ACS756SCA-100B-PFF-T Current Sensor Equivalent & Substitute Parts

Part Overview

The ACS756SCA-100B-PFF-T is a Hall Effect current sensor manufactured by Allegro MicroSystems, designed for AC/DC current measurement up to 100A in open-loop bidirectional configuration. This component features ratiometric voltage output with 20mV/A sensitivity and operates across a supply voltage range of 3V to 5.5V.

The ACS756SCA-100B-PFF-T is classified as obsolete. Locating equivalent or substitute components is necessary to support ongoing system maintenance, design updates, or production continuity when original inventory becomes unavailable.

Substiute Parts

ACS756SCA-100B-PFF-T
Allegro MicroSystemsIn Stock: 1319ACS756SCA-100B-PFF-T Datasheet
ACS756SCA-100B-PFF-T
Current Part
ACS756SCB-100B-PFF-T
Allegro MicroSystemsIn Stock: 1823ACS756SCB-100B-PFF-T Datasheet
ACS756SCB-100B-PFF-T
Direct

Key Parameters

Parameter Value
Manufacturer Allegro MicroSystems
Current Sensing Range 100A
Sensor Type Hall Effect, Open Loop
Polarization Bidirectional
Output Type Ratiometric, Voltage
Sensitivity 20mV/A
Frequency Range DC ~ 120kHz
Supply Voltage 3V ~ 5.5V
Operating Temperature -20°C ~ 85°C
Mounting Type Through Hole
Package Type 5-CA Formed Leads, PFF
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the ACS756SCA-100B-PFF-T is determined by the following critical parameters:

  • Current sensing capability: 100A
  • Sensor technology: Hall Effect, Open Loop
  • Output configuration: Ratiometric voltage output
  • Sensitivity: 20mV/A
  • Frequency response: DC ~ 120kHz
  • Supply voltage compatibility: 3V ~ 5.5V
  • Operating temperature range: -20°C ~ 85°C
  • Mounting configuration: Through Hole
  • Electrical and mechanical compatibility within the ACS756 product family

The ACS756SCB-100B-PFF-T qualifies as a direct substitute based on identical electrical specifications and functional parameters. The primary difference is the package lead configuration (5-CB versus 5-CA formed leads), which represents a mechanical variation within the same product family while maintaining full electrical equivalence.

Parameter Comparison

Parameter ACS756SCA-100B-PFF-T ACS756SCB-100B-PFF-T
Manufacturer Allegro MicroSystems Allegro MicroSystems
Current Sensing 100A 100A
Sensor Type Hall Effect, Open Loop Hall Effect, Open Loop
Number of Channels 1 1
Output Ratiometric, Voltage Ratiometric, Voltage
Sensitivity 20mV/A 20mV/A
Frequency DC ~ 120kHz DC ~ 120kHz
Linearity ±1.75% ±1.75%
Accuracy ±7% ±7%
Supply Voltage 3V ~ 5.5V 3V ~ 5.5V
Response Time 3µs 3µs
Current Supply (Max) 14mA 14mA
Operating Temperature -20°C ~ 85°C -20°C ~ 85°C
Polarization Bidirectional Bidirectional
Mounting Type Through Hole Through Hole
Package / Case 5-CA Formed Leads, PFF 5-CB Formed Leads, PFF
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL Rating 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
Product Status Obsolete Active

Engineering Selection Recommendations

The ACS756SCB-100B-PFF-T is the qualified substitute for the ACS756SCA-100B-PFF-T based on the following engineering criteria:

Electrical Equivalence: All functional electrical parameters are identical, including current sensing range, output sensitivity, frequency response, supply voltage requirements, and operating temperature specifications.

Compliance Status: Both components maintain ROHS3 compliance and REACH unaffected status, ensuring regulatory alignment for new designs and production environments.

Product Status Advantage: The ACS756SCB-100B-PFF-T carries active product status, providing assured long-term availability and manufacturing support compared to the obsolete ACS756SCA-100B-PFF-T.

Package Compatibility: The mechanical difference between 5-CA and 5-CB formed leads requires PCB layout verification to confirm lead positioning compatibility with existing through-hole footprints. Both configurations maintain identical electrical performance and thermal characteristics.

Frequently Asked Questions (FAQ)

Q: What is the primary difference between ACS756SCA-100B-PFF-T and ACS756SCB-100B-PFF-T?

A: The components are electrically identical. The difference is in the formed lead configuration: 5-CA versus 5-CB. This affects physical lead positioning on the PCB but does not impact electrical function, sensitivity, or performance specifications.

Q: Can I use ACS756SCB-100B-PFF-T as a direct replacement in existing designs?

A: Electrical substitution is valid. However, the formed lead configuration difference requires verification that the PCB through-hole footprint accommodates the 5-CB lead geometry. If the existing PCB is designed specifically for 5-CA leads, mechanical interference may occur.

Q: Are there any compliance or certification differences between these parts?

A: No. Both components maintain identical RoHS3 compliance, REACH unaffected status, MSL rating of 1 (Unlimited), and ECCN/HTSUS classifications.

Q: Why is the ACS756SCA-100B-PFF-T listed as obsolete?

A: Product status reflects Allegro MicroSystems' manufacturing and support decisions. The ACS756SCB-100B-PFF-T, with active status, represents the current production equivalent within the ACS756 family.

Q: What parameters must remain constant for substitution to be valid?

A: Current sensing range (100A), sensor type (Hall Effect, Open Loop), output type (Ratiometric Voltage), sensitivity (20mV/A), frequency response (DC ~ 120kHz), supply voltage (3V ~ 5.5V), and operating temperature range (-20°C ~ 85°C) must all match exactly.

Request Quote (Ships tomorrow)