Equivalent & Substitute Parts for ASA00B36-L

Part Overview

The ARTESYN / Advanced Energy ASA00B36-L is an isolated DC DC converter module providing 12V output at up to 500mA from an input range of 18V to 75V, with a maximum power output of 6W. It features single output, through-hole mounting, and a package size of 8-DIP Module (1.25" × 0.80" × 0.40"). This part is classified as obsolete, making it necessary to identify direct alternatives with fully matching electrical, mechanical, and compliance characteristics to ensure uninterrupted application performance.

Substiute Parts

ASA00B36-L
ARTESYN / Advanced EnergyIn Stock: 1569ASA00B36-L Datasheet
ASA00B36-L
Current Part
ASA00B36-LS
ARTESYN / Advanced EnergyIn Stock: 1615ASA00B36-LS Datasheet
ASA00B36-LS
Direct

Key Parameters

ParameterValue
Manufacturer Part NumberASA00B36-L
ManufacturerARTESYN / Advanced Energy
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)18V
Voltage - Input (Max)75V
Voltage - Output 112V
Current - Output (Max)500mA
Power (Watts)6 W
Voltage - Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 71°C
Efficiency81%
Mounting TypeThrough Hole
Package / Case8-DIP Module
Size / Dimension1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm)
Moisture Sensitivity Level (MSL)1 (Unlimited)

Substitute Part Grouping Explanation

Substitution is determined by strictly matching key electrical, mechanical, and compliance parameters. Allowed substitute parts must provide:

  • Identical output voltage and current ratings
  • Matching input voltage range
  • Equivalent isolation voltage
  • Same number of outputs and type (Isolated Module)
  • Identical package and mechanical dimensions
  • Matching operating temperature range and efficiency
  • Consistent mounting type, features, and application suitability
  • Same or stricter compliance regarding Moisture Sensitivity Level

These criteria ensure direct compatibility without alterations in application deployment or performance.

Parameter Comparison

Parameter Main Part: ASA00B36-L Substitute: ASA00B36-LS
ManufacturerARTESYN / Advanced EnergyARTESYN / Advanced Energy
DescriptionDC DC CONVERTER 12V 6WDC DC CONVERTER 12V 6W
TypeIsolated ModuleIsolated Module
Number of Outputs11
Voltage - Input (Min)18V18V
Voltage - Input (Max)75V75V
Voltage - Output 112V12V
Current - Output (Max)500mA500mA
Power (Watts)6 W6 W
Voltage - Isolation1.5 kV1.5 kV
ApplicationsITE (Commercial)ITE (Commercial)
FeaturesSCPSCP
Operating Temperature-40°C ~ 71°C-40°C ~ 71°C
Efficiency81%81%
Mounting TypeThrough HoleThrough Hole
Package / Case8-DIP Module8-DIP Module
Size / Dimension1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm)1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm)
Moisture Sensitivity Level (MSL)1 (Unlimited)1 (Unlimited)
Product StatusObsoleteActive

Engineering Selection Recommendations

The ASA00B36-LS offers an identical electrical, mechanical, and compliance profile compared to the ASA00B36-L, with active product status and RoHS3 compliance. Selection of ASA00B36-LS is valid when ongoing product support, availability, and regulatory compliance are required, particularly for new or current designs where end-of-life risk must be minimized.

Frequently Asked Questions (FAQ)

Q1: What criteria must a substitute for ASA00B36-L meet?
A1: The substitute must match all key electrical parameters (input/output voltage, current, power), mechanical dimensions and mounting, package type, thermal characteristics, and compliance standards.

Q2: Is the ASA00B36-LS mechanically interchangeable with ASA00B36-L?
A2: Yes, both use the 8-DIP Module through-hole package with identical size and pinout.

Q3: Are there any differences in output or input specifications?
A3: No, both parts provide the same 12V output at 500mA, operate from 18V–75V input, and have 1.5 kV isolation.

Q4: Does the substitute meet current compliance standards?
A4: Yes, the ASA00B36-LS is RoHS3 compliant and has the same Moisture Sensitivity Level (MSL 1 Unlimited).

Q5: Are thermal and efficiency specifications maintained in the substitute?
A5: Yes, both parts are rated for -40°C to 71°C operation and have 81% efficiency.

Q6: Should the mounting footprint or PCB design be revised?
A6: No changes to PCB layout are required due to identical mechanical package and pin arrangement.

Request Quote (Ships tomorrow)