Request Quote
(Ships tomorrow)
CDL4U/R Terminal Block Connector - Equivalent & Substitute Parts
Part Overview
The CDL4U/R is a feed-through terminal block connector manufactured by Altech Corporation, designed for 4-position, dual-level electrical connections with screw termination. This component is classified as obsolete, making identification of active equivalent parts essential for ongoing system maintenance and new design implementations. The CDL4U/R accommodates wire gauges from 10-22 AWG (0.5-4mm²) and is rated for 35A at 600V under UL standards, with a polyamide (PA66) nylon insulation body in red.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Altech Corporation |
| Category | Terminal Blocks |
| Type | Feed Through |
| Number of Positions | 4 |
| Number of Levels | 2 |
| Terminal Width | 6.0mm |
| Termination Style | Screw |
| Current Rating (UL) | 35A |
| Voltage Rating (UL) | 600V |
| Wire Gauge Range | 10-22 AWG (0.5-4mm²) |
| Insulation Material | Polyamide (PA66), Nylon 6/6 |
| Color | Red |
| Stripping Length | 9mm |
Substitute Part Grouping Explanation
The CDL4UN/R qualifies as a direct substitute for the CDL4U/R based on the following critical parameters that determine functional equivalence:
- Identical mechanical configuration: 4 positions, 2 levels, 6.0mm terminal width
- Matching termination method: Screw termination
- Compatible wire gauge range: 10-22 AWG (CDL4UN/R supports 0.2-4mm² versus CDL4U/R's 0.5-4mm², providing broader compatibility)
- Equivalent current rating: 35A UL rating
- Matching voltage rating: 600V UL rating
- Identical insulation material: Polyamide (PA66), Nylon 6/6
- Same color specification: Red
- Identical stripping length: 9mm
The primary distinction is product status: CDL4U/R is obsolete while CDL4UN/R is active, with enhanced compliance certifications (RoHS3 Compliant, REACH Unaffected).
Parameter Comparison
| Parameter | CDL4U/R (Main Part) | CDL4UN/R (Substitute) |
|---|---|---|
| Manufacturer | Altech Corporation | Altech Corporation |
| Product Status | Obsolete | Active |
| Type | Feed Through | Feed Through |
| Number of Positions | 4 | 4 |
| Number of Levels | 2 | 2 |
| Terminal Width | 6.0mm | 6.0mm |
| Termination Style | Screw | Screw |
| Current Rating (IEC) | 32A | 32A |
| Voltage Rating (IEC) | 400V | 800V |
| Current Rating (UL) | 35A | 35A |
| Voltage Rating (UL) | 600V | 600V |
| Wire Gauge Range (AWG) | 10-22 AWG | 10-22 AWG |
| Wire Gauge Range (mm²) | 0.5-4mm² | 0.2-4mm² |
| Insulation Material | Polyamide (PA66), Nylon 6/6 | Polyamide (PA66), Nylon 6/6 |
| Color | Red | Red |
| Stripping Length | 9mm | 9mm |
| Moisture Sensitivity Level | 1 (Unlimited) | Not Applicable |
| RoHS Status | Not specified | RoHS3 Compliant |
| REACH Status | Not specified | REACH Unaffected |
Engineering Selection Recommendations
The CDL4UN/R is the appropriate selection for applications currently using or specifying the CDL4U/R. The substitute part maintains full electrical and mechanical compatibility while offering the following advantages:
- Active product status: Ensures ongoing availability and manufacturer support
- Enhanced regulatory compliance: RoHS3 Compliant and REACH Unaffected certifications meet current environmental and safety standards
- Improved voltage margin (IEC): 800V IEC rating versus 400V on the original part provides additional safety margin in IEC-regulated applications
- Extended wire gauge compatibility: 0.2-4mm² range accommodates smaller gauge conductors compared to the original 0.5-4mm² specification
Both parts share identical UL ratings (35A, 600V) and mechanical dimensions, ensuring direct form-fit-function replacement in existing designs.
Frequently Asked Questions (FAQ)
Q: Can CDL4UN/R be used as a direct replacement for CDL4U/R in existing assemblies?
A: Yes. The CDL4UN/R maintains identical mechanical configuration (4 positions, 2 levels, 6.0mm terminal width), termination method (screw), wire gauge compatibility (10-22 AWG), and UL electrical ratings (35A, 600V). No design modifications are required.
Q: What is the difference in voltage ratings between the two parts?
A: Under IEC standards, CDL4U/R is rated 400V while CDL4UN/R is rated 800V. Both parts maintain identical 600V UL ratings. The IEC voltage difference does not affect UL-compliant applications.
Q: Does the wire gauge range difference affect compatibility?
A: The CDL4UN/R supports 0.2-4mm² versus CDL4U/R's 0.5-4mm². This represents an expansion of the lower gauge limit, providing broader wire accommodation. Existing applications using 0.5-4mm² wire remain fully compatible.
Q: What packaging differences exist between these parts?
A: CDL4U/R packaging is not specified in available documentation. CDL4UN/R is supplied in bulk packaging. Verify packaging requirements for your procurement process.
Q: Are there compliance or certification differences?
A: CDL4UN/R carries RoHS3 Compliance and REACH Unaffected certifications. CDL4U/R compliance status is not specified. Both parts carry identical ECCN (EAR99) and HTSUS (8536.90.4000) classifications.
Q: Why is CDL4U/R listed as obsolete?
A: Obsolete status indicates the manufacturer has discontinued active production. CDL4UN/R represents the current active equivalent, ensuring access to new inventory and ongoing technical support.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts