Qualtek 854-10/018 LINE FILTER 10A CHASSIS MOUNT - Equivalent & Substitute Parts

Part Overview

The Qualtek 854-10/018 is an EMC/EMI line filter rated for 10 A AC applications with chassis mount configuration. This component is classified as Active product status and is ROHS3 compliant. Substitute parts may be required due to inventory constraints, regional availability, or specific application requirements that demand alternative electrical or mechanical specifications within the allowable parameter range for this product category.

Substiute Parts

854-10/018
QualtekIn Stock: 1122854-10/018 Datasheet
854-10/018
Current Part
10ER7
TE Connectivity Corcom FiltersIn Stock: 85310ER7 Datasheet
10ER7
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number 854-10/018
Manufacturer Qualtek
Current Rating 10 A
Mounting Type Chassis Mount
Product Status Active
RoHS Status ROHS3 Compliant
Applications General Purpose
ECCN EAR99

Substitute Part Grouping Explanation

The TE Connectivity Corcom Filters 10ER7 qualifies as a manufacturer-recommended substitute based on the following critical parameters:

  • Current Rating: Both parts are rated for 10 A
  • Mounting Type: Both utilize Chassis Mount configuration
  • Product Status: Both are Active
  • RoHS Compliance: Both are ROHS3 Compliant
  • Applications: Both serve General Purpose applications
  • ECCN Classification: Both are classified as EAR99

The 10ER7 provides additional specifications including rated AC voltage (250V), operating frequency (50/60Hz), and defined operating temperature range (-10°C ~ 40°C), which extend the functional envelope while maintaining core substitution compatibility.

Parameter Comparison

Parameter 854-10/018 (Qualtek) 10ER7 (TE Connectivity Corcom)
Manufacturer Part Number 854-10/018 10ER7
Manufacturer Qualtek TE Connectivity Corcom Filters
Current Rating 10 A 10 A
Voltage - Rated AC Not specified 250V
Frequency - Operating Not specified 50/60Hz
Mounting Type Chassis Mount Chassis Mount
Operating Temperature Not specified -10°C ~ 40°C
Product Status Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
ECCN EAR99 EAR99
Approval Agency Not specified CSA, UR, VDE

Engineering Selection Recommendations

Both the Qualtek 854-10/018 and TE Connectivity Corcom Filters 10ER7 maintain Active product status and ROHS3 compliance. The 10ER7 carries additional third-party certifications (CSA, UR, VDE) and defined electrical parameters (250V AC, 50/60Hz operation), which may be advantageous for applications requiring documented compliance documentation or operation within specified temperature and frequency ranges. Selection between these parts should be based on specific application voltage requirements, regional certification needs, and inventory availability.

Frequently Asked Questions (FAQ)

Q: What are the primary substitution criteria for the 854-10/018?

A: The 10 A current rating and Chassis Mount configuration are the primary substitution criteria. Both the main part and substitute maintain these specifications along with Active product status and ROHS3 compliance.

Q: Does the 10ER7 substitute provide additional electrical specifications?

A: Yes. The 10ER7 includes rated AC voltage (250V), operating frequency (50/60Hz), and operating temperature range (-10°C ~ 40°C), which are not specified for the 854-10/018. These parameters define the functional operating envelope for the substitute part.

Q: Are there compliance differences between these parts?

A: The 10ER7 carries CSA, UR, and VDE certifications, while the 854-10/018 does not list specific approval agencies. Both parts are ROHS3 compliant and classified as EAR99 for export control purposes.

Q: What packaging considerations apply to these parts?

A: The 854-10/018 is supplied in standard packaging, while the 10ER7 is supplied in Bulk packaging. Packaging format should be verified against procurement requirements.

Q: Can the 10ER7 be used in all applications where the 854-10/018 is specified?

A: Substitution compatibility is determined by matching the 10 A current rating, Chassis Mount configuration, and general purpose application classification. The 10ER7's additional specifications (250V AC, 50/60Hz, -10°C ~ 40°C) must align with the target application requirements.

Request Quote (Ships tomorrow)