CD5CC100JO3F Equivalent & Substitute Parts

Part Overview

The CD5CC100JO3F is a 10 pF mica capacitor manufactured by Cornell Dubilier Electronics (CDE) in the CD5 series. This through-hole radial component operates at 300 V rated voltage with ±5% tolerance and is designed for general-purpose applications. The part is currently active in production status and maintains full RoHS3 compliance with unlimited moisture sensitivity rating (MSL 1).

Substitute parts are identified when equivalent electrical and mechanical parameters are maintained across the same product category, enabling direct replacement in circuit designs while preserving performance specifications.

Substiute Parts

CD5CC100JO3F
Cornell Dubilier Electronics (CDE)In Stock: 1076CD5CC100JO3F Datasheet
CD5CC100JO3F
Current Part
CD5CC100JO3
Cornell Dubilier Electronics (CDE)In Stock: 1026CD5CC100JO3 Datasheet
CD5CC100JO3
Parametric Equivalent

Key Parameters

Parameter Value
Capacitance 10 pF
Tolerance ±5%
Voltage - Rated 300 V
Dielectric Material Mica
Mounting Type Through Hole
Package / Case Radial
Lead Spacing 0.118" (3.00mm)
Operating Temperature Range -55°C ~ 125°C
Size / Dimension 0.272" L x 0.110" W (6.90mm x 2.80mm)
Height - Seated (Max) 0.189" (4.80mm)

Substitute Part Grouping Explanation

Substitution eligibility for the CD5CC100JO3F is determined by strict equivalence across the following critical parameters:

Electrical Parameters: Capacitance value (10 pF), tolerance (±5%), and rated voltage (300 V) must be identical. The mica dielectric material is mandatory for this product category.

Mechanical Parameters: Mounting type (through hole), package configuration (radial), lead spacing (0.118" / 3.00mm), and physical dimensions must match exactly to ensure PCB compatibility without layout modifications.

Environmental Parameters: Operating temperature range (-55°C ~ 125°C) must be maintained.

The CD5CC100JO3 qualifies as a parametric equivalent based on these criteria. Compliance status differences do not affect electrical or mechanical substitution eligibility.

Parameter Comparison

Parameter CD5CC100JO3F (Main Part) CD5CC100JO3 (Substitute)
Manufacturer Cornell Dubilier Electronics (CDE) Cornell Dubilier Electronics (CDE)
Series CD5 CD5
Capacitance 10 pF 10 pF
Tolerance ±5% ±5%
Voltage - Rated 300 V 300 V
Dielectric Material Mica Mica
Operating Temperature -55°C ~ 125°C -55°C ~ 125°C
Mounting Type Through Hole Through Hole
Package / Case Radial Radial
Lead Spacing 0.118" (3.00mm) 0.118" (3.00mm)
Size / Dimension 0.272" L x 0.110" W (6.90mm x 2.80mm) 0.272" L x 0.110" W (6.90mm x 2.80mm)
Height - Seated (Max) 0.189" (4.80mm) 0.189" (4.80mm)
Product Status Active Active
RoHS Status ROHS3 Compliant RoHS non-compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) Not Applicable
REACH Status REACH Unaffected REACH Affected
ECCN EAR99 EAR99
HTSUS 8532.29.0020 8532.29.0020

Engineering Selection Recommendations

CD5CC100JO3F (Primary Selection): This part is the preferred choice for new designs and applications requiring full regulatory compliance. It maintains active production status, ROHS3 compliance, and REACH unaffected classification. The unlimited MSL rating (1) indicates no moisture sensitivity constraints during storage or handling.

CD5CC100JO3 (Alternative Selection): This substitute part provides electrical and mechanical equivalence with identical capacitance, voltage rating, tolerance, and physical dimensions. However, it carries RoHS non-compliant status and REACH affected classification. Selection of this part is appropriate only in applications where regulatory compliance requirements do not apply or where legacy system maintenance necessitates matching existing component specifications.

Both parts share identical ECCN (EAR99) and HTSUS (8532.29.0020) classifications for export and tariff purposes.

Frequently Asked Questions (FAQ)

Q: Can CD5CC100JO3 be used as a direct replacement for CD5CC100JO3F in new designs?

A: CD5CC100JO3 provides electrical and mechanical equivalence. However, CD5CC100JO3F is the recommended choice for new designs due to active production status and full RoHS3 compliance. Selection of CD5CC100JO3 depends on specific regulatory and compliance requirements of the application.

Q: Are the physical dimensions identical between these parts?

A: Yes. Both parts share identical dimensions (0.272" L x 0.110" W / 6.90mm x 2.80mm), maximum seated height (0.189" / 4.80mm), and lead spacing (0.118" / 3.00mm). No PCB layout modifications are required for substitution.

Q: What is the difference in compliance status between these parts?

A: CD5CC100JO3F is ROHS3 compliant and REACH unaffected. CD5CC100JO3 is RoHS non-compliant and REACH affected. These differences do not affect electrical performance but impact regulatory eligibility for specific markets and applications.

Q: Do both parts operate across the same temperature range?

A: Yes. Both CD5CC100JO3F and CD5CC100JO3 operate across -55°C to 125°C, ensuring equivalent thermal performance in circuit applications.

Q: What does MSL 1 (Unlimited) mean for CD5CC100JO3F?

A: MSL 1 indicates unlimited moisture sensitivity. The part requires no special moisture control during storage, handling, or assembly processes, simplifying supply chain and manufacturing logistics.