A/RH5-CSI-O Equivalent & Substitute Parts

Part Overview

The A/RH5-CSI-O is an active humidity sensor module manufactured by Automation Components, Inc. This chassis-mounted sensor provides analog current and voltage outputs for relative humidity measurement across the 0 to 100% RH range with ±5% accuracy. The product is currently active in production with 1079 units in stock. Substitute parts are identified to support procurement flexibility, inventory management, and supply chain continuity for applications requiring equivalent humidity sensing capabilities.

Substiute Parts

A/RH5-CSI-O
Automation Components, Inc.In Stock: 1091A/RH5-CSI-O Datasheet
A/RH5-CSI-O
Current Part
A/RH5-AN-O
Automation Components, Inc.In Stock: 1133A/RH5-AN-O Datasheet
A/RH5-AN-O
Parametric Equivalent
A/RH5-CP-O
Automation Components, Inc.In Stock: 1092A/RH5-CP-O Datasheet
A/RH5-CP-O
Parametric Equivalent
A/RH5-D
Automation Components, Inc.In Stock: 726A/RH5-D Datasheet
A/RH5-D
Parametric Equivalent
A/RH5-O
Automation Components, Inc.In Stock: 1054A/RH5-O Datasheet
A/RH5-O
Parametric Equivalent
A/RH5-R
Automation Components, Inc.In Stock: 1133A/RH5-R Datasheet
A/RH5-R
Parametric Equivalent
A/RH5-R2
Automation Components, Inc.In Stock: 1137A/RH5-R2 Datasheet
A/RH5-R2
Parametric Equivalent

Key Parameters

Parameter Specification
Sensor Type Humidity
Humidity Range 0 ~ 100% RH
Output Type Analog Current, Analog Voltage
Output Signals 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA
Accuracy ±5% RH
Response Time 20 s
Voltage Supply 18 ~ 28VAC, 12 ~ 40VDC
Operating Temperature -40°C ~ 60°C
Mounting Type Chassis Mount
Package / Case Module
Product Status Active

Substitute Part Grouping Explanation

Substitute parts for the A/RH5-CSI-O are determined by strict parametric equivalence across the following critical specifications:

Core Substitution Criteria:

  • Humidity Range: 0 ~ 100% RH
  • Output Type: Analog Current, Analog Voltage
  • Output Signals: 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA
  • Accuracy: ±5% RH
  • Response Time: 20 s
  • Voltage Supply: 18 ~ 28VAC, 12 ~ 40VDC
  • Mounting Type: Chassis Mount
  • Package / Case: Module
  • Sensor Type: Humidity

All identified substitute parts maintain identical electrical performance and mechanical compatibility with the main part. Variations in operating temperature range and packaging format are noted but do not affect functional substitution within the specified operating envelope of -40°C ~ 60°C.

Parameter Comparison

Part Number Manufacturer Humidity Range Output Type Accuracy Response Time Supply Voltage Operating Temperature Mounting Type Inventory (Pcs) Product Status
A/RH5-CSI-O Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC -40°C ~ 60°C Chassis Mount 1079 Active
A/RH5-AN-O Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC -40°C ~ 60°C Chassis Mount 1067 Active
A/RH5-CP-O Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC -40°C ~ 60°C Chassis Mount 1015 Active
A/RH5-D Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC -40°C ~ 60°C Chassis Mount 661 Active
A/RH5-O Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC 1.5°C ~ 60°C Chassis Mount 1032 Active
A/RH5-R Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC 1.5°C ~ 60°C Chassis Mount 1036 Active
A/RH5-R2 Automation Components, Inc. 0 ~ 100% RH Analog Current, Analog Voltage ±5% RH 20 s 18 ~ 28VAC, 12 ~ 40VDC 1.5°C ~ 60°C Chassis Mount 1124 Active

Engineering Selection Recommendations

All substitute parts listed are active products from Automation Components, Inc. with identical core electrical and mechanical specifications. Selection between the A/RH5-CSI-O and its substitutes should be based on:

Inventory Availability: A/RH5-R2 offers the highest stock level at 1124 units. A/RH5-D has the lowest inventory at 661 units.

Operating Temperature Envelope: The A/RH5-CSI-O, A/RH5-AN-O, and A/RH5-CP-O operate across -40°C ~ 60°C. The A/RH5-O, A/RH5-R, and A/RH5-R2 operate across 1.5°C ~ 60°C. For applications requiring operation below 1.5°C, the A/RH5-CSI-O, A/RH5-AN-O, or A/RH5-CP-O are required.

Packaging Format: The A/RH5-CSI-O is supplied in standard module packaging. All substitute parts are available in Tape & Box (TB) format, which may affect procurement logistics and handling procedures.

All parts maintain identical humidity measurement range, output signal types, accuracy, response time, and supply voltage specifications, ensuring direct functional compatibility within specified operating conditions.

Frequently Asked Questions (FAQ)

Q: Can A/RH5-R2 directly replace A/RH5-CSI-O in all applications?

A: A/RH5-R2 is a parametric equivalent for humidity measurement performance. However, the operating temperature range differs: A/RH5-R2 operates from 1.5°C ~ 60°C while A/RH5-CSI-O operates from -40°C ~ 60°C. Direct replacement is valid only for applications operating above 1.5°C.

Q: What is the difference between the substitute parts?

A: All substitute parts provide identical humidity sensing performance with 0 ~ 100% RH range, ±5% accuracy, and 20 s response time. Differences exist in operating temperature range and packaging format. A/RH5-CSI-O, A/RH5-AN-O, and A/RH5-CP-O support extended low-temperature operation to -40°C. All others operate from 1.5°C minimum.

Q: Are packaging differences significant for substitution?

A: The A/RH5-CSI-O uses standard module packaging. Substitute parts use Tape & Box (TB) format. This affects receiving, storage, and handling procedures but does not impact electrical or mechanical performance. Verify procurement and inventory management compatibility before selection.

Q: Which substitute part has the best availability?

A: A/RH5-R2 has the highest inventory at 1124 units in stock. A/RH5-D has the lowest at 661 units. Inventory levels should be confirmed at time of procurement.

Q: Can I use A/RH5-O as a substitute in a -30°C environment?

A: No. A/RH5-O operates from 1.5°C minimum. For -30°C operation, use A/RH5-CSI-O, A/RH5-AN-O, or A/RH5-CP-O, which are rated to -40°C.

Q: Do all substitute parts support the same output signal options?

A: Yes. All parts provide identical output capability: 0V ~ 5V, 0V ~ 10V, and 4mA ~ 20mA analog signals with ±5% RH accuracy.

Request Quote (Ships tomorrow)