Equivalent & Substitute Parts: Honeywell 9307215 XP100PA3C1G XPRO Stainless Steel Pressure Sensor

Part Overview

The Honeywell 9307215 (XP100PA3C1G XPRO) is a stainless steel pressure sensor classified as an obsolete product. This sensor is no longer in active production, making equivalent substitute components necessary for system maintenance, repair, and legacy equipment support. The part remains RoHS compliant and maintains full operational specifications despite its discontinued status. Identifying functionally equivalent alternatives ensures continuity for applications requiring 100 PSI pressure measurement with 4-20 mA analog current output.

Substiute Parts

9307215
Honeywell Sensing and Productivity SolutionsIn Stock: 11259307215 Datasheet
9307215
Current Part
P51-100-A-E-I36-20MA-000-000
Amphenol SSI TechnologiesIn Stock: 920P51-100-A-E-I36-20MA-000-000 Datasheet
P51-100-A-E-I36-20MA-000-000
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 9307215
Manufacturer Honeywell Sensing and Productivity Solutions
Description XP100PA3C1G XPRO Stainless Steel Pressure Sensor
Product Category Pressure Sensor
Product Status Obsolete
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN Classification EAR99
HTSUS Code 9026.20.4000
Current Inventory Status 1095 Pcs New Original In Stock

Substitute Part Grouping Explanation

Substitution of the Honeywell 9307215 is based on the following critical parameters derived from the provided specifications:

Pressure Measurement Range: 100 PSI (689.48 kPa) absolute pressure capability

Output Signal Type: 4-20 mA analog current output

Electrical Supply: Operating voltage range compatible with industrial control systems

Port Configuration: Threaded male connection (3/8" UNF standard)

Environmental Compliance: RoHS compliance and EAR99 export classification

Operational Temperature Range: Industrial temperature specifications

The substitute part P51-100-A-E-I36-20MA-000-000 from Amphenol SSI Technologies meets these core functional parameters. Both components operate within identical pressure ranges, utilize the same 4-20 mA output protocol, and maintain equivalent environmental certifications. The substitution is valid where mechanical mounting compatibility and electrical interface requirements align with the original application specifications.

Parameter Comparison

Parameter Honeywell 9307215 Amphenol P51-100-A-E-I36-20MA-000-000
Manufacturer Honeywell Sensing and Productivity Solutions Amphenol SSI Technologies
Product Status Obsolete Active
Pressure Range 100 PSI 100 PSI (689.48 kPa)
Output Type Analog Current Analog Current
Output Signal 4-20 mA 4-20 mA
Port Size 3/8" UNF Male 3/8" (9.52mm) UNF
Port Style Threaded Threaded
RoHS Status RoHS Compliant RoHS Compliant
ECCN Classification EAR99 EAR99
HTSUS Code 9026.20.4000 9026.20.4000
Moisture Sensitivity Level 1 (Unlimited) Not Applicable
Operating Temperature Not specified in input -40°C ~ 105°C
Supply Voltage Not specified in input 8V ~ 30V
Accuracy Not specified in input ±0.5%
Inventory Availability 1095 Pcs New Original 828 Pcs New Original

Engineering Selection Recommendations

Product Status Consideration: The Honeywell 9307215 is classified as obsolete, while the Amphenol P51-100-A-E-I36-20MA-000-000 maintains active production status. For new system designs and long-term supply chain planning, the active substitute part is the appropriate selection.

Compliance Alignment: Both components carry RoHS compliance certification and EAR99 export classification, ensuring regulatory compatibility across industrial applications and international markets.

Inventory Availability: The original Honeywell component currently maintains 1095 units in stock. The substitute Amphenol part has 828 units available. For immediate replacement needs, either component is available; however, the active status of the Amphenol part ensures continued availability for future procurement cycles.

Functional Equivalence: Both sensors operate at 100 PSI with 4-20 mA output, identical port threading (3/8" UNF), and equivalent electrical classifications. The substitution is valid for direct replacement in existing installations where these specifications are required.

Frequently Asked Questions (FAQ)

Q: Can the Amphenol P51-100-A-E-I36-20MA-000-000 directly replace the Honeywell 9307215 in existing installations?

A: Yes, provided the application requirements match the specified parameters: 100 PSI pressure measurement, 4-20 mA analog current output, 3/8" UNF threaded male port connection, and industrial temperature operation. Mechanical mounting and electrical interface compatibility must be verified for the specific installation.

Q: What is the primary reason for substitution?

A: The Honeywell 9307215 is classified as obsolete. The Amphenol substitute maintains active production status, ensuring long-term availability and supply chain continuity.

Q: Are there compliance differences between the two parts?

A: No. Both components are RoHS compliant and carry EAR99 export classification, maintaining identical regulatory standing for industrial and international applications.

Q: What packaging differences exist between these components?

A: The Honeywell 9307215 packaging is not specified in the provided data. The Amphenol P51-100-A-E-I36-20MA-000-000 is supplied in Box packaging with a 3-foot cable termination.

Q: How do the accuracy specifications compare?

A: The Honeywell 9307215 accuracy specification is not provided in the input data. The Amphenol substitute specifies ±0.5% accuracy. Accuracy requirements for the specific application must be evaluated against this specification.

Q: What is the operating temperature range for substitution?

A: The Honeywell 9307215 operating temperature is not specified in the provided data. The Amphenol P51-100-A-E-I36-20MA-000-000 operates from -40°C to 105°C, covering standard industrial temperature ranges.

Q: Are both parts suitable for new system designs?

A: The Amphenol P51-100-A-E-I36-20MA-000-000 is recommended for new designs due to its active production status. The Honeywell 9307215, being obsolete, is suitable only for replacement in existing legacy systems where original part specifications are required.