Request Quote
(Ships tomorrow)
BK1/ABC-12-R Equivalent & Substitute Parts
Part Overview
The BK1/ABC-12-R is a 12 A ceramic cartridge fuse rated for 250 V AC and 125 V DC operation, manufactured by Eaton - Electronics Division. This component is classified as obsolete, requiring identification of active equivalent alternatives for continued system support and procurement. The fuse operates with fast-blow response characteristics and requires a compatible holder (3AB, 3AG format). Substitute parts must maintain identical electrical ratings, mechanical dimensions, and breaking capacity specifications to ensure proper circuit protection without system redesign.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Current Rating | 12 A |
| Voltage Rating - AC | 250 V |
| Voltage Rating - DC | 125 V |
| Fuse Type | Cartridge, Ceramic |
| Response Time | Fast Blow |
| Package / Case | 3AB, 3AG, 1/4" x 1-1/4" (6.35mm x 31.75mm) |
| Mounting Type | Requires Holder |
| Breaking Capacity @ Rated Voltage | 750A AC, 10kA DC |
| DC Cold Resistance | 0.0068 Ohms |
| Approval Agencies | CSA, UL |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the BK1/ABC-12-R are grouped based on strict electrical and mechanical compatibility criteria. All substitute candidates must satisfy the following parameters:
Critical Matching Parameters:
- Current Rating: 12 A (exact match required)
- Voltage Rating - AC: 250 V (exact match required)
- Voltage Rating - DC: 125 V (exact match required)
- Fuse Type: Cartridge, Ceramic (exact match required)
- Response Time: Fast Blow (exact match required)
- Package / Case: 3AB, 3AG, 1/4" x 1-1/4" (exact match required)
- Mounting Type: Requires Holder (exact match required)
Acceptable Variation Parameters:
- Breaking Capacity: Minimum 750A AC and 10kA DC (equal or greater acceptable)
- DC Cold Resistance: Tolerance range 0.0062 - 0.0076 Ohms
- Melting I²t: Tolerance range 129.6 - 570 (variation acceptable within thermal design limits)
- Approval Agencies: CSA and UL required; additional certifications acceptable
- RoHS Status: ROHS3 Compliant or RoHS Compliant acceptable; non-compliant variants listed for reference only
Substitute parts are organized into two categories: Eaton - Electronics Division alternatives (same manufacturer, different series or variant designations) and Littelfuse Inc. alternatives (different manufacturer, equivalent specifications).
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Current (A) | Voltage AC (V) | Voltage DC (V) | Breaking Capacity AC (A) | Breaking Capacity DC (kA) | DC Cold Resistance (Ohms) | Melting I²t | Product Status | RoHS Status | Approval Agencies |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BK1/ABC-12-R | Eaton - Electronics Division | ABC | 12 | 250 | 125 | 750 | 10 | 0.0068 | 133.3 | Obsolete | ROHS3 Compliant | CSA, UL |
| ABC-12-R | Eaton - Electronics Division | ABC | 12 | 250 | 125 | 750 | 10 | 0.0068 | 133.3 | Active | ROHS3 Compliant | CSA, UL |
| BK/ABC-12-R | Eaton - Electronics Division | ABC | 12 | 250 | 125 | 750 | 10 | 0.0068 | 133.3 | Active | ROHS3 Compliant | CSA, UL |
| BK/ABC-12NR | Eaton - Electronics Division | ABC | 12 | 250 | 125 | 750 | 10 | 0.0068 | 133.3 | Active | RoHS Compliant | CSA, UL |
| BK/ABC-B-12 | Eaton - Electronics Division | ABC | 12 | 250 | 125 | 750 | 10 | 0.0068 | 129.6 | Active | RoHS non-compliant | CSA, UL |
| BK/GBB-12-R | Eaton - Electronics Division | GBB | 12 | 250 | 125 | 10000 | 10 | 0.0062 | Not specified | Active | ROHS3 Compliant | CSA, UR |
| GBB-12-R | Eaton - Electronics Division | GBB | 12 | 250 | 125 | 200 | 10 | 0.0062 | Not specified | Active | CSA, UR | |
| 0314012.HXP | Littelfuse Inc. | 314 | 12 | 250 | 125 | 750 | 10 | 0.0076 | 570 | Active | ROHS3 Compliant | CE, CSA, K-MARK, UL |
| 0314012.MXANP | Littelfuse Inc. | 314 | 12 | 250 | 125 | 750 | 10 | 0.0076 | 570 | Active | CE, CSA, K-MARK, UL | |
| 0314012.MXP | Littelfuse Inc. | 314 | 12 | 250 | 125 | 750 | 10 | 0.0076 | 570 | Active | CE, CSA, K-MARK, UL | |
| 0314012.VXP | Littelfuse Inc. | 314 | 12 | 250 | 125 | 750 | 10 | 0.0076 | 570 | Active | CE, CSA, KC, PSE, UL |
Engineering Selection Recommendations
Primary Substitutes (Eaton - Electronics Division):
The BK/ABC-12-R and ABC-12-R are direct functional equivalents to the obsolete BK1/ABC-12-R. Both parts maintain identical electrical specifications, mechanical dimensions, and breaking capacity ratings. BK/ABC-12-R is recommended as the primary substitute due to active product status and ROHS3 compliance. ABC-12-R serves as an alternative with equivalent performance characteristics.
BK/ABC-12NR provides an additional option with active status and RoHS compliance, maintaining all critical electrical parameters. The BK/ABC-B-12 variant is available but carries RoHS non-compliance status, limiting its application in regulated environments.
Secondary Substitutes (Eaton - Electronics Division, GBB Series):
BK/GBB-12-R and GBB-12-R represent alternative series options with enhanced breaking capacity specifications. BK/GBB-12-R provides 10kA AC breaking capacity compared to the original 750A AC specification, offering superior fault protection capability. GBB-12-R delivers 200A AC breaking capacity. Both maintain 10kA DC breaking capacity and ROHS3 compliance. Approval agencies differ (CSA, UR instead of CSA, UL), requiring verification of system certification requirements before substitution.
Cross-Manufacturer Substitutes (Littelfuse Inc., Series 314):
The Littelfuse 0314012.HXP, 0314012.MXANP, 0314012.MXP, and 0314012.VXP fuses provide equivalent electrical and mechanical specifications with active product status and ROHS3 compliance. All four variants maintain 750A AC and 10kA DC breaking capacity. Operating temperature range (-55°C to 125°C) extends beyond the original specification. Littelfuse variants carry expanded approval certifications (CE, CSA, K-MARK, UL for HXP/MXANP/MXP; additional KC and PSE for VXP), supporting broader international applications. DC cold resistance tolerance (0.0076 Ohms) falls within acceptable variation limits.
Selection Criteria:
For direct replacement requiring identical specifications and certifications, select BK/ABC-12-R or ABC-12-R. For applications requiring enhanced breaking capacity, select BK/GBB-12-R. For cross-manufacturer sourcing with extended operating temperature range and international certifications, select any Littelfuse 314 series variant (0314012.HXP, 0314012.MXANP, 0314012.MXP, or 0314012.VXP). Verify system certification requirements and approval agency acceptance before final selection.
Frequently Asked Questions (FAQ)
Q: Can the BK/ABC-12-R directly replace the obsolete BK1/ABC-12-R?
A: Yes. The BK/ABC-12-R maintains identical current rating (12 A), voltage ratings (250 V AC, 125 V DC), fuse type (ceramic cartridge), response time (fast blow), mechanical dimensions (1/4" x 1-1/4"), and breaking capacity (750A AC, 10kA DC). Both require the same holder type (3AB, 3AG). Active product status and ROHS3 compliance support long-term availability.
Q: What is the difference between ABC-12-R and BK/ABC-12-R?
A: Both parts are functionally equivalent with identical electrical and mechanical specifications. The primary difference is packaging designation and inventory availability. ABC-12-R is available in bulk packaging with 983 pieces in stock. BK/ABC-12-R is available in bulk packaging with 2271 pieces in stock. Both carry active product status and ROHS3 compliance.
Q: Are Littelfuse 314 series fuses compatible with the original BK1/ABC-12-R holder?
A: Yes. Littelfuse 0314012.HXP, 0314012.MXANP, 0314012.MXP, and 0314012.VXP maintain identical mechanical dimensions (0.250" Dia x 1.250" L / 6.35mm x 31.75mm) and package format (3AB, 3AG, 1/4" x 1-1/4"). All four variants are compatible with existing 3AB/3AG holders without modification.
Q: What is the significance of the different Littelfuse part number suffixes (HXP, MXANP, MXP, VXP)?
A: The suffixes indicate different packaging or certification variants within the Littelfuse 314 series. All four variants (0314012.HXP, 0314012.MXANP, 0314012.MXP, 0314012.VXP) maintain identical electrical specifications (12 A, 250 V AC, 125 V DC, 750A AC / 10kA DC breaking capacity). 0314012.VXP carries additional international certifications (KC, PSE) beyond the standard CE, CSA, K-MARK, UL approvals. Selection depends on target market and certification requirements.
Q: Can I use BK/GBB-12-R as a substitute if my system requires higher breaking capacity?
A: BK/GBB-12-R provides 10kA AC breaking capacity compared to the original 750A AC specification, offering enhanced fault protection. However, approval agencies differ (CSA, UR instead of CSA, UL). System certification and approval requirements must be verified before substitution. Consult system documentation and certification bodies to confirm compatibility.
Q: What is the difference between ROHS3 Compliant and RoHS Compliant status?
A: ROHS3 Compliant indicates compliance with the latest RoHS 3 directive (2011/65/EU as amended). RoHS Compliant indicates compliance with earlier RoHS standards. Both statuses satisfy RoHS requirements; ROHS3 represents the current regulatory standard. BK/ABC-B-12 carries RoHS non-compliant status and is not recommended for new designs or regulated applications.
Q: Why do Littelfuse fuses show higher melting I²t values (570) compared to Eaton ABC series (133.3)?
A: Melting I²t represents the thermal energy required to melt the fuse element. Higher values indicate different fuse element design and thermal characteristics. Both values fall within acceptable operating parameters for 12 A fast-blow ceramic cartridge fuses. The difference reflects manufacturing design variations between manufacturers. Electrical performance (current rating, voltage rating, breaking capacity, response time) remains identical across all substitutes.
Q: Are there any temperature operating range differences between substitutes?
A: The original BK1/ABC-12-R does not specify operating temperature range. Littelfuse 314 series variants specify -55°C to 125°C operating range, providing extended temperature capability. Eaton ABC and GBB series variants do not specify operating temperature limits. For applications requiring defined temperature performance, Littelfuse variants provide documented specifications.
Q: Can I mix different substitute part numbers in the same system?
A: Yes, provided all selected parts maintain identical electrical specifications (12 A, 250 V AC, 125 V DC, fast-blow response, 750A AC minimum / 10kA DC breaking capacity) and compatible mechanical dimensions (3AB, 3AG, 1/4" x 1-1/4"). System design and circuit protection coordination should be verified to ensure consistent performance across all fuse positions.
Q: What approval agencies are required for my application?
A: Approval requirements depend on system certification and target markets. CSA and UL certifications are standard for North American applications. CE certification is required for European markets. K-MARK, KC, and PSE certifications support Asian markets. Verify your system's certification documentation to determine required approval agencies. All listed substitutes carry CSA and UL certifications. Littelfuse variants provide expanded international certifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts