Request Quote
(Ships tomorrow)
CBS1004824 Equivalent & Substitute Parts Engineering Reference
Part Overview
Manufacturer part number CBS1004824 from Cosel USA, Inc. is categorized as an Isolated Module DC-DC Converter, designed to provide a single 24V output at 4.2A from a 36V–76V input range. Its key attributes include remote on/off control, over-current, over-temperature, and over-voltage protection features. This unit is RoHS3 compliant, box-packaged, with through-hole mounting and a 9-DIP module case. The series (CBS, 100W) is now listed as obsolete, making identification of direct substitute or equivalent models a necessity for applications that require continued support, maintenance, or production where the exact device is no longer available.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | CBS1004824 |
| Manufacturer | Cosel USA, Inc. |
| Category | |
| Description | DC DC CONVERTER 24V |
| Detailed Description | Isolated Module DC DC Converter 1 Output 24V 4.2A 36V - 76V Input |
| Part Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 36V |
| Voltage - Input (Max) | 76V |
| Voltage - Output 1 | 24V |
| Current - Output (Max) | 4.2A |
| Voltage - Isolation | 1.5 kV |
| Efficiency | 88% |
| Mounting Type | Through Hole |
| Package / Case | 9-DIP Module |
| Size / Dimension | 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute eligibility for the CBS1004824 DC-DC converter is principally determined by matching the following allowed electrical and mechanical parameters: input voltage range, output voltage and maximum output current, isolation voltage, efficiency, mounting type, package/case dimensions, number of outputs, and compliance requirements. All equivalent and substitute relationships must reference these strict parameters to qualify as acceptable replacements.
Parameter Comparison
No manufacturer-recommended substitute part is specified for CBS1004824. Therefore, parameter comparison cannot be performed as there is no alternate part number provided for analysis.
| Parameter | CBS1004824 | Substitute |
|---|---|---|
| Manufacturer Part Number | CBS1004824 | None Provided |
| Voltage - Input (Min) | 36V | – |
| Voltage - Input (Max) | 76V | – |
| Voltage - Output 1 | 24V | – |
| Current - Output (Max) | 4.2A | – |
| Voltage - Isolation | 1.5 kV | – |
| Efficiency | 88% | – |
| Mounting Type | Through Hole | – |
| Package / Case | 9-DIP Module | – |
| RoHS Status | ROHS3 Compliant | – |
Engineering Selection Recommendations
The CBS1004824 is listed as obsolete. Engineering selection of substitute or equivalent DC-DC converters must align with the documented parameters, specifically input/output voltage, output current, isolation voltage, mounting configuration, package/case size, efficiency, and RoHS3 compliance. No manufacturer-recommended substitute is available for CBS1004824 based on provided input.
Frequently Asked Questions (FAQ)
Q1: What are the critical criteria when selecting a substitute for CBS1004824?
A1: Substitute selection must strictly match input voltage range (36V–76V), output voltage (24V), output current (4.2A), isolation voltage (1.5 kV), efficiency (88%), mounting type (through hole), package/case (9-DIP module), number of outputs (1), and RoHS3 compliance.
Q2: Can a substitute be used if the mounting type or package differs?
A2: Substitute must have the same mounting type (through hole) and package/case (9-DIP module) to ensure compatibility with existing board layouts.
Q3: What compliance certifications must substitutes meet?
A3: Substitute DC-DC converters must be RoHS3 compliant as per the documented parameter.
Q4: Is it required for substitutes to have matching features such as remote on/off and protection options?
A4: Substitute parts must match all allowed features listed in the provided parameters, including remote on/off, OCP, OTP, and OVP.
Q5: Is thermal or environmental performance a factor in substitution?
A5: Substitute must support the same operating temperature range as specified in the provided input (−40°C to 100°C with derating).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts