CLBA-353-NNFNN-B-A Circuit Breaker Equivalent & Substitute Parts

Part Overview

The CLBA-353-NNFNN-B-A is a thermal circuit breaker manufactured by Carling Technologies, designed for panel mount applications. This single-pole breaker provides overcurrent protection at 35A with dual voltage ratings of 250V AC and 32V DC. The push-to-reset actuator enables manual circuit restoration following a thermal trip event. The part maintains Active product status with full compliance to international safety standards including CE, cUL, TUV, UL1077, and UL1500 certifications. Identification of equivalent substitute parts becomes necessary when managing inventory constraints, lead time requirements, or component availability across supply channels while maintaining identical electrical and mechanical performance specifications.

Substiute Parts

CLBA-353-NNFNN-B-A
Carling TechnologiesIn Stock: 1130CLBA-353-NNFNN-B-A Datasheet
CLBA-353-NNFNN-B-A
Current Part
CLB-353-27E3N-W-A/35
Carling TechnologiesIn Stock: 1728CLB-353-27E3N-W-A/35 Datasheet
CLB-353-27E3N-W-A/35
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Carling Technologies
Series CLB
Breaker Type Thermal
Current Rating 35A
Voltage Rating - AC 250V
Voltage Rating - DC 32V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Illumination None
Product Status Active
RoHS Status ROHS3 Compliant
Approval Agencies CE, cUL, TUV, UL1077, UL1500

Substitute Part Grouping Explanation

Substitution eligibility for the CLBA-353-NNFNN-B-A is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute part CLB-353-27E3N-W-A/35 qualifies as a direct equivalent based on the following matching criteria:

Electrical Parameters (Must Match Exactly):

  • Current Rating: 35A
  • Voltage Rating AC: 250V
  • Voltage Rating DC: 32V
  • Breaker Type: Thermal
  • Number of Poles: 1

Mechanical Parameters (Must Match Exactly):

  • Mounting Type: Panel Mount
  • Actuator Type: Push to Reset
  • Series: CLB

Compliance Parameters (Must Match Exactly):

  • Approval Agencies: CE, cUL, TUV, UL1077, UL1500
  • RoHS Status: ROHS3 Compliant
  • REACH Status: REACH Unaffected

Both parts originate from the same manufacturer (Carling Technologies) and maintain identical functional specifications, ensuring direct interchangeability in circuit protection applications.

Parameter Comparison

Parameter CLBA-353-NNFNN-B-A CLB-353-27E3N-W-A/35 Match Status
Manufacturer Carling Technologies Carling Technologies Identical
Series CLB CLB Identical
Breaker Type Thermal Thermal Identical
Current Rating (Amps) 35A 35A Identical
Voltage Rating - AC 250V 250V Identical
Voltage Rating - DC 32V 32V Identical
Mounting Type Panel Mount Panel Mount Identical
Actuator Type Push to Reset Push to Reset Identical
Number of Poles 1 1 Identical
Illumination None None Identical
Product Status Active Active Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Approval Agencies CE, cUL, TUV, UL1077, UL1500 CE, cUL, TUV, UL1077, UL1500 Identical
REACH Status REACH Unaffected REACH Unaffected Identical

Engineering Selection Recommendations

Both the CLBA-353-NNFNN-B-A and CLB-353-27E3N-W-A/35 maintain Active product status with full compliance to all specified international safety standards. The parts are functionally equivalent across all electrical ratings, mechanical configurations, and regulatory certifications. Selection between these parts is based on inventory availability and supply chain considerations rather than technical performance differentiation. The CLB-353-27E3N-W-A/35 currently maintains higher inventory levels (1661 pieces) compared to the CLBA-353-NNFNN-B-A (1065 pieces), which may influence procurement decisions for high-volume applications. Both parts satisfy ROHS3 compliance requirements and carry identical approval designations from CE, cUL, TUV, UL1077, and UL1500 authorities.

Frequently Asked Questions (FAQ)

Q: Can CLB-353-27E3N-W-A/35 be used as a direct replacement for CLBA-353-NNFNN-B-A?

A: Yes. Both parts are identical in all critical electrical parameters (35A, 250V AC, 32V DC), mechanical configuration (panel mount, push-to-reset), and regulatory compliance. Direct substitution is supported without circuit modification.

Q: Are there differences in thermal trip characteristics between these parts?

A: No differences are specified in the provided parameters. Both parts are classified as thermal breakers with identical current ratings and voltage specifications.

Q: What is the significance of the different part number designations?

A: The part numbers reflect different internal manufacturing codes or packaging variants within the Carling Technologies CLB series. The electrical and mechanical specifications remain identical, confirming functional equivalence.

Q: Do both parts carry the same regulatory certifications?

A: Yes. Both parts hold identical approval designations: CE, cUL, TUV, UL1077, and UL1500. Both are ROHS3 compliant and REACH unaffected.

Q: Is there a preferred part for new designs?

A: Selection is based on availability and supply chain factors. Both parts maintain Active product status and are suitable for new applications. Current inventory levels should be evaluated for procurement planning.

Q: Are there any packaging or MSL (Moisture Sensitivity Level) considerations?

A: Both parts are supplied in bulk packaging. The CLB-353-27E3N-W-A/35 specifies MSL 1 (Unlimited), indicating no moisture sensitivity restrictions during storage or handling.

Request Quote (Ships tomorrow)