Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for Littelfuse C106DG (SCR 400V 4A TO225AA)
Part Overview
The Littelfuse C106DG is a sensitive-gate silicon-controlled rectifier (SCR) rated for 400 V, 4 A, housed in a TO-225AA through-hole package. This device is active and compliant with ROHS3 and REACH regulations. When component shortages, discontinuations, or supply chain constraints occur, it is necessary to identify equivalent SCR thyristors that precisely match the specified electrical and mechanical parameters to maintain system reliability and compliance.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Category | Thyristors |
| SCR Type | Sensitive Gate |
| Voltage - Off State | 400 V |
| Voltage - Gate Trigger (Vgt) (Max) | 800 mV |
| Current - Gate Trigger (Igt) (Max) | 200 µA |
| Voltage - On State (Vtm) (Max) | 2.2 V |
| Current - On State (It (AV)) (Max) | 2.55 A |
| Current - On State (It (RMS)) (Max) | 4 A |
| Current - Hold (Ih) (Max) | 3 mA |
| Current - Off State (Max) | 10 µA |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 20A @ 60Hz |
| Operating Temperature | -40°C ~ 110°C |
| Mounting Type | Through Hole |
| Package / Case | TO-225AA, TO-126-3 |
| Supplier Device Package | TO-225AA |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8541.30.0080 |
Substitute Part Grouping Explanation
Substitute identification for the Littelfuse C106DG SCR is based strictly on matching the following key parameters: device category (thyristors), SCR type (sensitive gate), voltage and current ratings, gate trigger specifications, surge capability, operating temperature range, compliance certifications, mounting type, and package compatibility. Only parts conforming to the combination of these electrical and mechanical attributes qualify as direct substitutes.
Parameter Comparison
| Parameter | C106DG (Main) | S4004VS2TP (MFR Recommended) | C106D1G (Parametric Equivalent) |
|---|---|---|---|
| Category | Thyristors | Thyristors | Thyristors |
| SCR Type | Sensitive Gate | Sensitive Gate | Sensitive Gate |
| Voltage - Off State | 400 V | 400 V | 400 V |
| Voltage - Gate Trigger (Vgt) (Max) | 800 mV | 800 mV | 800 mV |
| Current - Gate Trigger (Igt) (Max) | 200 µA | 200 µA | 200 µA |
| Voltage - On State (Vtm) (Max) | 2.2 V | 1.6 V | 2.2 V |
| Current - On State (It (AV)) (Max) | 2.55 A | 2.5 A | 2.55 A |
| Current - On State (It (RMS)) (Max) | 4 A | 4 A | 4 A |
| Current - Hold (Ih) (Max) | 3 mA | 6 mA | 3 mA |
| Current - Off State (Max) | 10 µA | 2 µA | 10 µA |
| Current - Non Rep. Surge 50, 60Hz (Itsm) | 20A @ 60Hz | 25A, 30A | 20A @ 60Hz |
| Operating Temperature | -40°C ~ 110°C | -40°C ~ 110°C | -40°C ~ 110°C |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
All listed SCR thyristor substitutes for C106DG are active, ROHS3 compliant, REACH unaffected, and have a Moisture Sensitivity Level of 1 (Unlimited). Each part aligns with the specified regulatory, compliance, and operational status parameters required for direct engineering selection.
Frequently Asked Questions (FAQ)
Q1: What are the critical substitution criteria for replacing C106DG SCR thyristors?
A1: Substitute parts must match the SCR type (sensitive gate), voltage and current specifications, mounting type, package/case compatibility, and possess equivalent regulatory compliance status.
Q2: Are the package and mounting styles identical across all substitutes?
A2: C106DG and C106D1G share the TO-225AA package and through-hole mounting, ensuring mechanical interchangeability. S4004VS2TP uses the TO-251AA through-hole package, which requires mechanical compatibility verification based on the specified input.
Q3: Do all substitutes maintain compliance with ROHS3 and REACH standards?
A3: All compared parts are ROHS3 compliant and REACH unaffected, satisfying environmental and safety requirements.
Q4: Are substitute parts active and available for immediate use?
A4: Each listed substitute is designated as active and available in inventory according to the provided input.
Q5: What electrical characteristics must match for successful substitution?
A5: Key electrical characteristics for substitution include voltage and current ratings, gate trigger levels, surge current capability, and operating temperature range. Each substitute aligns with these requirements per the supplied data.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts