The CHS-UPR is an active humidity sensor manufactured by TDK Corporation, designed for analog voltage output applications requiring 5V supply operation. This through-hole mounted sensor delivers 500mV output at 50% relative humidity with ±3% RH accuracy across the 5–95% RH measurement range and 60-second response time. The sensor operates within 0°C to 50°C and is ROHS3 compliant. Finding equivalent substitute parts is necessary to ensure design flexibility, manage supply chain continuity, and maintain component availability across production cycles.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Sensor Type | Humidity |
| Humidity Range | 5 – 95% RH |
| Output Type | Analog Voltage |
| Output | 500mV @ 50%RH |
| Accuracy | ±3% RH |
| Response Time | 60 s |
| Voltage – Supply | 4.75V – 5.25V |
| Mounting Type | Through Hole |
| Operating Temperature | 0°C – 50°C |
| Package / Case | Housed Sensor |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
The CHS-UPS qualifies as a parametric equivalent to the CHS-UPR based on identical electrical and mechanical specifications. Substitution is valid when the following criteria are met:
- Humidity measurement range: 5–95% RH
- Output type: Analog voltage with 500mV @ 50%RH
- Accuracy tolerance: ±3% RH
- Response time: 60 seconds
- Supply voltage range: 4.75V–5.25V
- Mounting configuration: Through hole
- Operating temperature range: 0°C–50°C
- Package form: Housed sensor
- Regulatory compliance: ROHS3 compliant
Both parts belong to the TDK CHS series and maintain identical functional and environmental specifications, making them interchangeable at the circuit design and PCB layout level.
Parameter Comparison
| Parameter | CHS-UPR | CHS-UPS | Match |
|---|---|---|---|
| Manufacturer | TDK Corporation | TDK Corporation | ✓ |
| Series | CHS | CHS | ✓ |
| Product Status | Active | Active | ✓ |
| Sensor Type | Humidity | Humidity | ✓ |
| Humidity Range | 5 – 95% RH | 5 – 95% RH | ✓ |
| Output Type | Analog Voltage | Analog Voltage | ✓ |
| Output | 500mV @ 50%RH | 500mV @ 50%RH | ✓ |
| Accuracy | ±3% RH | ±3% RH | ✓ |
| Response Time | 60 s | 60 s | ✓ |
| Voltage – Supply | 4.75V – 5.25V | 4.75V – 5.25V | ✓ |
| Mounting Type | Through Hole | Through Hole | ✓ |
| Operating Temperature | 0°C – 50°C | 0°C – 50°C | ✓ |
| Package / Case | Housed Sensor | Housed Sensor | ✓ |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ✓ |
| ECCN | EAR99 | EAR99 | ✓ |
| HTSUS | 9025.80.1000 | 9025.80.1000 | ✓ |
Engineering Selection Recommendations
Both CHS-UPR and CHS-UPS are active products with identical electrical performance, environmental ratings, and regulatory compliance status. Selection between these parts should be based on:
- Inventory availability and lead time requirements
- Supply chain logistics and procurement cost
- Design documentation and qualification history within your organization
The CHS-UPS currently maintains higher inventory levels (1565 pcs vs. 1011 pcs), which may provide supply chain advantages for high-volume production or time-sensitive applications. Both parts carry ROHS3 compliance and EAR99 export classification, ensuring regulatory alignment for standard commercial applications.
Frequently Asked Questions (FAQ)
Q: Can CHS-UPS be used as a direct replacement for CHS-UPR in existing designs?
A: Yes. Both parts are parametrically identical across all electrical, mechanical, and environmental specifications. No circuit modifications or PCB layout changes are required for substitution.
Q: Are there any differences in pin configuration or mechanical mounting between these parts?
A: No. Both parts use identical through-hole mounting and housed sensor packaging. Pin-to-pin compatibility is guaranteed.
Q: Do both parts meet the same regulatory requirements?
A: Yes. Both CHS-UPR and CHS-UPS are ROHS3 compliant and classified as EAR99 for export purposes. REACH status for CHS-UPS is listed as unaffected, maintaining compliance with international environmental standards.
Q: What is the basis for substitution between these parts?
A: Substitution is based on matching humidity range (5–95% RH), analog voltage output (500mV @ 50%RH), accuracy (±3% RH), response time (60 s), supply voltage (4.75V–5.25V), operating temperature (0°C–50°C), and through-hole mounting configuration.
Q: Are there any performance differences in accuracy or response time?
A: No. Both parts deliver identical accuracy of ±3% RH and response time of 60 seconds across the full operating temperature range.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts