Weidmüller 991380 Circuit Breaker Thermal Magnetic 8A 480VAC 65VDC Equivalent & Substitute Parts
Part Overview
The Weidmüller 991380 is a three-pole thermal magnetic circuit breaker rated for 8A at 480V AC and 65V DC, designed for DIN rail mounting with lever actuation. This component is classified as obsolete, making identification of active equivalent parts essential for system maintenance and replacement planning. The CB2200 series provides direct functional equivalents that maintain identical electrical and mechanical specifications while offering current product availability.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 8A |
| Voltage Rating - AC | 480V |
| Voltage Rating - DC | 65V |
| Breaker Type | Thermal Magnetic |
| Number of Poles | 3 |
| Mounting Type | DIN Rail |
| Actuator Type | Lever |
| Series | CB2200 |
| Approval Agencies | CSA C22.2 No 235, UL1077, VDE |
Substitute Part Grouping Explanation
Substitution of the Weidmüller 991380 is determined by strict equivalence across all electrical and mechanical parameters. The substitute part 9913800003 qualifies as a direct parametric equivalent because it maintains identical specifications across the following critical criteria:
Current rating of 8A, voltage ratings of 480V AC and 65V DC, three-pole thermal magnetic configuration, lever actuation, DIN rail mounting, and CB2200 series classification. Both parts carry identical regulatory approvals (CSA C22.2 No 235, UL1077, VDE) and RoHS compliance status. The primary distinction is product status: the original part number is obsolete while the substitute is active, and packaging differs (original unspecified versus bulk for the substitute).
Parameter Comparison
| Parameter | 991380 (Original) | 9913800003 (Substitute) |
|---|---|---|
| Manufacturer | Weidmüller | Weidmüller |
| Series | CB2200 | CB2200 |
| Current Rating | 8A | 8A |
| Voltage Rating - AC | 480V | 480V |
| Voltage Rating - DC | 65V | 65V |
| Breaker Type | Thermal Magnetic | Thermal Magnetic |
| Number of Poles | 3 | 3 |
| Mounting Type | DIN Rail | DIN Rail |
| Actuator Type | Lever | Lever |
| Approval Agencies | CSA C22.2 No 235, UL1077, VDE | CSA C22.2 No 235, UL1077, VDE |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Product Status | Obsolete | Active |
| Packaging | Not Specified | Bulk |
Engineering Selection Recommendations
The Weidmüller 9913800003 is the direct substitute for the obsolete 991380 part number. Both components are manufactured by Weidmüller within the CB2200 series and share identical electrical ratings, mechanical configuration, and regulatory certifications. The substitute part maintains active product status with confirmed inventory availability (782 pcs), ensuring supply chain continuity. Selection of part number 9913800003 requires no design modifications, as all functional and compliance parameters remain unchanged. The bulk packaging of the substitute accommodates both single-unit replacement and larger procurement requirements.
Frequently Asked Questions (FAQ)
Q: Can the 9913800003 directly replace the 991380 in existing installations?
A: Yes. Both parts are identical in electrical rating (8A, 480V AC, 65V DC), mechanical configuration (3-pole, lever-actuated, DIN rail mount), and regulatory approval (CSA C22.2 No 235, UL1077, VDE). No circuit modifications or recertification is required.
Q: What is the significance of the product status change from obsolete to active?
A: The original 991380 is no longer manufactured. The 9913800003 is the current production equivalent, ensuring long-term availability and supply chain reliability for replacement and new installations.
Q: Are there packaging considerations when ordering the substitute?
A: The substitute 9913800003 is supplied in bulk packaging, whereas the original packaging specification was not provided. Bulk packaging is standard for industrial circuit breaker distribution and does not affect component performance or installation.
Q: Do both parts carry the same regulatory approvals?
A: Yes. Both the 991380 and 9913800003 are certified to CSA C22.2 No 235, UL1077, and VDE standards. RoHS compliance and REACH unaffected status are identical across both part numbers.
Q: Is there any difference in thermal magnetic trip characteristics between these parts?
A: No differences are specified in the provided parameters. Both parts are classified as thermal magnetic breakers with identical 8A current ratings and identical voltage specifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts