Part Overview

The Eaton C7024-06 is a 6-circuit barrier block connector with 0.750" (19.05mm) pitch, rated for 115A at 600V, designed for chassis and panel mounting applications. This component features dual-wall barrier construction with stud termination on both top and bottom, accommodating 2-8 AWG wire gauges across 12 wire entry points arranged in 2 rows.

The C7024-06 is classified as obsolete. Identifying equivalent and substitute parts is necessary to maintain system functionality and ensure continued availability for replacement, repair, and new design implementations.

Substiute Parts

C7024-06
Eaton - Bussmann Electrical DivisionIn Stock: 900C7024-06 Datasheet
C7024-06
Current Part
C7024-12
Eaton - Bussmann Electrical DivisionIn Stock: 695C7024-12 Datasheet
C7024-12
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Eaton - Bussmann Electrical Division
Category Terminal Blocks
Terminal Block Type Barrier Block
Pitch 0.750" (19.05mm)
Current Rating 115A
Voltage Rating 600V
Wire Gauge 2-8 AWG
Termination Type Stud (Top and Bottom)
Barrier Type 2 Wall (Dual)
Mounting Type Chassis, Panel
Operating Temperature 130°C
Flammability Rating UL94 V-0
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the C7024-06 is determined by the following critical parameters:

  • Pitch (0.750" / 19.05mm): Physical spacing between circuit positions; must match exactly for mechanical compatibility
  • Termination Type (Stud): Connection method for both top and bottom; must remain consistent
  • Barrier Type (2 Wall / Dual): Electrical isolation configuration; must match for safety and performance
  • Current Rating (115A): Maximum continuous current capacity; substitute must meet or exceed this value
  • Voltage Rating (600V): Maximum operating voltage; substitute must meet or exceed this value
  • Wire Gauge (2-8 AWG): Acceptable conductor sizes; substitute must support this range
  • Mounting Type (Chassis, Panel): Installation method; substitute must support these configurations
  • Operating Temperature (130°C): Maximum ambient temperature rating; substitute must meet or exceed this value
  • Flammability Rating (UL94 V-0): Fire safety certification; substitute must maintain this standard

The C7024-12 shares the same base product family (C7024), manufacturer, pitch, termination type, barrier configuration, electrical ratings, wire gauge compatibility, mounting options, temperature rating, and flammability certification. The primary difference is circuit count (12 vs. 6), which affects application scope but does not prevent substitution in applications requiring higher circuit density.

Parameter Comparison

Parameter C7024-06 (Main Part) C7024-12 (Substitute)
Manufacturer Eaton - Bussmann Electrical Division Eaton - Bussmann Electrical Division
Terminal Block Type Barrier Block Barrier Block
Number of Circuits 6 12
Pitch 0.750" (19.05mm) 0.750" (19.05mm)
Current Rating (Amps) 115A 115A
Voltage Rating 600V 600V
Wire Gauge 2-8 AWG 2-8 AWG
Top Termination Stud Stud
Bottom Termination Stud Stud
Barrier Type 2 Wall (Dual) 2 Wall (Dual)
Mounting Type Chassis, Panel Chassis, Panel
Operating Temperature 130°C 130°C
Flammability Rating UL94 V-0 UL94 V-0
Product Status Obsolete Active

Engineering Selection Recommendations

The C7024-12 is the primary substitute for the obsolete C7024-06. Both components are manufactured by Eaton - Bussmann Electrical Division and share identical electrical ratings (115A, 600V), mechanical specifications (0.750" pitch, dual-wall barrier construction, stud termination), and safety certifications (UL94 V-0, RoHS Compliant).

The C7024-12 maintains active product status, ensuring ongoing availability and supply chain continuity. The increased circuit count (12 vs. 6) provides expanded connectivity capacity within the same physical footprint and electrical performance envelope. Applications originally designed for the C7024-06 can transition to the C7024-12 without modification to electrical parameters, mounting interfaces, or environmental operating conditions.

Frequently Asked Questions (FAQ)

Q: Can the C7024-12 directly replace the C7024-06 in existing installations?

A: Yes. Both components share identical pitch (0.750"), termination type (stud), barrier configuration (dual-wall), electrical ratings (115A, 600V), wire gauge compatibility (2-8 AWG), mounting options (chassis/panel), and operating temperature (130°C). The C7024-12 provides additional circuit capacity without compromising electrical or mechanical compatibility.

Q: What is the primary difference between these two parts?

A: The C7024-06 provides 6 circuits with 12 wire entry points, while the C7024-12 provides 12 circuits with 2 wire entries. Both maintain the same 0.750" pitch and electrical specifications. Circuit count selection depends on application requirements for connection density.

Q: Are there any compliance or certification differences?

A: No. Both parts maintain UL94 V-0 flammability rating and RoHS compliance. The C7024-12 is currently active in production, while the C7024-06 is obsolete.

Q: What wire gauges are supported by the substitute part?

A: The C7024-12 supports 2-8 AWG wire gauges, identical to the C7024-06 specification.

Q: Are mounting interfaces identical between these parts?

A: Yes. Both components support chassis and panel mounting configurations with identical mechanical interfaces and stud termination on top and bottom surfaces.