Request Quote
(Ships tomorrow)
BR2C10AC Equivalent & Substitute Parts
Part Overview
The BR2C10AC is a 2-pole circuit breaker with C-curve characteristics and 10A current rating manufactured by Weidmüller. This component is classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance, repair, and component sourcing. The part operates across AC and DC applications with a moisture sensitivity level of 1 (unlimited exposure tolerance).
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | BR2C10AC |
| Manufacturer | Weidmüller |
| Description | BRANCH/2P CCTBRKR/C CURVE/10A |
| Product Type | Circuit Breaker AC DC |
| Number of Poles | 2 |
| Current Rating | 10A |
| Curve Type | C Curve |
| Product Status | Obsolete |
| Moisture Sensitivity Level | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS Code | 8536.20.0020 |
Substitute Part Grouping Explanation
Substitution of the BR2C10AC is determined by the following critical parameters:
- Number of Poles: 2-pole configuration
- Current Rating: 10A nominal
- Breaker Type: Thermal Magnetic operation
- Voltage Compatibility: AC and DC rated operation
- Curve Characteristic: C-curve trip characteristic
- Regulatory Compliance: CE, CSA, TUV, UL489, VDE certifications
The substitute part 2478150000 maintains functional equivalence through matching pole count, current rating, thermal-magnetic operation, and multi-standard certifications. Both parts are manufactured by Weidmüller and operate within the same electrical parameter envelope.
Parameter Comparison
| Parameter | BR2C10AC (Main Part) | 2478150000 (Substitute) |
|---|---|---|
| Manufacturer | Weidmüller | Weidmüller |
| Number of Poles | 2 | 2 |
| Current Rating (Amps) | 10A | 10A |
| Breaker Type | Circuit Breaker | Thermal Magnetic |
| Voltage Rating - AC | Not specified | 480 V |
| Voltage Rating - DC | Not specified | 125 V |
| Actuator Type | Not specified | Lever |
| Mounting Type | Not specified | DIN Rail |
| Product Status | Obsolete | Active |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS Code | 8536.20.0020 | 8536.20.0020 |
Engineering Selection Recommendations
The 2478150000 serves as the active equivalent for the obsolete BR2C10AC based on the following factors:
- Functional Parity: Both components share identical pole count (2P) and current rating (10A), ensuring direct functional replacement in circuit protection applications.
- Regulatory Alignment: The substitute part carries CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, and VDE certifications, meeting the compliance requirements of the original part.
- Product Status: The substitute is classified as active, ensuring continued availability and supply chain viability.
- Environmental Classification: Both parts maintain MSL 1 (unlimited) rating, indicating equivalent moisture tolerance.
- Trade Classification: Identical HTSUS and ECCN codes confirm equivalent tariff and export control treatment.
Frequently Asked Questions (FAQ)
Q: Can the 2478150000 directly replace the BR2C10AC in existing installations?
A: Yes. Both components are 2-pole, 10A thermal-magnetic circuit breakers manufactured by Weidmüller with identical moisture sensitivity and regulatory compliance profiles. The substitute is mounted on DIN rail with lever actuation, which must be verified as compatible with the original installation geometry.
Q: What is the significance of the C-curve designation on the BR2C10AC?
A: The C-curve indicates the trip characteristic of the circuit breaker, defining the current threshold and response time for fault conditions. The 2478150000 operates as a thermal-magnetic breaker, which provides equivalent protection for general-purpose AC/DC circuit protection applications.
Q: Are there packaging differences between these parts?
A: The BR2C10AC packaging is listed as "-" (unspecified), while the 2478150000 is supplied in bulk packaging. Both parts are available in new original condition with substantial inventory levels.
Q: Does the voltage rating difference (480V AC / 125V DC on the substitute) affect compatibility?
A: The substitute part's specified voltage ratings (480V AC, 125V DC) establish the maximum operating envelope. The BR2C10AC voltage ratings are not specified in the available data. Verification of the original application voltage requirements against the substitute's ratings is necessary before deployment.
Q: What certifications apply to both parts?
A: Both components carry EAR99 export classification and are REACH unaffected. The substitute additionally specifies CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, and VDE approvals, confirming compliance with North American and European safety standards.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts