The TDK-Lambda Americas Inc CCP-2412SF is an isolated module DC-DC converter, delivering 10.2W of power at 12V and 850mA output with a 18V–36V input range. It supports ITE (Commercial) applications and features overcurrent protection (OCP). The product's obsolete status necessitates identifying direct substitutes for design continuity, inventory planning, and supply chain assurance.

Substiute Parts

CCP-2412SF
TDK-Lambda Americas IncIn Stock: 1152CCP-2412SF Datasheet
CCP-2412SF
Current Part
CC10-2412SF-E
TDK-Lambda Americas IncIn Stock: 2420CC10-2412SF-E Datasheet
CC10-2412SF-E
MFR Recommended

Key Parameters

Manufacturer Part Number Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Mounting Type Package / Case Size / Dimension Moisture Sensitivity Level (MSL) ECCN HTSUS
CCP-2412SF Isolated Module 1 18V 36V 12V 850mA 10.2 W 500 V ITE (Commercial) -20°C ~ 70°C (With Derating) Through Hole 8-DIP Module 1.79" x 1.38" x 0.33" 1 (Unlimited) EAR99 8504.40.9580

Substitute Part Grouping Explanation

The substitute grouping utilizes only the allowed electrical and mechanical parameters per the product category. The following parameters were used for matching:

  • Type (Isolated Module)
  • Number of Outputs
  • Voltage - Input (Min)
  • Voltage - Input (Max)
  • Voltage - Output 1 (range or fixed value)
  • Current - Output (Max)
  • Power (Watts)
  • Voltage - Isolation
  • Applications
  • Operating Temperature
  • Mounting Type
  • Package / Case
  • Size / Dimension
  • Moisture Sensitivity Level (MSL)
  • Compliance and classification (ECCN, HTSUS)

Substitution is justified solely when the substitute matches or exceeds these specified electrical and mechanical criteria.

Parameter Comparison

Manufacturer Part Number Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Mounting Type Package / Case Size / Dimension Moisture Sensitivity Level (MSL) ECCN HTSUS
CCP-2412SF Isolated Module 1 18V 36V 12V 850mA 10.2 W 500 V ITE (Commercial) -20°C ~ 70°C (With Derating) Through Hole 8-DIP Module 1.79" x 1.38" x 0.33" 1 (Unlimited) EAR99 8504.40.9580
CC10-2412SF-E Isolated Module 1 18V 36V 12~15V 1A 10 W 500 V ITE (Commercial) -40°C ~ 85°C Through Hole 7-DIP Module 1.40" x 0.89" x 0.33" 1 (Unlimited) EAR99 8504.40.9580

Engineering Selection Recommendations

The CCP-2412SF is classified as obsolete. The substitute CC10-2412SF-E is active, RoHS compliant, and REACH unaffected, with unrestricted moisture sensitivity level (MSL 1). Both share EAR99 ECCN and identical HTSUS classification. Substitute selection is based on compliance and certifications as stated, as well as product activestatus and matching electrical/mechanical characteristics per the provided parameters.

Frequently Asked Questions (FAQ)

Q: What determines the suitability of CC10-2412SF-E as a substitute for CCP-2412SF?
A: Suitability is determined by equivalent type (Isolated Module), input and output voltage ranges, output current rating, isolation voltage, mounting type, application, and package considerations.

Q: Are there differences in dimensions or package type between CCP-2412SF and CC10-2412SF-E?
A: Yes, CCP-2412SF uses an 8-DIP Module case (1.79" x 1.38" x 0.33") while CC10-2412SF-E uses a 7-DIP Module case (1.40" x 0.89" x 0.33"). Dimensional compatibility should be verified within the design constraints specified.

Q: Is RoHS or REACH compliance relevant to substitution?
A: Yes. CC10-2412SF-E is RoHS compliant and REACH unaffected as stated, meeting standard requirements for restricted materials.

Q: Does the substitute part cover the same thermal operating range?
A: CC10-2412SF-E provides a wider operating temperature range (-40°C ~ 85°C) compared to CCP-2412SF (-20°C ~ 70°C with derating), allowing broader deployment conditions per provided data.

Q: Should consideration be taken for mounting or package differences?
A: Substitution requires the mounting type (Through Hole) and package/case style (7-DIP vs 8-DIP) to match application and assembly specifications as provided.

Q: Are the electrical performance parameters directly compatible for substitution?
A: Both models support ITE (Commercial) applications, specified input range, and similar output/efficiency characteristics using the provided data.

Request Quote (Ships tomorrow)