OmniOn Power APTS006A0X-SRDZ is a Non-Isolated PoL Module DC DC Converter with one output, offering an adjustable 0.6–5.5V output voltage at up to 6A and 33W maximum output power. Designed for ITE (Commercial) applications, it features a wide 4.5V to 14V input range, remote on/off, overcurrent protection (OCP), overtemperature protection (OTP), and undervoltage lock out (UVLO). Its mounting type is surface mount in a compact 10-SMD module size. The product status is Obsolete, making the identification of equivalent or substitute parts essential for ongoing designs and maintenance.
Substiute Parts
Key Parameters
| Parameter | APTS006A0X-SRDZ |
|---|---|
| Manufacturer | OmniOn Power |
| Type | Non-Isolated PoL Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 4.5V |
| Voltage - Input (Max) | 14V |
| Voltage - Output 1 | 0.6 ~ 5.5V |
| Current - Output (Max) | 6A |
| Power (Watts) | 33W |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, UVLO |
| Operating Temperature | -40°C ~ 105°C |
| Efficiency | 93.6% |
| Mounting Type | Surface Mount |
| Package / Case | 10-SMD Module |
| Size / Dimension | 0.48" L x 0.48" W x 0.29" H (12.2mm x 12.2mm x 7.3mm) |
| Control Features | Enable, Active Low |
| Moisture Sensitivity Level (MSL) | 2A (4 Weeks) |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Equivalent and substitute parts for DC DC converter modules in this category must align on the following key parameters: input voltage range, output voltage range, number of outputs, maximum output current, mounting type, and package size. Additional required features are remote on/off, OCP, OTP, UVLO, and suitable application (ITE - Commercial). Moisture Sensitivity Level (MSL), operating temperature, and regulatory classifications (ECCN, HTSUS) must match or exceed those of the main part.
Parameter Comparison
| Parameter | APTS006A0X-SRDZ | PJT007A0X3-SRZ |
|---|---|---|
| Manufacturer | OmniOn Power | OmniOn Power |
| Type | Non-Isolated PoL Module | Non-Isolated PoL Module, Digital |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 4.5V | 4.5V |
| Voltage - Input (Max) | 14V | 14.4V |
| Voltage - Output 1 | 0.6 ~ 5.5V | 0.51 ~ 5.5V |
| Current - Output (Max) | 6A | 7A |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, UVLO | Remote On/Off, OCP, OTP, UVLO |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
| Efficiency | 93.6% | 96% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 10-SMD Module | 17-SMD Module |
| Size / Dimension | 0.48" L x 0.48" W x 0.29" H (12.2mm x 12.2mm x 7.3mm) | 0.48" L x 0.48" W x 0.30" H (12.2mm x 12.2mm x 7.5mm) |
| Control Features | Enable, Active Low | Enable, Active Low |
| Moisture Sensitivity Level (MSL) | 2A (4 Weeks) | 2A (4 Weeks) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The APTS006A0X-SRDZ part is classified as Obsolete. PJT007A0X3-SRZ is an Active product from the same manufacturer and is RoHS compliant, with matching compliance certifications (ECCN EAR99, HTSUS 8504.40.9580) and similar environmental specifications (MSL 2A, 4 Weeks). All substitute selection is based strictly on provided product status and regulatory compliance information.
Frequently Asked Questions (FAQ)
Q1: What criteria are used to define an equivalent DC DC converter module substitute?
A1: Substitute modules must match input voltage range, output voltage range, maximum output current, mounting type, features (remote on/off, OCP, OTP, UVLO), application (ITE - Commercial), regulatory certifications, and Moisture Sensitivity Level.
Q2: Are there package and mounting differences that may affect substitution?
A2: Both parts use surface mount technology and have similar footprint and height. The substitute PJT007A0X3-SRZ uses a 17-SMD module with slightly larger height (7.5mm vs. 7.3mm), but maintains the same length and width (12.2mm x 12.2mm).
Q3: How does the substitute part's status affect product lifecycle concerns?
A3: The main part, APTS006A0X-SRDZ, is Obsolete, while the substitute PJT007A0X3-SRZ is Active, ensuring ongoing availability.
Q4: Is there any difference in regulatory compliance between the main and substitute parts?
A4: Both parts have ECCN EAR99 and HTSUS 8504.40.9580 designations and maintain MSL 2A (4 Weeks), providing consistency for compliance and handling.
Q5: Does the substitute part provide equal or greater performance on electrical parameters?
A5: The PJT007A0X3-SRZ offers equal or higher input and output capabilities (current, voltage) based strictly on the provided data.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts