Part Overview

The AS1909C20-T is a single-channel power supply supervisor IC manufactured by ams-OSRAM USA INC. in the SOT-23-3 surface mount package. This device functions as a simple reset/power-on reset controller with open drain or open collector output, monitoring a single voltage rail at a 2V threshold with a 100ms minimum reset timeout.

The AS1909C20-T is classified as obsolete. Identifying equivalent substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing production requirements for applications utilizing this supervisor topology.

Substiute Parts

AS1909C20-T
ams-OSRAM USA INC.In Stock: 878AS1909C20-T Datasheet
AS1909C20-T
Current Part
MAX6334UR20D3+T
Analog Devices Inc./Maxim IntegratedIn Stock: 1251MAX6334UR20D3+T Datasheet
MAX6334UR20D3+T
Parametric Equivalent

Key Parameters

Parameter Value
Category Power Management (PMIC)
Type Simple Reset/Power-On Reset
Number of Voltages Monitored 1
Voltage - Threshold 2V
Output Configuration Open Drain or Open Collector
Reset Logic Active Low
Reset Timeout 100ms Minimum
Operating Temperature Range -40°C ~ 125°C (TA)
Mounting Type Surface Mount
Package / Case TO-236-3, SC-59, SOT-23-3
Supplier Device Package SOT-23-3
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the AS1909C20-T is determined by strict equivalence across the following critical parameters:

Functional Parameters:

  • Single voltage monitoring channel
  • 2V threshold voltage
  • Open drain or open collector output topology
  • Active low reset logic
  • 100ms minimum reset timeout

Physical Parameters:

  • SOT-23-3 package (TO-236-3, SC-59)
  • Surface mount configuration

Environmental Parameters:

  • Operating temperature range: -40°C ~ 125°C
  • Moisture sensitivity level: 1 (Unlimited)

The MAX6334UR20D3+T from Analog Devices Inc./Maxim Integrated meets all specified parameters and qualifies as a parametric equivalent. This substitution is based on identical functional specifications, package compatibility, and environmental operating conditions.

Parameter Comparison

Parameter AS1909C20-T MAX6334UR20D3+T
Manufacturer ams-OSRAM USA INC. Analog Devices Inc./Maxim Integrated
Category Power Management (PMIC) Power Management (PMIC)
Type Simple Reset/Power-On Reset Simple Reset/Power-On Reset
Number of Voltages Monitored 1 1
Voltage - Threshold 2V 2V
Output Configuration Open Drain or Open Collector Open Drain or Open Collector
Reset Logic Active Low Active Low
Reset Timeout 100ms Minimum 100ms Minimum
Operating Temperature Range -40°C ~ 125°C (TA) -40°C ~ 125°C (TA)
Mounting Type Surface Mount Surface Mount
Package / Case TO-236-3, SC-59, SOT-23-3 TO-236-3, SC-59, SOT-23-3
Supplier Device Package SOT-23-3 SOT-23-3
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Product Status Obsolete Active

Engineering Selection Recommendations

The MAX6334UR20D3+T is the qualified substitute for the AS1909C20-T based on the following factors:

Product Status: The AS1909C20-T is obsolete, while the MAX6334UR20D3+T maintains active product status with Analog Devices Inc./Maxim Integrated, ensuring ongoing availability and manufacturing support.

Compliance & Certifications: Both parts share identical REACH status (REACH Unaffected), ECCN classification (EAR99), and HTSUS code (8542.39.0001). The MAX6334UR20D3+T carries RoHS3 compliance certification.

Parametric Equivalence: All critical electrical and mechanical parameters are identical, including voltage threshold, output topology, reset timing, operating temperature range, and package configuration.

Supply Chain: The MAX6334UR20D3+T is available in higher inventory quantities (1174 Pcs) compared to remaining AS1909C20-T stock (847 Pcs), supporting long-term production continuity.

Frequently Asked Questions (FAQ)

Q: Can the MAX6334UR20D3+T be used as a direct replacement for the AS1909C20-T?

A: Yes. Both parts are functionally equivalent across all specified parameters: single-channel voltage monitoring at 2V threshold, open drain/open collector output, active low reset logic, 100ms minimum reset timeout, and identical SOT-23-3 package configuration. No circuit modifications are required.

Q: Are there any differences in package handling or moisture sensitivity?

A: No. Both parts are specified with MSL 1 (Unlimited), indicating identical moisture sensitivity levels and handling requirements. Both use the SOT-23-3 package (TO-236-3, SC-59) with surface mount configuration.

Q: What is the primary reason to transition from AS1909C20-T to MAX6334UR20D3+T?

A: The AS1909C20-T is obsolete. The MAX6334UR20D3+T is an active product with ongoing manufacturing support, ensuring supply chain continuity and long-term availability for production requirements.

Q: Are there compliance or certification differences between these parts?

A: Both parts share identical REACH status, ECCN classification, and HTSUS codes. The MAX6334UR20D3+T includes RoHS3 compliance certification, providing additional regulatory alignment for modern manufacturing standards.

Q: What is the operating temperature range for both parts?

A: Both the AS1909C20-T and MAX6334UR20D3+T operate across -40°C to 125°C (TA), supporting identical thermal specifications for industrial and commercial applications.

Request Quote (Ships tomorrow)