CBS70-14-L Equivalent & Substitute Parts

Part Overview

The CBS70-14-L is a copper mechanical lug terminal manufactured by Panduit Corp, designed for grounding applications with wire gauges 2-8 AWG and a 1/4" stud connection. This component is classified as a rectangular lug terminal with non-insulated construction and is currently in active product status with 723 units in stock.

Substitute parts become necessary when the main part reaches end-of-life status, inventory depletion, or when design requirements allow for compatible alternatives that meet the same electrical and mechanical specifications.

Substiute Parts

CBS70-14-L
Panduit CorpIn Stock: 767CBS70-14-L Datasheet
CBS70-14-L
Current Part
CB70-14-CY
Panduit CorpIn Stock: 1203CB70-14-CY Datasheet
CB70-14-CY
MFR Recommended

Key Parameters

Parameter CBS70-14-L
Manufacturer Panduit Corp
Category Terminals
Terminal Type Lug, Grounding
Stud/Tab Size 1/4 Stud
Wire Gauge 2-8 AWG
Tab Thickness 0.080" (2.03mm)
Length - Overall 1.550" (39.37mm)
Width - Outer Edges 0.500" (12.70mm)
Diameter - Ring ID 0.260" (6.60mm)
Diameter - Barrel OD 0.460" (11.68mm)
Contact Material Copper
Insulation Non-Insulated
Termination Screw
Mounting Type Free Hanging (In-Line)
Product Status Active

Substitute Part Grouping Explanation

Substitution eligibility for the CBS70-14-L is determined by the following critical parameters:

  • Stud/Tab Size: Must be 1/4 Stud (mechanical interface requirement)
  • Terminal Type: Must be Lug, Grounding (functional classification)
  • Contact Material: Must be Copper (electrical conductivity requirement)
  • Insulation: Must be Non-Insulated (design specification)
  • Termination Method: Must be Screw (assembly compatibility)
  • Mounting Type: Must be Free Hanging (In-Line) (installation requirement)
  • Wire Gauge Compatibility: Substitute must accommodate the 2-8 AWG range or broader range that includes 2-8 AWG

The substitute part CB70-14-CY meets these criteria with an extended wire gauge range of 2-12 AWG, which encompasses the original specification while providing additional flexibility for higher gauge applications.

Parameter Comparison

Parameter CBS70-14-L CB70-14-CY
Manufacturer Panduit Corp Panduit Corp
Terminal Type Lug, Grounding Lug, Grounding
Stud/Tab Size 1/4 Stud 1/4 Stud
Wire Gauge 2-8 AWG 2-12 AWG
Tab Thickness 0.080" (2.03mm) 0.090" (2.29mm)
Length - Overall 1.550" (39.37mm) 1.550" (39.37mm)
Width - Outer Edges 0.500" (12.70mm) 0.500" (12.70mm)
Contact Material Copper Copper
Insulation Non-Insulated Non-Insulated
Termination Screw Screw
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line)
Product Status Active Obsolete
RoHS Status Not specified ROHS3 Compliant
REACH Status Not specified REACH Affected

Engineering Selection Recommendations

The CB70-14-CY serves as a functional equivalent to the CBS70-14-L for applications within the 2-8 AWG range. Both components share identical stud size, overall length, width, and mounting configuration, ensuring mechanical compatibility in existing designs.

The CB70-14-CY carries ROHS3 compliance and REACH affected status, providing regulatory alignment for applications subject to these requirements. The slightly increased tab thickness (0.090" versus 0.080") represents a minor mechanical enhancement that does not compromise compatibility.

The obsolete status of CB70-14-CY should be considered in long-term supply chain planning. For new designs or applications requiring extended wire gauge support beyond 8 AWG, the CB70-14-CY's 2-12 AWG range offers additional design flexibility within the same mechanical envelope.

Frequently Asked Questions (FAQ)

Q: Can CB70-14-CY be used as a direct replacement for CBS70-14-L in existing assemblies?

A: Yes, for applications using wire gauges 2-8 AWG. Both components share identical stud size (1/4"), overall dimensions (1.550" length, 0.500" width), and mounting configuration. The mechanical interface is fully compatible.

Q: What is the significance of the wire gauge difference (2-8 AWG versus 2-12 AWG)?

A: The CBS70-14-L is specified for 2-8 AWG wire. The CB70-14-CY extends this range to 2-12 AWG. For applications using only 2-8 AWG conductors, both parts perform identically. The extended range in CB70-14-CY does not affect compatibility with smaller gauge wires.

Q: Does the tab thickness difference affect electrical performance?

A: The tab thickness increase from 0.080" to 0.090" is a mechanical enhancement that does not degrade electrical performance. Both components use copper contact material and maintain the same screw termination method.

Q: What packaging is available for these parts?

A: Both CBS70-14-L and CB70-14-CY are supplied in bulk packaging, suitable for high-volume assembly operations.

Q: Are there compliance considerations when substituting these parts?

A: The CB70-14-CY carries ROHS3 compliance and REACH affected status. Applications subject to these regulatory frameworks should confirm that the substitute part meets all applicable requirements for the end application.

Q: Should the obsolete status of CB70-14-CY influence the substitution decision?

A: The obsolete status indicates that CB70-14-CY is no longer in active production. While 1110 units are currently in stock, long-term availability cannot be guaranteed. For new designs or applications requiring extended production runs, alternative active-status components should be evaluated.

Request Quote (Ships tomorrow)