Amphenol ICC 89008-120 Backplane Connector - Equivalent & Substitute Parts

Part Overview

The Amphenol ICC 89008-120 is a 120-position backplane connector header with male pins designed for through-hole PCB mounting. This connector is part of the Metral® series and features press-fit termination with gold-plated contacts rated for 1A current at operating temperatures from -55°C to 125°C.

The 89008-120 is classified as obsolete. Locating active production alternatives is necessary for new designs, ongoing procurement, and long-term supply chain reliability. The substitute part 89008-120LF provides functional equivalence with active product status and improved compliance characteristics.

Substiute Parts

89008-120
Amphenol ICC (FCI)In Stock: 93089008-120 Datasheet
89008-120
Current Part
89008-120LF
Amphenol ICC (FCI)In Stock: 87089008-120LF Datasheet
89008-120LF
Direct

Key Parameters

Parameter Specification
Number of Positions 120
Pitch 0.079" (2.00mm)
Number of Rows 5
Connector Type Header, Male Pins
Mounting Type Through Hole
Termination Press-Fit
Contact Finish Gold, 30.0µin (0.76µm)
Current Rating 1A
Operating Temperature Range -55°C to 125°C
Material Flammability Rating UL94 V-0
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

The 89008-120LF qualifies as a direct substitute for the 89008-120 based on the following matching parameters:

  • Electrical Compatibility: Identical 120-position configuration, 0.079" (2.00mm) pitch, 5-row layout, 1A current rating, and -55°C to 125°C operating temperature range
  • Mechanical Compatibility: Matching through-hole mounting, press-fit termination, and gold contact finish (30.0µin thickness)
  • Series Continuity: Both parts belong to the Amphenol ICC Metral® connector series
  • Certification Alignment: Both maintain UL94 V-0 flammability rating and MSL 1 moisture sensitivity level

The primary distinction is product status and regulatory compliance: the 89008-120LF is active production with RoHS compliance, while the 89008-120 is obsolete and RoHS non-compliant.

Parameter Comparison

Parameter 89008-120 (Main Part) 89008-120LF (Substitute)
Manufacturer Amphenol ICC (FCI) Amphenol ICC (FCI)
Series Metral® Metral®
Number of Positions 120 120
Pitch 0.079" (2.00mm) 0.079" (2.00mm)
Number of Rows 5 5
Connector Type Header, Male Pins Header, Male Pins
Mounting Type Through Hole Through Hole
Termination Press-Fit Press-Fit
Contact Finish Gold, 30.0µin (0.76µm) Gold, 30.0µin (0.76µm)
Current Rating 1A 1A
Operating Temperature -55°C to 125°C -55°C to 125°C
Material Flammability Rating UL94 V-0 UL94 V-0
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
Product Status Obsolete Active
RoHS Status RoHS non-compliant RoHS Compliant
Packaging Not specified Tube

Engineering Selection Recommendations

The 89008-120LF is the appropriate selection for new designs and ongoing applications requiring the 120-position Metral® header configuration. This substitute maintains full electrical and mechanical compatibility while offering two critical advantages:

  1. Active Production Status: The 89008-120LF is in active production, ensuring long-term availability and supply chain continuity compared to the obsolete 89008-120.

  2. Regulatory Compliance: The 89008-120LF meets RoHS compliance requirements, aligning with current environmental and procurement standards. The original 89008-120 does not meet RoHS compliance.

Both parts carry identical certifications (UL94 V-0, MSL 1) and operate within the same electrical and thermal parameters, confirming direct substitution capability.

Frequently Asked Questions (FAQ)

Q: Can the 89008-120LF be used as a direct replacement for the 89008-120 in existing designs?

A: Yes. The 89008-120LF maintains identical electrical specifications (120 positions, 0.079" pitch, 1A rating, -55°C to 125°C operating range), mechanical configuration (through-hole, press-fit termination), and contact properties (gold finish, 30.0µin thickness). PCB layouts and mating interfaces require no modification.

Q: What is the difference between the 89008-120 and 89008-120LF?

A: The primary differences are product status and compliance. The 89008-120 is obsolete and RoHS non-compliant. The 89008-120LF is active production and RoHS compliant. Both parts are functionally equivalent across all electrical and mechanical parameters.

Q: Does the packaging difference affect compatibility?

A: No. The 89008-120LF is supplied in tube packaging, while the 89008-120 packaging is not specified. Packaging affects handling and storage logistics but does not impact electrical or mechanical performance in the application.

Q: Are there any thermal or current rating differences?

A: No. Both parts are rated for 1A current and operate across the identical temperature range of -55°C to 125°C. Thermal and electrical performance characteristics are equivalent.

Q: What certifications apply to both parts?

A: Both the 89008-120 and 89008-120LF carry UL94 V-0 material flammability rating and MSL 1 (Unlimited) moisture sensitivity level. The 89008-120LF additionally meets RoHS compliance requirements.