OptiFuseIn Stock: 1958CBW57-PB-15A-5X Datasheet
CBW57-PB-15A-5X
Parametric Equivalent
CBW57-PB-15A-WX
OptiFuseIn Stock: 1036CBW57-PB-15A-WX Datasheet
CBW57-PB-15A-WX
Parametric Equivalent
CBW57-PS-15A
OptiFuseIn Stock: 1852CBW57-PS-15A Datasheet
CBW57-PS-15A
Parametric Equivalent
CBW57-PS-15A-1X
OptiFuseIn Stock: 2144CBW57-PS-15A-1X Datasheet
CBW57-PS-15A-1X
Parametric Equivalent
CBW57-PS-15A-5X
OptiFuseIn Stock: 1056CBW57-PS-15A-5X Datasheet
CBW57-PS-15A-5X
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Carling Technologies
Part Number CMB-153-11C3B-B-A
Series CMB
Breaker Type Thermal
Current Rating 15A
Voltage Rating - AC 250V
Voltage Rating - DC 32V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Illumination None
Product Status Active
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected

Substitute Part Grouping Explanation

Substitute parts for the CMB-153-11C3B-B-A are qualified based on the following critical parameters that determine functional equivalence:

Mandatory Matching Parameters:

  • Current Rating: 15A
  • Voltage Rating - AC: 250V
  • Mounting Type: Panel Mount
  • Breaker Type: Thermal
  • Actuator Type: Push to Reset
  • Number of Poles: 1
  • Illumination: None

Allowable Variation:

  • Voltage Rating - DC: The main part specifies 32V DC. Substitute parts from OptiFuse (CBW57 series) are rated for 50V DC, which represents a higher voltage capability and remains compatible for applications requiring 32V DC operation.

All substitute parts are manufactured by OptiFuse under the CBW57 series designation and maintain Active product status with ROHS3 compliance and REACH Unaffected status. Approval agencies include cURus, IP 40, SAE J1171, UL 1077, and UL 1500, providing equivalent regulatory coverage to the main part.

Parameter Comparison

Parameter CMB-153-11C3B-B-A CBW57-EJ-15A CBW57-EL4-15A CBW57-ES-15A CBW57-ES-15A-5X CBW57-GS-15A-WB CBW57-HB-15A-P CBW57-HS-15A-5X CBW57-PB-15A CBW57-PB-15A-5X CBW57-PB-15A-WX
Manufacturer Carling Technologies OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse OptiFuse
Current Rating (Amps) 15A 15A 15A 15A 15A 15A 15A 15A 15A 15A 15A
Voltage Rating - AC 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V
Voltage Rating - DC 32V 50V 50V 50V 50V 50V 50V 50V 50V 50V 50V
Mounting Type Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount Panel Mount
Breaker Type Thermal Thermal Thermal Thermal Thermal Thermal Thermal Thermal Thermal Thermal Thermal
Actuator Type Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset Push to Reset
Number of Poles 1 1 1 1 1 1 1 1 1 1 1
Illumination None None None None None None None None None None None
Product Status Active Active Active Active Active Active Active Active Active Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

All listed substitute parts maintain Active product status and satisfy the core electrical and mechanical requirements of the CMB-153-11C3B-B-A. The OptiFuse CBW57 series components provide equivalent functionality across all critical parameters with the exception of DC voltage rating, where the 50V DC specification exceeds the 32V DC requirement of the main part.

Compliance Considerations:

The main part carries approvals from CE, cUL, TUV, UL1077, and UL1500. Substitute parts carry approvals from cURus, IP 40, SAE J1171, UL 1077, and UL 1500. Both sets of parts maintain ROHS3 compliance and REACH Unaffected status, confirming environmental and regulatory alignment.

Inventory Availability:

The following substitute parts demonstrate highest inventory levels and are suitable for immediate procurement:

  • CBW57-HB-15A-P: 8,822 units
  • CBW57-ES-15A: 3,521 units
  • CBW57-HS-15A-5X: 1,831 units
  • CBW57-PB-15A-5X: 1,862 units

Packaging Considerations:

All substitute parts are supplied in Bulk packaging. The main part packaging designation is listed as hyphen (-), indicating standard industrial packaging. Bulk packaging from OptiFuse is consistent with standard distribution practices for thermal circuit breakers.

Frequently Asked Questions (FAQ)

Q: Can OptiFuse CBW57 series parts directly replace the Carling Technologies CMB-153-11C3B-B-A?

A: Yes. All listed OptiFuse CBW57 parts match the mandatory electrical and mechanical parameters: 15A current rating, 250V AC voltage rating, panel mount configuration, thermal breaker type, push-to-reset actuation, and single-pole design. The 50V DC rating of OptiFuse parts exceeds the 32V DC specification of the main part, providing compatibility for applications operating at or below 32V DC.

Q: What is the significance of the higher DC voltage rating on substitute parts?

A: The OptiFuse CBW57 series is rated for 50V DC compared to the 32V DC rating of the CMB-153-11C3B-B-A. A higher voltage rating indicates the component can safely operate across a broader voltage range. For applications requiring 32V DC operation, the 50V DC-rated substitute parts operate within their specified limits and provide equivalent protection.

Q: Are the approval agencies equivalent between the main part and substitutes?

A: The main part carries CE, cUL, TUV, UL1077, and UL1500 approvals. Substitute parts carry cURus, IP 40, SAE J1171, UL 1077, and UL 1500 approvals. Both sets include UL 1077 and UL 1500 certifications, which are primary standards for thermal circuit breakers. The cURus approval on substitute parts represents combined Canadian and U.S. regulatory recognition. Both configurations satisfy industrial safety requirements.

Q: What does the suffix designation in part numbers (such as -5X, -WB, -P) indicate?

A: Suffix designations in OptiFuse part numbers identify specific connector, terminal, or packaging variations within the CBW57 series. All variants listed maintain identical electrical specifications (15A, 250V AC, 50V DC) and mechanical form factors (panel mount, push-to-reset, single-pole). Suffix variations do not affect functional equivalence for thermal protection applications.

Q: Are all substitute parts in Active product status?

A: Yes. All listed OptiFuse CBW57 substitute parts maintain Active product status, confirming ongoing manufacturer support, availability, and compliance with current standards.

Q: What is the difference between ROHS3 compliance and REACH Unaffected status?

A: ROHS3 Compliant indicates the component meets Restriction of Hazardous Substances Directive requirements, limiting specified hazardous materials in electrical equipment. REACH Unaffected status indicates the component is not subject to REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) restrictions. Both designations confirm environmental and regulatory compliance for industrial applications.

Q: Which substitute part offers the highest inventory availability?

A: CBW57-HB-15A-P provides the highest inventory level at 8,822 units in stock, followed by CBW57-ES-15A with 3,521 units. These parts are suitable for applications requiring immediate or high-volume procurement.

Request Quote (Ships tomorrow)