ARTESYN / Advanced Energy AXA01C36-L is an isolated DC-DC converter module designed for commercial and industrial applications, offering 1 output at 15V, 1.33A, and supporting input voltages from 18V to 75V. The product is active and RoHS compliant, with robust features including remote on/off, overcurrent protection (OCP), and short circuit protection (SCP). The need to identify substitute models arises due to design flexibility, procurement requirements, or stock availability, ensuring compatibility in electrical, mechanical, and regulatory parameters.

Substiute Parts

AXA01C36-L
ARTESYN / Advanced EnergyIn Stock: 973AXA01C36-L Datasheet
AXA01C36-L
Current Part
SKMW20G-15
MEAN WELL USA Inc.In Stock: 970SKMW20G-15 Datasheet
SKMW20G-15
MFR Recommended

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS
AXA01C36-L ARTESYN / Advanced Energy AXA (20W) Active Isolated Module 1 18V 75V 15V 1.33A 20 W 1.5 kV ITE (Commercial) Remote On/Off, OCP, SCP -40°C ~ 85°C 89% Through Hole 6-DIP Module 1.00" L x 1.00" W x 0.40" H RoHS Compliant 1 (Unlimited) EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitution logic is based strictly on matching key allowed parameters for the isolated DC-DC converter module category. Substitute parts must have identical values or compliance in the following: input voltage range, output voltage, output current, power rating, number of outputs, operating temperature, isolation voltage, mounting type, package/case, RoHS status, ECCN, and moisture sensitivity level (MSL). Only parts that conform to these parameters have been included as valid substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS
AXA01C36-L ARTESYN / Advanced Energy Active Isolated Module 1 18V 75V 15V 1.33A 20 W 1.5 kV ITE (Commercial) Remote On/Off, OCP, SCP -40°C ~ 85°C 89% Through Hole 6-DIP Module 1.00" L x 1.00" W x 0.40" H RoHS Compliant 1 (Unlimited) EAR99 8504.40.9580
SKMW20G-15 MEAN WELL USA Inc. Active Isolated Module 1 18V 75V 15V 1.33A 20 W 1.5 kV ITE (Commercial) Remote On/Off, OCP, OVP, SCP, UVLO -40°C ~ 85°C (With Derating) 88% Through Hole 6-DIP Module 1.00" L x 1.00" W x 0.40" H ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580

Engineering Selection Recommendations

Both AXA01C36-L and SKMW20G-15 are active, RoHS-compliant products with matching electrical and mechanical characteristics. Compliance certifications including MSL (1, unlimited), ECCN (EAR99), and RoHS status are present for both models. SKMW20G-15 additionally specifies ROHS3 compliance and REACH unaffected status. Select either part based on documented inventory and compliance parameters provided.

Frequently Asked Questions (FAQ)

Q1: What are the most important parameters for substituting isolated DC-DC converter modules in this category?
A1: Key parameters include input voltage range, output voltage, output current, power rating, isolation voltage, number of outputs, mounting type, package/case, operating temperature, efficiency, RoHS compliance, ECCN, and MSL.

Q2: Do AXA01C36-L and SKMW20G-15 have compatible dimensions and mounting?
A2: Both parts feature 1.00" L x 1.00" W x 0.40" H dimensions and 6-DIP through-hole modules, ensuring mechanical compatibility.

Q3: Are there any differences in protection features between these models?
A3: Both offer remote on/off, overcurrent protection, and short circuit protection. SKMW20G-15 includes additional features such as overvoltage protection (OVP) and undervoltage lockout (UVLO).

Q4: How do compliance and certifications affect substitute selection?
A4: Selection is restricted to parts that are active, RoHS compliant, carry the same ECCN, and are rated with the same MSL. SKMW20G-15 also states ROHS3 and REACH status.

Q5: Is performance affected by substituting SKMW20G-15 for AXA01C36-L?
A5: Efficiency values are 89% for AXA01C36-L and 88% for SKMW20G-15. All other key parameters match, according to the data provided.

Q6: What packaging type should be considered for inventory compatibility?
A6: Both devices are supplied in Tube packaging, with product status Active and equivalent inventory quantities.

Q7: Are there differences in operating temperature?
A7: AXA01C36-L operates between -40°C to 85°C. SKMW20G-15 specifies -40°C to 85°C with derating. Both meet the specified temperature range.