Equivalent & Substitute Parts Reference for CDZFHT2RA22B

Part Overview

Rohm Semiconductor’s CDZFHT2RA22B is a Zener Diode in the Diodes, Zener category featuring a nominal zener voltage of 22 V, maximum power dissipation of 100 mW, and supplied in a VMN2 (SOD-923) surface mount package. The device is automotive grade, AEC-Q101 qualified, RoHS3 compliant, and REACH unaffected. The product status is Not For New Designs, requiring engineers to identify suitable equivalents for ongoing or new design requirements.

Substiute Parts

CDZFHT2RA22B
Rohm SemiconductorIn Stock: 8272CDZFHT2RA22B Datasheet
CDZFHT2RA22B
Current Part
CDZVT2R22B
Rohm SemiconductorIn Stock: 5312CDZVT2R22B Datasheet
CDZVT2R22B
Parametric Equivalent

Key Parameters

Parameter Main Part Substitute Part
Manufacturer Part Number CDZFHT2RA22B CDZVT2R22B
Manufacturer Rohm Semiconductor Rohm Semiconductor
Category Diodes, Zener Diodes, Zener
Voltage - Zener (Nom) (Vz) 22 V 22 V
Tolerance ±2.11% ±2.11%
Power - Max 100 mW 100 mW
Impedance (Max) (Zzt) 100 Ohms 100 Ohms
Current - Reverse Leakage @ Vr 100 nA @ 17 V 100 nA @ 17 V
Operating Temperature (TJ) 150°C 150°C
Mounting Type Surface Mount Surface Mount
Package / Supplier Device Package VMN2 (SOD-923) VMN2M (SOD-923)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Automotive Grade / Qualification AEC-Q101

Substitute Part Grouping Explanation

Substitution is based strictly on matching the following key electrical and mechanical parameters: zener voltage (Vz), tolerance, maximum power dissipation, maximum impedance, reverse leakage current, and operating temperature. Mechanical compatibility is confirmed by matching mounting type and surface mount JEDEC package (SOD-923 form factor). Compliance and qualification are limited to the data specified, with both parts provided as RoHS3 compliant and not affected by REACH. Only parameters explicitly provided above are used for part equivalence.

Parameter Comparison

Parameter CDZFHT2RA22B CDZVT2R22B
Voltage - Zener (Nom) (Vz) 22 V 22 V
Tolerance ±2.11% ±2.11%
Power - Max 100 mW 100 mW
Impedance (Max) (Zzt) 100 Ohms 100 Ohms
Current - Reverse Leakage @ Vr 100 nA @ 17 V 100 nA @ 17 V
Operating Temperature (TJ) 150°C 150°C
Mounting Type Surface Mount Surface Mount
Package / Case VMN2 (SOD-923) VMN2M (SOD-923)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

CDZFHT2RA22B is designated Not For New Designs. CDZVT2R22B is indicated as Active. Both parts maintain RoHS3 compliance and are not affected by REACH. Moisture Sensitivity Level for both is 1 (Unlimited). Where automotive grade or AEC-Q101 qualification is required, review of explicit technical documentation may be necessary based on provided input. For ongoing designs, CDZVT2R22B meets the specified electrical and mechanical parameters for direct substitution within the Diodes, Zener category.

Frequently Asked Questions (FAQ)

Q: What core parameters must match for direct substitution between CDZFHT2RA22B and CDZVT2R22B?
A: Zener voltage, tolerance, power rating, maximum impedance, reverse leakage current, operating temperature, mounting type, package, and RoHS/REACH compliance must align.

Q: Are the package types VMN2 (SOD-923) and VMN2M (SOD-923) mechanically compatible?
A: Both are 2-SMD surface mount packages in the same SOD-923 form factor as specified.

Q: Does the substitute part maintain compliance and certification requirements?
A: Both models are RoHS3 compliant and REACH unaffected per provided data. Verification for additional automotive or industry-specific qualifications should be based solely on the input parameters.

Q: Is there any significant difference in electrical performance between the main and substitute part numbers?
A: All listed electrical parameters are equivalent as per the provided specification.

Q: Should additional thermal, qualification, or application reviews be conducted?
A: Selection must adhere only to the parameters listed; additional considerations should be based strictly on provided input.

Request Quote (Ships tomorrow)