ARTESYN / Advanced Energy AXA01C36-L is an isolated DC-DC converter module designed for commercial and industrial applications, offering 1 output at 15V, 1.33A, and supporting input voltages from 18V to 75V. The product is active and RoHS compliant, with robust features including remote on/off, overcurrent protection (OCP), and short circuit protection (SCP). The need to identify substitute models arises due to design flexibility, procurement requirements, or stock availability, ensuring compatibility in electrical, mechanical, and regulatory parameters.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AXA01C36-L | ARTESYN / Advanced Energy | AXA (20W) | Active | Isolated Module | 1 | 18V | 75V | 15V | 1.33A | 20 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, SCP | -40°C ~ 85°C | 89% | Through Hole | 6-DIP Module | 1.00" L x 1.00" W x 0.40" H | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution logic is based strictly on matching key allowed parameters for the isolated DC-DC converter module category. Substitute parts must have identical values or compliance in the following: input voltage range, output voltage, output current, power rating, number of outputs, operating temperature, isolation voltage, mounting type, package/case, RoHS status, ECCN, and moisture sensitivity level (MSL). Only parts that conform to these parameters have been included as valid substitutes.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AXA01C36-L | ARTESYN / Advanced Energy | Active | Isolated Module | 1 | 18V | 75V | 15V | 1.33A | 20 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, SCP | -40°C ~ 85°C | 89% | Through Hole | 6-DIP Module | 1.00" L x 1.00" W x 0.40" H | RoHS Compliant | 1 (Unlimited) | EAR99 | 8504.40.9580 |
| SKMW20G-15 | MEAN WELL USA Inc. | Active | Isolated Module | 1 | 18V | 75V | 15V | 1.33A | 20 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP, UVLO | -40°C ~ 85°C (With Derating) | 88% | Through Hole | 6-DIP Module | 1.00" L x 1.00" W x 0.40" H | ROHS3 Compliant | 1 (Unlimited) | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Both AXA01C36-L and SKMW20G-15 are active, RoHS-compliant products with matching electrical and mechanical characteristics. Compliance certifications including MSL (1, unlimited), ECCN (EAR99), and RoHS status are present for both models. SKMW20G-15 additionally specifies ROHS3 compliance and REACH unaffected status. Select either part based on documented inventory and compliance parameters provided.
Frequently Asked Questions (FAQ)
Q1: What are the most important parameters for substituting isolated DC-DC converter modules in this category?
A1: Key parameters include input voltage range, output voltage, output current, power rating, isolation voltage, number of outputs, mounting type, package/case, operating temperature, efficiency, RoHS compliance, ECCN, and MSL.
Q2: Do AXA01C36-L and SKMW20G-15 have compatible dimensions and mounting?
A2: Both parts feature 1.00" L x 1.00" W x 0.40" H dimensions and 6-DIP through-hole modules, ensuring mechanical compatibility.
Q3: Are there any differences in protection features between these models?
A3: Both offer remote on/off, overcurrent protection, and short circuit protection. SKMW20G-15 includes additional features such as overvoltage protection (OVP) and undervoltage lockout (UVLO).
Q4: How do compliance and certifications affect substitute selection?
A4: Selection is restricted to parts that are active, RoHS compliant, carry the same ECCN, and are rated with the same MSL. SKMW20G-15 also states ROHS3 and REACH status.
Q5: Is performance affected by substituting SKMW20G-15 for AXA01C36-L?
A5: Efficiency values are 89% for AXA01C36-L and 88% for SKMW20G-15. All other key parameters match, according to the data provided.
Q6: What packaging type should be considered for inventory compatibility?
A6: Both devices are supplied in Tube packaging, with product status Active and equivalent inventory quantities.
Q7: Are there differences in operating temperature?
A7: AXA01C36-L operates between -40°C to 85°C. SKMW20G-15 specifies -40°C to 85°C with derating. Both meet the specified temperature range.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts