Equivalent & Substitute Parts for ARTESYN AIF04ZPFC-01NL

Part Overview

The ARTESYN / Advanced Energy AIF04ZPFC-01NL is an enclosed AC/DC converter designed for ITE (Commercial) applications. It provides 1 output rated at 380V and 4.2A, supporting up to 1600W continuous power with universal AC input (85 ~ 264 VAC). Its product status is Active. Alternative models are needed for supply chain diversification, risk management, and maintenance of inventory availability without altering the design or mechanical integration.

Substiute Parts

AIF04ZPFC-01NL
ARTESYN / Advanced EnergyIn Stock: 5907AIF04ZPFC-01NL Datasheet
AIF04ZPFC-01NL
Current Part
AIF04ZPFC-01L
ARTESYN / Advanced EnergyIn Stock: 3303AIF04ZPFC-01L Datasheet
AIF04ZPFC-01L
Parametric Equivalent
AIF04ZPFC-01NTL
ARTESYN / Advanced EnergyIn Stock: 942AIF04ZPFC-01NTL Datasheet
AIF04ZPFC-01NTL
Parametric Equivalent
AIF04ZPFC-02NTL
ARTESYN / Advanced EnergyIn Stock: 2253AIF04ZPFC-02NTL Datasheet
AIF04ZPFC-02NTL
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer ARTESYN / Advanced Energy
Series AIF-PFC (1600W)
Type Enclosed
Number of Outputs 1
Voltage - Input 85 ~ 264 VAC
Voltage - Output 1 380V
Current - Output (Max) 4.2A
Power (Watts) 1600 W
Applications ITE (Commercial)
Features Universal Input
Operating Temperature -20°C ~ 100°C
Efficiency 95%
Mounting Type Through Hole
Package / Case 34-DIP Module, 24 Leads
Size / Dimension 4.60" L x 2.40" W x 0.55" H (116.8mm x 61.0mm x 14.0mm)
Approval Agency cUL, TUV, UL
Standard Number 62368-1
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute part selection for the AIF04ZPFC-01NL is strictly determined by matching the manufacturer, output specification, series, enclosure type, input voltage range, output voltage and current, power rating, application, mounting type, package dimension, operating temperature, efficiency, regulatory compliance, and RoHS/Environmental status. Only parts meeting all listed parameters are considered valid for direct substitution.

Parameter Comparison

Parameter AIF04ZPFC-01NL AIF04ZPFC-01L AIF04ZPFC-01NTL AIF04ZPFC-02NTL
Manufacturer ARTESYN / Advanced Energy ARTESYN / Advanced Energy ARTESYN / Advanced Energy ARTESYN / Advanced Energy
Series AIF-PFC (1600W) AIF-PFC (1600W) AIF-PFC (1600W) AIF-PFC (1600W)
Type Enclosed Enclosed Enclosed Enclosed
Number of Outputs 1 1 1 1
Voltage - Input 85 ~ 264 VAC 85 ~ 264 VAC 85 ~ 264 VAC 85 ~ 264 VAC
Voltage - Output 1 380V 380V 380V 380V
Current - Output (Max) 4.2A 4.2A 4.2A 4.2A
Power (Watts) 1600 W 1600 W 1600 W 1600 W
Applications ITE (Commercial) ITE (Commercial) ITE (Commercial) ITE (Commercial)
Features Universal Input Universal Input Universal Input Universal Input
Operating Temperature -20°C ~ 100°C -20°C ~ 100°C -20°C ~ 100°C -20°C ~ 100°C
Efficiency 95% 95% 95% 95%
Mounting Type Through Hole Through Hole Through Hole Through Hole
Package / Case 34-DIP Module, 24 Leads 34-DIP Module, 24 Leads 34-DIP Module, 24 Leads 34-DIP Module, 24 Leads
Size / Dimension 4.60" L x 2.40" W x 0.55" H 4.60" L x 2.40" W x 0.55" H 4.60" L x 2.40" W x 0.55" H 4.60" L x 2.40" W x 0.55" H
Approval Agency cUL, TUV, UL cUL, TUV, UL cUL, TUV, UL cUL, TUV, UL
Standard Number 62368-1 62368-1 62368-1 62368-1
RoHS Status RoHS Compliant RoHS Compliant RoHS Compliant RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
Product Status Active Active Active Active

Engineering Selection Recommendations

For a substitute to AIF04ZPFC-01NL, select only ARTESYN / Advanced Energy AIF-PFC (1600W) series models that are Active, RoHS Compliant, with identical regulatory approvals (cUL, TUV, UL), and certified to standard number 62368-1. Use only devices with Moisture Sensitivity Level (MSL) of 1 (Unlimited), enclosed type, universal input, matching output voltage and current, and the identical mechanical package.

Frequently Asked Questions (FAQ)

Q1: What determines equivalence between AIF04ZPFC-01NL and other models?
A1: Equivalence is determined by matching manufacturer, series, enclosure type, input voltage range, output voltage and current, power rating, application, features, efficiency, mechanical package, approval agency, standard number, RoHS status, and Moisture Sensitivity Level.

Q2: Are mounting and package specifications critical for substitution?
A2: Yes. Substitute units must exactly match the through hole mounting style and the 34-DIP Module, 24 Leads package to ensure correct mechanical and system integration.

Q3: Which compliance and certification criteria are required for substitution?
A3: Substitute parts must be certified to cUL, TUV, UL, and compliant with standard 62368-1 and RoHS requirements.

Q4: Can substitutes with different operating temperature ranges or output parameters be used?
A4: No. Only parts with operating temperature of -20°C ~ 100°C and output parameters of 380V, 4.2A, and 1600 W are valid substitutes.

Q5: What product status must substitute parts have?
A5: Substitute models must have an Active product status.

Q6: Are differences in internal regulatory or accessory features allowed?
A6: Only parameters explicitly provided can be considered. All substitute units must match what is listed above, with no unlisted differences accepted.

Request Quote (Ships tomorrow)